References
- Liboff A. R., Smith S. D., McLeod B. R. Experimental evidence for ion cyclotron resonance mediation of membrane transport. Mechanistic Approaches to Interactions of Electric and Electromagnetic Fields with Living Systems, M. Blank, E. Findl. Plenum Press, New York 1987; 109–132
- Binghy V. N. On the model: ion channel–electrical solenoid. Biophysics 1995; 40: 549–550
- Lednev V. V. Possible mechanism for the influence of weak magnetic fields on biological systems. Bioelectromagnetics 1991; 12: 71–75
- Chiabrera A., Bianco B., Caufman J. J., Pilla A. A. 1. Quantum dynamics of ions in molecular crevices under electromagnetic exposure; 2. Quantum analysis of ion binding kinetics in electromagnetic bioeffects. Electromagnetics in Medicine and Biology, C. T. Brighton, S. R. Pollack. San Francisco Press, San Francisco 1991; 21–26; 27–31
- Edmonds D. T. Larmor precession as a mechanism for the detection of static and alternating magnetic fields. Bioelectrochem. Bioenerget. 1993; 30: 3–12
- Lednev V. V. Bioeffects of weak combined, static and alternating magnetic fields [in Russian]. Biofizika 1996; 41: 224–232
- Binghy V. N. Nuclear spins in primary mechanisms of biomagnetic effects. Biophysics 1995; 40: 677–691
- Chiabrera A., Bianco B., Moggia E. Effect of lifetimes on ligand binding modeled by the density operator. Bioelectrochem. Bioenerget. 1993; 30: 35–42
- Slichter C. P. Principles of Magnetic Resonance 2nd ed. Springer, Berlin 1978
- Landau L. D., Lifshitz E. M. Quantum Mechanics. Pergamon Press, Oxford 1965
- Binghy V. N. Mechanism for magnetosensitive ion binding with a protein, Biofiz‐ika, (accepted for publication)
- Satyshur K. A., Rao S. T., Pyzalska D., Drendel W., Greaser M., Sundaral‐ingam M. Refined structure of chicken skeletal muscle troponin C in the two‐calcium state at 2‐A resolution. J. Biol. Chem. 1988; 263: 1628–1647
- Alipov Ye. D., Belyaev I. Ya. Difference in frequency spectrum of extremely‐low‐frequency effects on the genom conformational state of AB1157 and EMG2 E. coli cells. Bioelectromagnetics 1996; 17, Abst. of the III Int. Cong. EBEA, Nancy, France, 1996
- Lednev V. V., Srebnitskaya L. K., Ilyasova E. N., Rozhdestvenskaya Z. E., Klimov A. A., Tiras H. P. Weak combined magnetic field set in parametric resonance of nuclear spins of hydrogen atoms increases proliferation of neoblasts in regenerating Planaria [in Russian]. Doklady Akad. Nauk 1996; 348: 830–833
- Prato F. S., Kavaliers M., Carson J. L., Ossenkopp K. P. Magnetic field exposure at 60 Hz attenuates endogenous opioid‐induced analgesia in a land snail consistent with the quantum mechanical predictions of the Lednev model. Abstract A‐l‐1, Fifteenth Annual Meeting of the Bioelectromagnetics Society, Los Angeles, CA, June, 1993
- Chew G. L., Brown G. E. Orientation of rainbow trout (Salmo gairdneri) in normal and null magnetic fields. Can. J. Zool. 1989; 67: 641–643
- Taylor R., Walton D. R.M. The chemistry of fuilernes. Nature 1993; 363: 685–693