- Aldinger PR, Thomsen M, Mau H, Ewerbeck V, Breusch SJ. Cementless Spotorno tapered titanium stems: excellent 10-15-year survival in 141 young patients. Acta Orthop Scand 2003; 74(3):253-8.
- Bobyn JD, Mortimer ES, Glassman AH, Engh CA, Miller JE, Brooks CE. Producing and avoiding stress shielding. Laboratory and clinical observations of noncemented total hip arthroplasty. Clin Orthop 1992; (274):79-96.
- Brodner W, Bitzan P, Lomoschitz F, Krepler P, Jankovsky R, Lehr S, Kainberger F, Gottsauner-Wolf F. Changes in bone mineral density in the proximal femur after cementless total hip arthroplasty. A five-year longitudinal study. J Bone Joint Surg (Br) 2004; 86:20-6.
- Dorr LD, Faugere MC, Mackel AM, Gruen TA, Bognar B, Malluche HH. Structural and cellular assessment of bone quality of proximal femur. Bone 1993; 14:231-42.
- Draenert KD, Draenert YI, Krauspe R, Bettin D. Strain adaptive bone remodelling in total joint replacement. Clin Orthop 2005; (430):12-27.
- Engh CA, Bobyn JD, Glassman AH. Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding, and clinical results. J Bone Joint Surg (Br) 1987; 69:45-55.
- Engh C A Sr, Culpepper W J 2nd. Femoral fixation in primary total hip arthroplasty. Orthopedics 1997; 20(9):771-3.
- Espehaug B, Havelin LI, Engesaeter LB, Langeland N, Vollset SE. Patient-related risk factors for early revision of total hip replacements. A population register-based case-control study of 674 revised hips. Acta Orthop Scand 1997; 68:207-15.
- Freeman M AR, Plante-Bordeneuve P. Early migration and late aseptic failure of proximal femoral prostheses. J Bone Joint Surg (Br) 1994; 76:432-8.
- Furnes O, Lie SA, Espehaug B, Vollset SE, Engesaeter LB, Havelin LI. Hip disease and the prognosis of total hip replacements. A review of 53,698 primary total hip replacements reported to the Norwegian Arthroplasty Register 1987-99. J Bone Joint Surg (Br) 2001; 83:579-86.
- Grübl A, Chiari C, Giurea A, Gruber M, Kaider A, Marker M, Zehetgruber H, Gottsauner-Wolf F. Cementless total hip arthroplasty with the rectangular titanium Zweymuller stem. A concise follow-up, at a minimum of fifteen years, of a previous report. J Bone Joint Surg (Am) 2006; 88(10):2210-5.
- Harris WH. Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg (Am) 1969; 51:737-55.
- Houde J, Marchetti M, Duquette J, Hoffman A, Steinberg G, Crane GK, Baran, D, . Correlation of bone mineral density and femoral neck hardness in bovine and human samples. Calcif Tissue Int 1995; 57:201-5.
- Johnston RC, Fitzgerald R H Jr, Harris WH, Poss R, Muller ME, Sledge CB. Clinical and radiographic evaluation of total hip replacement. A standard system of terminology for reporting results. J Bone Joint Surg (Am) 1990; 72:161-8.
- Kannus P, Jarvinen M, Sievanen H, Oja P, Vuori I. Osteoporosis in men with a history of tibial fracture. J Bone Miner Res 1994; 9:423-9.
- Kobayashi S, Saito N, Horiuchi H, Iorio R, Takaoka, K. Poor bone quality or hip structure as risk factors affecting survival of total-hip arthroplasty. Lancet 2000; 355:1499-504.
- Linder L. Implant stability, histology, RSA and wear: more critical questions are needed: a point of view. Acta Orthop Scand 1994; 65:654-8.
- Mazess RB. On aging bone loss. Clin Orthop 1982; (165):239-52.
- Mjöberg B, Selvik G, Hansson LI, Rosenqvist R, önnerfält R. Mechanical loosening of total hip prostheses: a radiographic and roentgen stereophotogrammetric study. J Bone Joint Surg (Br) 1986, 73: 551-8.
- Mueller LA, Kress A, Nowak T, Pfander D, Pitto RP, Forst R, Schmidt R. Periacetabular bone changes after uncemented total hip arthroplasty evaluated by quantitative computed tomography. Acta Orthop 2006; 77:380-5.
- Nishii T, Sugano N, Masuhara K, Shibuya T, Ochi T, Tamura S. Longitudinal evaluation of time related bone remodeling after cementless total hip arthroplasty. Clin Orthop 1997; 339:121-31.
- Rosenthall L, Bobyn JD, Brooks CE. Temporal changes of periprosthetic bone density in patients with a modular noncemented femoral prosthesis. J Arthroplasty 1999; 14:71-6.
- Santavirta S, Konttinen YT, Bergroth V, Eskola A, Tallroth K, Lindholm TS. Aggressive granulomatous lesions associated with hip arthroplasty. Immunopathological studies. J Bone Joint Surg (Am) 1990; 72:252-8.
- Schimmed JW, Huiskes R. Primary fit of the Lord cementless total hip. Acta Orthop Scand 1988; 59:638-42.
- Schmidt R, Nowak TE, Mueller L, Pitto RP. Osteodensitometry after total hip replacement with uncemented taper-design stem. Int Orthop 2004; 28:74-7.
- Schmidt R, Pitto RP, Kress A, Ehrmann C, Nowak TE, Reulbach U, Forst R, Muller L. Inter- and intraobserver assessment of periacetabular osteodensitometry after cemented and uncemented total hip arthroplasty using computed tomography. Arch Orthop Trauma Surg 2005; 125: 291-7.
- Schramm M, Keck F, Hohmann D, Pitto RP. Total hip arthroplasty using an uncemented femoral component with taper design: outcome at 10-year follow-up. Arch Orthop Trauma Surg 2000; 120:407-12.
- Spotorno L, Romagnoli S, Ivaldo N, Grappiolo G, Bibbiani E, Blaha DJ, Guen TA. The CLS system. Theoretical concept and results. Acta Orthop Belg (Suppl 1) 1993; 59:144-8.
- Taylor M, Tanner KE, Freeman M AR, Yettram AL. Finite element remodelling - predictor of implant survival? J Mat Sci Mat Med 1995a; 6:808-12.
- Taylor M, Tanner KE, Freeman M AR, Yettram AL. Cancellous bone stresses sourrounding the femoral component of a hip prosthesis: an elastic-plastic finite element analysis. Med Eng Phys 1995b; 17:544-50.
- Taylor M, Tanner KE. Topic for debate: Fatigue failure of cancellous bone: a possible cause of implant migration and loosening. J Bone Joint Surg (Br) 1997b; 79:181-2.
- Venesmaa PK, Kroger HP, Miettinen HJ, Jurvelin JS, Suomalainen OT, Alhava EM. Monitoring of periprosthetic BMD after uncemented total hip arthroplasty with dual-energy X-ray absorptiometry--a 3-year follow-up study. J Bone Miner Res 2001; 16:1056-61.
- Willert HG, Bertram H, Buchhorn GH. Osteolysis in alloarthroplasty of the hip. The role of ultra-high molecular weight polyethylene wear particles. Clin Orthop 1990; (258):95-107.
Acta Orthopaedica
Volume 81, 2010 - Issue 2
Open access
887
Views
24
CrossRef citations to date
0
Altmetric
Research Article
Progressive femoral cortical and cancellous bone density loss after uncemented tapered-design stem fixation
A 6-year follow-up
Lutz A Mueller Department of Orthopaedic Surgery, Friedrich Alexander University of Erlangen-Nuremberg, ErlangenCorrespondence[email protected]
, Tobias E Nowak Department of Trauma Surgery, Johannes Gutenberg University, Mainz
, Lothar Haeberle Department of Medical Informatics, Biometry and Epidemiology, Friedrich Alexander University of Erlangen-Nuremberg, Erlangen
, Lars P Mueller Department of Trauma Surgery, Johannes Gutenberg University, Mainz
, Alexander Kress Department of Orthopaedic Surgery, Friedrich Alexander University of Erlangen-Nuremberg, Erlangen
, Michael Voelk Department of Orthopaedic Surgery, Friedrich Alexander University of Erlangen-Nuremberg, Erlangen
, , Raimund Forst Department of Orthopaedic Surgery, Friedrich Alexander University of Erlangen-Nuremberg, Erlangen
& Rainer Schmidt Department of Orthopaedic Surgery, Friedrich Alexander University of Erlangen-Nuremberg, Erlangen
show all
Pages 171-177
|
Received 24 Mar 2009, Accepted 05 Sep 2009, Published online: 29 Jun 2010
Related research
People also read lists articles that other readers of this article have read.
Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.
Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.