911
Views
17
CrossRef citations to date
0
Altmetric
Research Article

Early bone growth on the surface of titanium implants in rat femur is enhanced by an amorphous diamond coating

, , , , , & show all
Pages 499-503 | Received 01 Oct 2010, Accepted 19 Feb 2011, Published online: 20 Apr 2011

  • Aamodt A, Nordsletten L, Havelin LI, Indrekvam K, Utvag SE, Hviding K. Documentation of hip prostheses used in Norway: a critical review of the literature from 1996--2000. Acta Orthop Scand 2004; 75(6):663-76.
  • Bhadang KA, Gross KA. Influence of fluorapatite on the properties of thermally sprayed hydroxyapatite coatings. Biomaterials 2004; 25(20):4935-45.
  • Brånemark R, Öhrnell LO, Nilsson P, Thomsen P. Biomechanical characterization of osseointegration during healing: an experimental in vivo study in the rat. Biomaterials 1997; 18(14):969-78.
  • Ellison B, Cheney NA, Berend KR, Lombardi Jr AV, Mallory TH. Minimal stress shielding with a Mallory-Head titanium femoral stem with proximal porous coating in total hip arthroplasty. J Orthop Surg Res 2009; 4:42.
  • Emerson RH, Jr., Head WC, Emerson CB, Rosenfeldt W, Higgins LL. A comparison of cemented and cementless titanium femoral components used for primary total hip arthroplasty: a radiographic and survivorship study. J Arthroplasty 2002; 17(5):584-91.
  • Ferris DM, Moodie GD, Dimond PM, Gioranni CW, Ehrlich MG, Valentini RF. RGD-coated titanium implants stimulate increased bone formation in vivo. Biomaterials 1999; 20(23-24):2323-31.
  • Guglielmotti MB, Renou S, Cabrini RL. A Histomorphometric Study of Tissue Interface by Laminar Implant Test in Rats. Int J Oral Maxillofac Implants 1999; 14(4):565-70.
  • Hooper GJ, Rothwell AG, Stringer M, Frampton C. Revision following cemented and uncemented primary total hip replacement: a seven-year analysis from the New Zealand Joint Registry. J Bone Joint Surg (Br) 2009; 91(4):451-8.
  • Lan J, Wang ZF, Shi B, Xia HB, Cheng XR. The influence of recombinant human BMP-2 on bone-implant osseointegration: biomechanical testing and histomorphometric analysis. Int J Oral Maxillofac Surg 2007; 36(4):345-9.
  • Lappalainen R, Santavirta SS. Potential of coatings in total hip replacement. Clin Orthop 2005; (430):72-9.
  • Lappalainen R, Selenius M. Joint bearing surfaces and replacement joint design. In: Joint replacement technology ( ed Revell, P. A). Woodhead Publishing Limited, Cambridge, UK 2008; 176-89.
  • Lappalainen R, Selenius M, Anttila A, Konttinen YT, Santavirta SS. Reduction of wear in total hip replacement prostheses by amorphous diamond coatings. J Biomed Mater Res 2003; 66B(1):410-3.
  • Miettinen SS, Jaatinen J, Pelttari A, Lappalainen R, Monkkonen J, Venesmaa PK, Kroger HP. Effect of locally administered zoledronic acid on injury-induced intramembranous bone regeneration and osseointegration of a titanium implant in rats. J Orthop Sci 2009; 14(4):431-6.
  • Moreland JR, Moreno MA. Cementless femoral revision arthroplasty of the hip: minimum 5 years followup. Clin Orthop 2001; (393):194-201.
  • Santavirta SS, Lappalainen R, Pekko P, Anttila A, Konttinen YT. The counterface, surface smoothness, tolerances, and coatings in total joint prostheses. Clin Orthop 1999; (369):92-102.
  • Santori FS, Ghera S, Moriconi A, Montemurro G. Results of the anatomic cementless prosthesis with different types of hydroxyapatite coating. Orthopedics 2001; 24(12):1147-50.
  • Schopper C, Moser D, Goriwoda W, Ziya-Ghazvini F, Spassova E, Lagogiannis G, Auterith A, Ewers R. The effect of three different calcium phosphate implant coatings on bone deposition and coating resorption: a long-term histological study in sheep. Clin Oral Implants Res 2005; 16(3):357-68.
  • Sorrells RB, Voorhorst PE, Murphy JA, Bauschka MP, Greenwald AS. Uncemented rotating-platform total knee replacement: a five to twelve-year follow-up study. J Bone Joint Surg (Am) 2004; 86(10):2156-62.
  • Toyras J, Korhonen RK, Voutilainen T, Jurvelin JS, Lappalainen R. Improvement of arthroscopic cartilage stiffness probe using amorphous diamond coating. J Biomed Mater Res B Appl Biomater 2005; 73(1):15-22.
  • Venesmaa P, Kroger H, Miettinen H, Jurvelin J, Suomalainen O, Alhava E. Bone loss around failed femoral implant measured by dual-energy X-ray absorptiometry. J Orthop Sci 2000; 5(4):380-4.
  • Venesmaa PK, Kroger HP, Miettinen HJ, Jurvelin JS, Suomalainen OT, Alhava EM. Monitoring of periprosthetic BMD after uncemented total hip arthroplasty with dual-energy X-ray absorptiometry–a 3-year follow-up study. J Bone Miner Res 2001; 16(6):1056-61.
  • Venesmaa PK, Kroger HP, Jurvelin JS, Miettinen HJ, Suomalainen OT, Alhava EM. Periprosthetic bone loss after cemented total hip arthroplasty: a prospective 5-year dual energy radiographic absorptiometry study of 15 patients. Acta Orthop Scand 2003; 74(1):31-6.
  • Xiao J, Zhou H, Zhao L, Sun Y, Guan S, Liu B, Kong L. The effect of hierarchical micro/nanosurface titanium implant on osseointegration in ovariectomized sheep. Osteoporos Int 2010; DOI 10.1007/s00198-010-1413-0.
  • Yamada H, Yoshihara Y, Henmi O, Morita M, Shiromoto Y, Kawano T, Kanaji A, Ando K, Nakagawa M, Kosaki N, Fukaya E. Cementless total hip replacement: past, present, and future. J Orthop Sci 2009; 14(2):228-41.
  • Yamaguchi K, Masuhara K, Ohzono K, Sugano N, Nishii T, Ochi T. Evaluation of periprosthetic bone-remodeling after cementless total hip arthroplasty. The influence of the extent of porous coating. J Bone Joint Surg (Am) 2000; 82(10):1426-31.