- Kärrholm J, Borssén B, Löwenhielm G, Snorrason F. Does early micromotion of femoral stem prostheses matter? 4-7-year stereoradiographic follow-up of 84 cemented prostheses. J Bone Joint Surg (Br) 1994; 76 (6): 912-7.
- Malchau H. On the importance of stepwise introduction of new hip implant technology. Thesis. Göteborg 1995. ISBN 91-628-1658-6.
- Mjöberg B. Loosening of the cemented hip prosthesis. The importance of heat injury. Acta Ortop Scand (Suppl 221) 1986; 57: 1-40.
- Mjöberg B. Fixation and loosening of hip prostheses. A review. Acta Orthop Scand 1991; 62 (5): 500-8.
- Mogensen B, Ekelund L, Hansson LI, Lidgren L, Selvik G. Surface replacement of the hip in chronic arthritis. A clinical, radiographic and roentgen stereophotogrammetric evaluation. Acta Orthop Scand 1982; 53 (6): 929-36.
- Nieuwenhuijse MJ, Valstar ER, Kaptein BL, Nelissen RG. The Exeter femoral stem continues to migrate during its first decade after implantation: 10-12 years of follow-up with radiostereometric analysis (RSA). Acta Orthop 2012; 83 (2): 129-34.
- Penny JO, Ding M, Varmarken JE, Ovesen O, Overgaard S. Early micromovement ofthe Articular Surface Replacement (ASR) femoral component: Two-year radiostereometry results. J Bone Joint Surg (Br) 2012; 94 (10): 1344-50.
- Pijls BG, Valstar ER, Nouta K-A, Plevier J WM, Fiocco M, Middeldorp S, Nelissen R GHH. Early migration of tibial components is associated with late revision. A systematic review and meta-analysis of 21,000 knee arthroplasties. Acta Orthop 2012a; 83 (6): x-y.
- Pijls BG, Nieuwenhuijse MJ, Fiocco M, Plevier J WM, Middeldorp S, Nelissen R GHH, Valstar ER. Early proximal migration of cups is associated with late revision in THA. A systematic review and meta-analysis of 26 RSA studies and 49 survival studies. Acta Orthop 2012b; 83 (6): x-y.
- Ryd L, Albrektsson BE, Carlsson L, Dansgård F, Herberts P, Lindstrand A, Regnér L, Toksvig-Larsen S. Roentgen stereophotogrammetric analysis as a predictor of mechanical loosening of knee prostheses. J Bone Joint Surg (Br) 1995; 77 (3): 377-83.
- Snorrason F, Kärrholm J. Primary migration of fully-threaded acetabular prostheses. A roentgen stereophotogrammetric analysis. J Bone Joint Surg (Br) 1990; 72 (4): 647-52.
- Thanner J, Freij-Larsson C, Kärrholm J, Malchau H, Wesslén B. Evaluation of Boneloc. Chemical and mechanical properties, and a randomized clinical study of 30 total hip arthroplasties. Acta Orthop Scand 1995; 66 (3): 207-14.
- Wolf O, Mattson P, Milbrink J, Larsson S, Mallmin H. Periprosthetic bone mineral density and fixation of the uncemented CLS stem related to different weight bearing regimens. A randomized study usinf DXA and RSA in 38 patients followed for 5 years. Acta Orthop 2010; 81 (3): 286-91.
- Wykman A, Selvik G, Goldie I. Subsidence of the femoral component in the noncemented hip. A roentgen stereophotogrammetric analysis. Acta Orthop Scand 1988; 59 (6): 635-7.
Acta Orthopaedica
Volume 83, 2012 - Issue 6
Open access
1,244
Views
52
CrossRef citations to date
0
Altmetric
Guest editorial
Radiostereometric analysis of early implant migration – a valuable tool to ensure proper introduction of new implants
Johan KärrholmDepartment of Orthopaedics, Institute of Surgical Sciences, Sahlgrenska University Hospital, Göteborg University,
Mölndal, Sweden;
The Swedish Hip Arthroplasty Register (www.shpr.se).Correspondence[email protected]
Pages 551-552
|
Published online: 05 Nov 2012
Related research
People also read lists articles that other readers of this article have read.
Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.
Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.