1,244
Views
52
CrossRef citations to date
0
Altmetric
Guest editorial

Radiostereometric analysis of early implant migration – a valuable tool to ensure proper introduction of new implants

Pages 551-552 | Published online: 05 Nov 2012

  • Kärrholm J, Borssén B, Löwenhielm G, Snorrason F. Does early micromotion of femoral stem prostheses matter? 4-7-year stereoradiographic follow-up of 84 cemented prostheses. J Bone Joint Surg (Br) 1994; 76 (6): 912-7.
  • Malchau H. On the importance of stepwise introduction of new hip implant technology. Thesis. Göteborg 1995. ISBN 91-628-1658-6.
  • Mjöberg B. Loosening of the cemented hip prosthesis. The importance of heat injury. Acta Ortop Scand (Suppl 221) 1986; 57: 1-40.
  • Mjöberg B. Fixation and loosening of hip prostheses. A review. Acta Orthop Scand 1991; 62 (5): 500-8.
  • Mogensen B, Ekelund L, Hansson LI, Lidgren L, Selvik G. Surface replacement of the hip in chronic arthritis. A clinical, radiographic and roentgen stereophotogrammetric evaluation. Acta Orthop Scand 1982; 53 (6): 929-36.
  • Nieuwenhuijse MJ, Valstar ER, Kaptein BL, Nelissen RG. The Exeter femoral stem continues to migrate during its first decade after implantation: 10-12 years of follow-up with radiostereometric analysis (RSA). Acta Orthop 2012; 83 (2): 129-34.
  • Penny JO, Ding M, Varmarken JE, Ovesen O, Overgaard S. Early micromovement ofthe Articular Surface Replacement (ASR) femoral component: Two-year radiostereometry results. J Bone Joint Surg (Br) 2012; 94 (10): 1344-50.
  • Pijls BG, Valstar ER, Nouta K-A, Plevier J WM, Fiocco M, Middeldorp S, Nelissen R GHH. Early migration of tibial components is associated with late revision. A systematic review and meta-analysis of 21,000 knee arthroplasties. Acta Orthop 2012a; 83 (6): x-y.
  • Pijls BG, Nieuwenhuijse MJ, Fiocco M, Plevier J WM, Middeldorp S, Nelissen R GHH, Valstar ER. Early proximal migration of cups is associated with late revision in THA. A systematic review and meta-analysis of 26 RSA studies and 49 survival studies. Acta Orthop 2012b; 83 (6): x-y.
  • Ryd L, Albrektsson BE, Carlsson L, Dansgård F, Herberts P, Lindstrand A, Regnér L, Toksvig-Larsen S. Roentgen stereophotogrammetric analysis as a predictor of mechanical loosening of knee prostheses. J Bone Joint Surg (Br) 1995; 77 (3): 377-83.
  • Snorrason F, Kärrholm J. Primary migration of fully-threaded acetabular prostheses. A roentgen stereophotogrammetric analysis. J Bone Joint Surg (Br) 1990; 72 (4): 647-52.
  • Thanner J, Freij-Larsson C, Kärrholm J, Malchau H, Wesslén B. Evaluation of Boneloc. Chemical and mechanical properties, and a randomized clinical study of 30 total hip arthroplasties. Acta Orthop Scand 1995; 66 (3): 207-14.
  • Wolf O, Mattson P, Milbrink J, Larsson S, Mallmin H. Periprosthetic bone mineral density and fixation of the uncemented CLS stem related to different weight bearing regimens. A randomized study usinf DXA and RSA in 38 patients followed for 5 years. Acta Orthop 2010; 81 (3): 286-91.
  • Wykman A, Selvik G, Goldie I. Subsidence of the femoral component in the noncemented hip. A roentgen stereophotogrammetric analysis. Acta Orthop Scand 1988; 59 (6): 635-7.