1,145
Views
13
CrossRef citations to date
0
Altmetric
Hip and knee

Wear of a sequentially annealed polyethylene acetabular liner

RSA measurements in 19 hips

, , &
Pages 470-473 | Received 10 Sep 2013, Accepted 09 Jun 2014, Published online: 20 Aug 2014

  • Bohm E, Petrak M, Gascoyne T, Turgeon T. The effect of adding tobramycin to Simplex P cement on femoral stem micromotion as measured by radiostereometric analysis: a 2-year randomized controlled trial. Acta Orthop 2012; 83 (2): 115-20.
  • Bradford L, Baker DA, Graham J, Chawan A, Ries MD, Pruitt LA. Wear and surface cracking in early retrieved highly cross-linked polyethylene acetabular liners. J Bone Joint Surg (Am) 2004; 86 (6): 1271-82.
  • Bragdon CR, Kwon YM, Geller JA, Greene ME, Freiberg AA, Harris WH, et al. Minimum 6-year followup of highly cross-linked polyethylene in THA. Clin Orthop 2007a; (465): 122-7.
  • Bragdon CR, Greene ME, Freiberg AA, Harris WH, Malchau H. Radiostereometric analysis comparison of wear of highly cross-linked polyethylene against 36- vs 28-mm femoral heads. J Arthroplasty (Suppl 2) 2007b; 22 (6:) 125-9.
  • Bryant D, Havey TC, Roberts R, Guyatt G. How many patients? How many limbs? Analysis of patients or limbs in the orthopaedic literature: a systematic review. J Bone Joint Surg (Am) 2006; 88 (1): 41-5.
  • Callary SA, Field JR, Campbell DG. Low wear of a second-generation highly crosslinked polyethylene liner: a 5-year radiostereometric analysis study. Clin Orthop 2013; (471) (11): 3596-600.
  • Calvert GT, Devane PA, Fielden J, Adams K, Horne JG. A double-blind, prospective, randomized controlled trial comparing highly cross-linked and conventional polyethylene in primary total hip arthroplasty. J Arthroplasty 2009; 24 (4): 505-10.
  • Currier BH, Currier JH, Mayor MB, Lyford KA, Collier JP, Van Citters DW. Evaluation of oxidation and fatigue damage of retrieved crossfire polyethylene acetabular cups. J Bone Joint Surg (Am) 2007; 89 (9): 2023-9.
  • D’Antonio JA, Capello WN, Ramakrishnan R. Second-generation annealed highly cross-linked polyethylene exhibits low wear. Clin Orthop 2012; (470) (6): 1696-704.
  • Derbyshire B, Prescott RJ, Porter ML. Notes on the use and interpretation of radiostereometric analysis. Acta Orthop 2009; 80 (1): 124-30.
  • Digas G, Karrholm J, Thanner J, Herberts P. 5-year experience of highly cross-linked polyethylene in cemented and uncemented sockets: two randomized studies using radiostereometric analysis. Acta Orthop 2007; 78 (6): 746-54.
  • Dumbleton JH, D’Antonio JA, Manley MT, Capello WN, Wang A. The basis for a second-generation highly cross-linked UHMWPE. Clin Orthop 2006; (453): 265-71.
  • . Furmanski J, Anderson M, Bal S, Greenwald AS, Halley D, Penenberg B, et al Clinical fracture of cross-linked UHMWPE acetabular liners. Biomaterials 2009; 30 (29): 5572-82.
  • Furmanski J, Kraay MJ, Rimnac CM. Crack initiation in retrieved cross-linked highly cross-linked ultrahigh-molecular-weight polyethylene acetabular liners: an investigation of 9 cases. J Arthroplasty 2011; 26 (5): 796-801.
  • Glyn-Jones S, Isaac S, Hauptfleisch J, McLardy-Smith P, Murray DW, Gill HS. Does highly cross-linked polyethylene wear less than conventional polyethylene in total hip arthroplasty? A double-blind, randomized, and controlled trial using roentgen stereophotogrammetric analysis. J Arthroplasty 2008a; 23 (3): 337-43.
  • Glyn-Jones S, McLardy-Smith P, Gill HS, Murray DW. The creep and wear of highly cross-linked polyethylene: a three-year randomised, controlled trial using radiostereometric analysis. J Bone Joint Surg (Br) 2008b; 90 (5): 556-61.
  • Kesteris U, Ilchmann T, Wingstrand H, Onnerfalt R. Polyethylene wear in Scanhip arthroplasty with a 22 or 32 mm head: 62 matched patients followed for 7-9 years. Acta Orthop Scand 1996; 67 (2): 125-7.
  • Lachiewicz PF, Heckman DS, Soileau ES, Mangla J, Martell JM. Femoral head size and wear of highly cross-linked polyethylene at 5 to 8 years. Clin Orthop 2009; (467) (12): 3290-6.
  • McCalden RW, MacDonald SJ, Rorabeck CH, Bourne RB, Chess DG, Charron KD. Wear rate of highly cross-linked polyethylene in total hip arthroplasty. A randomized controlled trial. J Bone Joint Surg (Am) 2009; 91 (4): 773-82.
  • Muratoglu OK, Bragdon CR, O’Connor D, Perinchief RS, Estok DM, 2nd, Jasty M, et al. Larger diameter femoral heads used in conjunction with a highly cross-linked ultra-high molecular weight polyethylene: a new concept. J Arthroplasty (Suppl 1) 2001; 16 (8): 24-30.
  • Rohrl SM, Li MG, Nilsson KG, Nivbrant B. Very low wear of non-remelted highly cross-linked polyethylene cups: an RSA study lasting up to 6 years. Acta Orthop 2007; 78 (6): 739-45.
  • Tarasevicius S, Robertsson O, Kesteris U, Kalesinskas RJ, Wingstrand H. Effect of femoral head size on polyethylene wear and synovitis after total hip arthroplasty: a sonographic and radiographic study of 39 patients. Acta Orthop 2008; 79 (4): 489-93.
  • Wang A, Manley M, Serekian P, Kurtz S, Gsell R, Martell J. Wear and structural fatigue simulation of crosslinked ultra-high molecular weight polyethylene hip and knee bearing applications—Crosslinked and thermally treated ultra-high molecular weight polyethylene for joint replacements, ASTM STP1445. ASTM International, West Conshohecken, PA, 2003: 151-68.