The innovation trap

(Co-editor)

  • Atwood S A, Patten E W, Bozic K J, Pruitt L A, Ries M D. Corrosion-induced fracture of a double-modular hip prosthesis: a case report. J Bone Joint Surg Am 2010; 92(6): 1522–5.
  • Bauer G C. What price progress? Failed innovations of the knee prosthesis. Acta Orthop Scand 1992; 63(3): 245–6.
  • Craig P, Bancroft G, Burton A, Collier S, Shaylor P, Sinha A. Raised levels of metal ions in the blood in patients who have undergone uncemented metal-on-polyethylene Trident-Accolade total hip replacement. Bone Joint J 2014; 96-b(1): 43–7.
  • Dangles C J, Altstetter C J. Failure of the modular neck in a total hip arthroplasty. J Arthroplasty 2010; 25(7): 1169.e5–7.
  • Davies B M, Branford White H A, Temple A. A series of four fractured Exeter stems in hip arthroplasty. Ann R Coll Surg Engl 2013; 95(8): e130–2.
  • Espehaug B, Furnes O, Engesaeter L B, Havelin L I. 18 years of results with cemented primary hip prostheses in the Norwegian Arthroplasty Register: concerns about some newer implants. Acta Orthop 2009; 80(4): 402–12.
  • Fokter S K, Rudolf R, Molicnik A. Titanium alloy femoral neck fracture—clinical and metallurgical analysis in 6 cases. Acta Orthop 2016; 87(2): 197–202.
  • Furnes O, Lie S A, Havelin L I, Vollset S E, Engesaeter L B. Exeter and charnley arthroplasties with Boneloc or high viscosity cement. Comparison of 1,127 arthroplasties followed for 5 years in the Norwegian Arthroplasty Register. Acta Orthop Scand 1997; 68(6): 515–20.
  • Kärrholm J. Radiostereometric analysis of early implant migration – a valuable tool to ensure proper introduction of new implants. Acta Orthop 2012; 83(6): 551–2.
  • Langton D J, Sidaginamale R, Lord JK, Nargol A V, Joyce T J. Taper junction failure in large-diameter metal-on-metal bearings. Bone Joint Res 2012; 1(4): 56–63.
  • Malchau H, Bragdon CR, Muratoglu OK. The stepwise introduction of innovation into orthopedic surgery: the next level of dilemmas. J Arthroplasty 2011; 26(6): 825–31.
  • Mathiesen E B, Lindgren J U, Blomgren G G, Reinholt F P. Corrosion of modular hip prostheses. J Bone Joint Surg Br 1991; 73(4): 569–75.
  • McGrory B J, MacKenzie J, Babikian G. A High prevalence of corrosion at the head-neck taper with contemporary Zimmer non-cemented femoral hip components. J Arthroplasty 2015; 30(7): 1265–8.
  • Morlock M M, Bünte D, Ettema H, Verheyen C C, Hamberg Å, Gilbert J. Primary hip replacement stem taper fracture due to corrosion in 3 patients. Acta Orthop 2016; 87(2): 189–192.
  • Panagiotidou A, Meswania J, Hua J, Muirhead-Allwood S, Hart A, Blunn G. Enhanced wear and corrosion in modular tapers in total hip replacement is associated with the contact area and surface topography. J Orthop Res 2013; 31(12): 2032–9.
  • Reito A, Eskelinen A, Pajamäki J, Puolakka T. Neck fracture of the Exeter stem in 3 patients: A cause for concern? Acta Orthop 2016; 87(2): 193–196.
  • Rokkum M, Bye K, Hetland K R, Reigstad A. Stem fracture with the Exeter prosthesis. 3 of 27 hips followed for 10 years. Acta Orthop Scand 1995; 66(5): 435–9.
  • Skendzel J G, Blaha J D, Urquhart A G. Total hip arthroplasty modular neck failure. J Arthroplasty 2011; 26(2): 338.e1–4.
  • Suominen S. Early failure with Boneloc bone cement: 4/8 femoral stems loose within 3 years. Acta Orthop Scand 1995; 66: 13.
  • Wilson D A, Dunbar M J, Amirault J D, Farhat Z. Early failure of a modular femoral neck total hip arthroplasty component: a case report. J Bone Joint Surg Am 2010; 92(6): 1514–7.
  • Witt F, Bosker B H, Bishop N E, Ettema H B, Verheyen C C, Morlock M M. The relation between titanium taper corrosion and cobalt-chromium bearing wear in large-head metal-on-metal total hip prostheses: a retrieval study. J Bone Joint Surg Am 2014; 96(18): e157.
  • Wright G, Sporer S, Urban R, Jacobs J. Fracture of a modular femoral neck after total hip arthroplasty: a case report. J Bone Joint Surg Am 2010; 92(6): 1518–21.