References
- Black J. Does corrosion matter?. J Bone Joint Surg (Br) 1988; 70(4)517–20
- Böstman O M. Absorbable implants for the fixation of fractures. J Bone Joint Surg (Am) 1991; 73(1)148–53
- Böstman O, Vainionpää S, Hirvensalo E, Mäkelä A, Vihtonen K, Törmälä P, Rokkanen P. Biodegradable internal fixation for malleolar fractures. A prospective randomised trial. J Bone Joint Surg (Br) 1987; 69(4)615–9
- Böstman O, Hirvensalo E, Vainionpää S, Mäkelä A, Vihtonen K, Törmälä P, Rokkanen P. Ankle fractures treated using biodegradable internal fixation. Clin Orthop 1989; 238: 195–203
- Böstman O, Hirvensalo E, Mäkinen J, Rokkanen P. Foreign body reactions to fracture fixation implants of biodegradable synthetic polymers. J Bone Joint Surg (Br) 1990; 72(4)592–6
- Gammelgaard N, Jensen J. Wound complications after closure of abdominal incisions with Dexon or Vicryl. A randomized double blind study. Acta Chir Scand 1983; 149(5)505–8
- Hirvensalo E. Fracture fixation with biodegradable rods. Forty–one cases of severe ankle fractures. Acta Orthop Scand 1989; 60(5)601–6
- Hirvensalo E, Bostman O, Törmälä P, Vainionpää S, Rokkanen P. Chevron osteotomy fixed with absorbable polyglycolide pins. Foot Ankle 1991; 11(4)212–8
- Hoffmann R, Krettek C, Haas N, Tscherne H. Die distale Radiusfraktur. Frakturstabilisierung mit biodegradablen Osteosynthese–Stiften. Experimentelle Untersuchungen und erste klinische Erfahrungen. Unfallchirurg 1989; 92(9)430–4
- Lange D A., Zaret P, Merlotti G J., Robin A P., Sheaff C, Barrett I A. The use of absorbable mesh in splenic trauma. J Trauma 1988; 28(3)269–75
- Lindsjö U. Operative treatment of ankle fracture dislocations. A follow–up study of 306/321 consecutive cases. Clin Orthop 1985; 199: 28–38
- Mak K H., Chan K M., Leung P C. Ankle fracture treated with the AO principle an experience with 116 cases. Injury 1985; 16(4)265–72
- O'Sullivan M E., Chao E Y., Kelly P J. The effects of fixation on fracture healing. J Bone Joint Surg (Am) 1989; 71(2)306–10
- Partio E K., Böstman O, Hirvensalo E, Pätiälä H, Vainionpää S, Vihtonen K, Törmälä P, Rokkanen P. The indication for the fixation of fractures with totally absorbable SR–PGA screws. Acta Orthop Scand (Suppl 237) 1990; 61: 43–4
- Poigenfürst J, Leixnering M, Ben Mokhtar M. Lokalkomplik–ationen nach Implantation von Biorod. Aktuel Traumatol 1990; 20(3)157–9
- Rogers F B., Baumgartner N E., Robin A P., Barrett J A. Absorbable mesh splenorrhaphy for severe splenic injuries: functional studies in an animal model and an additional patient series. J Trauma 1991; 31(2)200–4
- Rokkanen P. Absorbable implants in the fixation of fractures. Ann Chir Gynaecol 1990; 79(3)117–22
- Rokkanen P, Böstman O, Vainionpää S, Vihtonen K, Törmälä P, Laiho J, Kilpikari J, Tanmiinmäki M. Biodegradable implants in fracture fixation: Early results of treatment of fractures of the ankle. Lancet 1985; 1(8443)1422–4
- Rostoker G, Robin J, Binet O, Blamoutier J, Paupe J, Lessana Leibowitch M, Bedouelle J, Sonneck J M., Garrel J B., Millet P. Dermatitis due to orthopaedic implants. A review of the literature and report of three cases. J Bone Joint Surg (Am) 1987; 69(9)1408–12
- Ruf W, Schult W, Buhl K. Die Stabilisierung von Malleolarfrakturen und Flakeverletzungen mit resorbierbaren Polyglykolid Stiffen (Biofix). Unfallchirurgie 1990; 16(4)202–9
- Santavirta S, Konttinen Y T., Saito T, Grönblad M, Partio E, Kemppinen P, Rokkanen P. Immune response to polyglycolic acid implants. J Bone Joint Surg (Br) 1990; 72(4)597–600
- Steinmann R, Gemgross H, Hartel W. Die Verwendung bioresorbierbarer Implantate (Biofix) in der Chirurgie. Indikation, Technik, erste klinische Ergebnisse. Aktuel Traumatol 1990; 20(2)102–7