628
Views
61
CrossRef citations to date
0
Altmetric
Original Article

Exeter and Charnley arthroplasties with Boneloc or high viscosity cement: Comparison of 1, 127 arthroplasties followed for 5 years in the Norwegian Arthroplasty Register

, , , &
Pages 515-520 | Received 04 May 1997, Accepted 11 Sep 1997, Published online: 08 Jul 2009

References

  • Ahnfelt L, Herberts P, Malchau H. Prognosis of total hip replacement. A Swedish multicenter study of 4, 664 revisions. Acta Orthop Scand (Suppl 238) 1990; 61: 1–26
  • Airman D G. Analysis of survival times. Practical Statistics for Medical Research. Chapman and Hall, London 1991; 365–95
  • Charnley J. Acrylic Cement in Orthopaedic Surgery. Churchill Livingstone, Edinburgh and London 1972
  • Dogan A, Bek B, Cevik N N, Usanmaz A. The effect of preparation conditions of acrylic denture base materials on the level of residual monomer, mechanical properties and water absorption. J Dent 1995; 23: 313–8
  • Engesaeter L B, Fumes A, Havelin L I, Lie S A, Vollset S E. Hofteregisteret. God samfunnsøkonomi. Tidsskr Nor Lsegeforen 1996; 116: 3025–7
  • Espehaug B, Havelin L I, Engesaeter L B, Vollset S E, Lange-Land NL. Early revision among 12, 179 hip prostheses. A comparison of 10 different brands reported to the Norwegian Arthroplasty Register, 1987–1993. Acta Orthop Scand 1995; 66: 487–93
  • Fowler J L, Gie G A, Lee A JC, Ling R SM. Experience with the Exeter Total Hip Replacement since 1970. Orthop Clin North Am 1988; 19: 477–89
  • Furnes A, Lie S A, Havelin L I, Engesaeter L B, Vollset S E. The economic impact of failures in total hip replacement surgery. Acta Orthop Scand 1996; 67: 115–21
  • Haas S S, Brauer G M, Dickson G. A characterization of polymethylmethacrylate bone cement. J Bone Joint Surg (Am) 1975; 57: 380–91
  • Havelin L I, Espehaug B, Vollset S E, Engesaeter L B, Lange-Land N. The Norwegian Arthroplasty Register. A survey of 17, 444 hip replacements 1987–1990. Acta Orthop Scand 1993; 64: 245–51
  • Havelin L I, Espehaug B, Vollset S E, Engesaeter L B. The effect of the type of cement on early revision of Charnley total hip prostheses. J Bone Joint Surg (Am) 1995; 77: 1543–50
  • Havelin L I, Furnes O, Lie S A. Annual report, Norwegian Arthroplasty Register. Department of Orthopaedics, Haukeland University Hospital, Bergen, Norway 1996
  • Jensen J S, Trap B, Skydsgaard K. Delayed contact hypersensitivity and surgical glove penetration with acrylic bone cements. Acta Orthop Scand 1991; 62: 24–8
  • Jensen J S, Bødtker S, Kramhøft M, Thomsen P B, Petersen D, Nielsen K. Clinical results after 2–4 years with a new MMA/DMA/IBMA bone cement used for fixation of the femoral stem. Hip Int 1995; 5: 31–6
  • Kindt-Larsen T, Smith D B, Jensen J S. Innovations in acrylic bone cement and application equipment. J Appl Biomat 1995; 6: 75–83
  • Klyver H, Jacobsen K, Kofoed H. Boneloc versus Simplex cement for fixation of femoral components. An interim report of a prospective randomized study of THRs with a 2.5-year mean follow-up time. Hip Int 1996; 6: 112–8
  • Linder L. Editorial. Boneloc–the Christiansen experience revisited. Acta Orthop Scand 1995; 66: 205–6
  • Malchau H. On the importance of stepwise introduction of new hip implant technology. Assessment of total hip replacement using clinical evaluation, radiostereometry, digitised radiography and a national hip registry. Thesis, GothenburgSweden 1995
  • Mjöberg B. Loosening of the cemented hip prosthesis. The importance of heat injury. Acta Orthop Scand (Suppl 221) 1986; 57: 1–40
  • Murray D W, Carr A J, Bulstrode C J. Which primary total hip replacement?. J Bone Joint Surg (Br) 1995; 77: 520–7
  • Nilsen A R, Wiig M. Total hip arthroplasty with Boneloc. Acta Orthop Scand 1996; 67: 57–9
  • Nilsson K G, Kärrholm J. RSA in the assessment of aseptic loosening. J Bone Joint Surg (Br) 1996; 78: 1–3
  • Nimb L, Stump J, Jensen J S. Improved cortical histology after cementation with a new MMA-DMA-IBMA bone cement: An animal study. J Biomed Mater Res 1993; 27: 565–74
  • Riegels-Nielsen P, Sørensen L, Andersen H M, Lindequist S. Boneloc cemented total hip prostheses. Acta Orthop Scand 1995; 66: 215–7
  • Schemper M, Smith T L. A note on quantifying follow-up in studies of failure time. Controlled Clin Trials 1996; 17: 343–6
  • Seymor and Carraher: Polymer Chemistry. Marcel Dekker Inc, New York and Basel 1981
  • Sudmann E, Havelin L I, Lunde O D, Rait M. The Charnley versus the Christiansen total hip arthroplasty. Acta Orthop Scand 1983; 54: 545–52
  • Thanner J, Freij-Larsson C, Karrholm J, Malchau H, Wesslen B. Evaluation of Boneloc. Acta Orthop Scand 1995; 66: 207–14

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.