- Burkart W, Schmotz K. Grinding and polishing: Theory and practice. Porcullis Press, Redhill 1981
- Cordero J, Munuera L, Folgueira M D. Influence of metal implants on infection. An experimental study in rabbits. J Bone Joint Surg (Br) 1994; 76(5)717–20
- Davidson J A, Kovacs P. Evaluation of metal ion release during articulation of metal and ceramic femoral heads. Proceedings of the Eighth Southern Biomedical Engineering Conference. Richmond, Virginia 1989; 33–7
- Dowson D, Jobbins B, Seyed‐Harraf A. An evaluation of the penetration of ceramic femoral heads into polyethylene acetabular cups. Wear 1993; 162: 880–9, 164 (1–2)
- Gillespie W J, Henry D A, O'Cormel D L, Kendrick S, Juszczak E, McLnneny K, Derby L. Development of hematopoietic cancers after implantation of total joint replacement. Clin Or‐thop 1996; 329S: S290–6
- Goodman S, Aspenberg P, Song Y, Knoblich G, Huie P, Regula D, Lidgren L. Tissue ingrowth and differentiation in the bone‐harvest chamber in the presence of cobalt‐chromium‐alloy and high‐density‐polyethylene particles. J Bone Joint Surg (Am) 1995; 77(7)1025–35
- Haynes D R, Rogers S D, Hay S, Pearcy M J, Howie D W. The differences in toxicity and release of bone‐resorbing mediators induced by titanium and cobalt‐chromium‐ailoy wear particles. J Bone Joint Surg (Am) 1993; 75(6)825–34
- Howie D W. Tissue response in relation to type of wear particles around failed hip arthroplasties. J Arthroplasty 1990; 5(4)337–48
- Kothari M, Barrel D L, Booker J F. Surface geometry of retrieved McKee‐Farrar total hip replacements. Clin Orthop 1996; 329S: S141–7
- Kreibich D N, Moran C G, Delves H T, Owen T D, Pinder I M. Systemic release of cobalt and chromium after uncemented total hip replacement. J Bone Joint Surg (Br) 1996; 78(1)18–21
- Lewis C G, Sunderman F W. Metal carcinogenesis in total joint arthroplasty. Animal models. Clin Orthop 1996; 329S: S264–8
- Maloney W J, Smith R L, Castro F, Schurman D J. Fibroblast response to metallic debris in vitro. Enzyme induction, cell proliferation, and toxicity. J Bone Joint Surg (Am) 1993; 75(6)835–44
- Margevicius K J, Bauer T W, McMahon J T, Brown S A, Merritt K. Isolation and characterization of debris in membranes around total joint prostheses. J Bone Joint Surg (Am) 1994; 76(11)1664–75
- McKellop H, Park S ‐H, Chiesa R, Doom P, Lu B, Normand P, Grigoris P, Amstutz H. In vivo wear of 3 types of metal on metal hip prostheses during 2 decades of use. Clin Orthop 1996; 329S: S128–40
- Medley J B, Chan F W, Krygier J J, Bobyn J D. Comparison of alloys and designs in a hip simulator study of metal on metal implants. Clin Orthop 1996; 329S: S148–59
- Meldrum R D, Bloebaum R D, Dorr L D. Metal ion concentrations in retrieved polyethylene total hip inserts and implications for artifactually high readings in tissue. J Biomed Mater Res 1993; 27(11)1349–55
- Pazzaglia U E, Dell'Orbo C, Wilkinson M J. The foreign body reaction in total hip arthroplasties: A correlated light‐microscopy, SEM, and TEM study. Arch Orthop Trauma Surg 1987; 106(4)209–19
- Rae T. A study on the effects of particulate metals of orthopaedic interest on murine macrophages in vitro. J Bone Joint Surg (Br) 1975; 57(4)444–50
- Rae T. Comparative laboratory studies on the production of soluble and particulate metal by total joint prostheses. Arch Orthop Trauma Surg 1979; 95(1/2)71–9
- Saikko V, Paavolainen P, Kleimola M, Slatis P. A five‐station hip joint simulator for wear rate studies. J Eng Med 1992; 206(H4)195–200
- Schmidt M, Weber H, Schon R. Cobalt chromium molybdenum metal combination for modular hip prostheses. Clin Orthop 1996; 329S: S35–47
- Semlitsch M, Willert H G. Clinical wear behaviour of ultra‐high molecular weight polyethylene cups paired with metal and ceramic ball heads in comparison to metal‐on‐metal pairings of hip joint replacements. J Eng Med 1997; 211(HI)73–88
- Shahgaldi B F, Heatley F W, Dewar A, Corrin B. In vivo corrosion of cobalt‐chromium and titanium wear particles. J Bone Joint Surg (Br) 1995; 77(6)962–6
- Steinemann S G. Corrosion of surgical implants. In vivo and in vitro tests. Evaluation of biomaterials, G D Winter, J L Leray, K de Groot. John Wiley & Sons Ltd., Chichester 1980; 1, 34
- Streicher R M, Semlitsch M, Schon R, Weber H, Rieker C. Metal‐on‐metal articulation for artificial hip joints: laboratory study and clinical results. J Eng Med 1996; 210(H3)223–32
- Walker P S, Gold B L. The tribology (friction, lubrication and wear) of all‐metal artificial hip joints. Wear 1971; 17(4)285–99
- Weber B G. Experience with the Metasul total hip bearing system. Clin Orthop 1996; 329S: S69–77