References
- Ulrich-Vinther M, Puggaard H, Lange B. Prospective 1-year follow-up study comparing joint prosthesis with tendon interposition arthroplasty in treatment of trapeziometacarpal osteoarthritis. J Hand Surg 2008;33A:1369–77.
- Alnot JY, Saint Laurent Y. Total trapeziometacarpal arthroplasty. Report of seventeen cases of degenerative arthritis of the trapeziometacarpal joint. Ann Chir Main 1985;4:11–21.
- Hansen TB, Snerum L. Elektra trapeziometacarpal prosthesis for treatment of osteoarthrosis of the basal joint of the thumb. Scand J Plast Reconstr Surg Hand Surg 2008;42:316–19.
- Hansen TB, Vainorius D. High loosening rate of the Moje Acamo prosthesis for treating osteoarthritis of the trapeziometacarpal joint. J Hand Surg Eur Vol 2008;33:571–4.
- Perez-Ubeda MJ, Garcia-Lopez A, Martinez FM, Vilanova EJ, Martos MM, Lopez-Duran L. Results of the cemented SR trapeziometacarpal prosthesis in the treatment of thumb carpometacarpal osteoarthritis. J Hand Surg 2003;28A:917–25.
- van Cappelle HG, Elzenga P, van Horn JR. Long-term result and loosening analysis of de la Caffinière replacement of the trapeziometacarpal joint. J Hand Surg 1999;24A:476–82.
- Wachtl SW, Guggenheim PR, Sennwald GR. Cemented and non-cemented replacement of the trapeziometacarpal joint. J Bone Joint Surg 1998;80B:121–5.
- Pearce AI, Richards RG, Milz S, Schneider E, Pearce SG. Animal models for implant biomaterial research in bone: a review. Eur Cell Mater 2007;13:1–10.
- Hansen TB, Larsen K, Bjergelund L, Stilling M. Trapeziometacarpal joint implants can be evaluated by roentgen stereophotogrammetric analysis. J Hand Surg Eur Vol 2010;35:480–5.
- Pendse A, Nisar A, Shah SZ, Bhosale A, Freeman JV, Chakrabarti I. Surface replacement trapeziometacarpal joint arthroplasty – early results. J Hand Surg Eur Vol 2009;34:748–57.
- Imeada T, Cooney WP, Niebur GL, Linscheid R, An KN. Kinematics of the trapeziometacarpal joint: a biomechanical analysis comparing tendon interposition arthroplasty and total-joint arthroplasty. J Hand Surg 1996;21A:544–53.
- Uchiyama S, Cooney WP, Niebur G, An KN, Linscheid RL. Biomechanical analysis of the trapeziometacarpal joint after surface replacement arthroplasty. J Hand Surg 1999;24A:483–90.
- Naidu SH, Kulkarni N, Saunders M. Titanium basal joint arthroplasty: a finite element analysis and clinical study. J Hand Surg 2006;31A:760–5.
- Klanke J, Partenheimer A, Westermann K. Biomechanical qualities of threaded acetabular cups. Int Orthop 2002;26:278–82.
- Effenberger H, Witzel U, Lintner F, Rieger W. Stress analysis of threaded cups. Int Orthop 2001;25:228–35.
- Witzel U, Rieger W, Effenberger H. Three-dimensional stress analysis of threaded cups – a finite element analysis. Int Orthop 2008;32:195–201.
- Scheerlinck T, Delport H, Kiewitt T. Influence of the cementing technique on the cement mantle in hip resurfacing: an in vitro computed tomography scan-based analysis. J Bone Joint Surg 2010;92A:375–87.
- Daecke W, Veyel K, Wieloch P, Jung M, Lorenz H, Martini A. Osseointegration and mechanical stability of pyrocarbon and titanium hand implants in a load bearing in vivo model for small joint arthroplasty. J Hand Surg 2006;31A:90–7.