References
- AAP (American Academy of Pediatrics). 1985. Pediatric Nutrition Handbook, 2nd ed. In: Forbes GB, Woodruff CW, Eds, Committee on Nutrition. Academy of Pediatrics: Elk Grove Village, IL.
- Arduini F, Di Giorgio F, Amine A, Cataldo F, Moscone D, Palleschi G. 2010. Electroanalytical characterization of carbon black nanomaterial paste electrode: development of highly sensitive tyrosinase biosensor for catechol detection. Anal Lett. 43:1688–1702.
- Arslan F, Ustabas S, Arslan H. 2011. An amperometric biosensor for glucose determination prepared from glucose oxidase immobilized in polyaniline-polyvinylsulfonate film. Sensors. 11:8152–8153.
- Arslan H, Özdemir M, Zengin H, Zengin G. 2012. Glucose biosensing at carbon paste electrodes containing polyaniline-silicondioxide composite. Int J Electrochem Sci. 7:10205–10214.
- Carter N, Trenerry VC. 1996. The determination of choline in vitamin preparations, infantformula and selected foods by capillaryzone electrophoresis within direct ultraviolet detection. Electrophoresis. 17:1622–1626.
- Chen C, Jiang Y, Kan J. 2006. Anon interference polypyrrole glucose biosensor. Biosens Bioelectron. 22:639–643.
- Gülce H, Aktas YS, Gülce A, Yıldız A. 2003. Polyvinyl ferrocenium immobilized enzyme electrode for choline analysis. Enzyme Microb Technol. 32:895–899.
- Ikarashi Y, Maruyama Y. 1993. Liquid chromatography with electrochemical detection for quantitation of bound choline liberated by phospholipase D hydrolysis from phospholipids containing choline in rat plasma. J Chromatogr. 616:323–326.
- Langer JJ, Filipiak M, Kecin´ska J, Jasnowska J, Włodarczak J, Buładowski B. 2004. Polyaniline biosensor for choline determination. Surface Sci. 573:140–145.
- Lied E, Braekkan OR. 1975. Determination of total choline in biologicalmaterials. Int J Vitamin Nutr Res. 45:438–447.
- Luque L, Rodrıguez MC, Rivas GA. 2005. Glucose biosensors based on the immobilization of copperoxide and glucose oxidase with in a carbon paste matrix. Talanta. 66:467–471.
- Martinez SEV. 1983. Simultaneous determination of choline and betaine in some fish materials. Analyst. 108:1114–1119.
- Michel V, Yuan Z, Ramsubir S, Bakovic M. 2006. Choline transport for phospholipid synthesis. Exp Biol Med. 231:490–504.
- Özdemir M, Arslan F, Arslan H. 2012. An amperometric biosensor for choline determination prepared from choline oxidase immobilized in polypyrrole-polyvinyl-sulfonate film. Artif Cells Blood Substit Biotechnol. 40:280–284.
- Patia S, Quinto M, Palmisano F. 2007. Flow injection determination of choline in milk hydrolysates by an immobilized enzyme reactor coupled to a selective hydrogen peroxide amperometric sensor. Analytica Chimica Acta. 594:234–239.
- Razola SS, Pochet S, Grosfils K, Kauffmann JM. 2003. Amperometric determination of choline released from rat submandibularglandacinar cells using a choline oxidase biosensor. Biosens Bioelectron. 18:185–191.
- Saucerman JR, Winstead CE, Jones TM. 1984. Quantitative gas chromatographic headspace determination of choline in adultand infant formula products. J Assoc Anal Chem. 67:982–985.
- Shi H, Yang Y, Huang J, Zhao Z, Xu X, Anzai J-I, et al. 2006. Amperometric choline biosensors prepared by layer-by-layer deposition of choline oxidase on the Prussian blue-modified platinum electrode. Talanta. 70:852–858.
- Shi Q, Wang P, Jiang Y, Kan J. 2009. Glucose biosensor based on polyaniline synthesized in ionic liquid Biocatal. Biotransfor. 27:54–59.
- Zeisel SH. 1987. Diet and brainfunction: available information and misinformation. In: Grand RJ, Sutphen JL, Dietz WH, Eds. Pediatric Nutrition: Theory and Practice. Boston, MA: Butterworths, pp. 801–808.
- Zeisel SH. 2000. Choline: an essential nutrient for humans. Nutrition. 16:669–671.
- Zeisel SH. 2004. Nutritional importance of choline for brain development. J Am Coll Nutr23:621S–626S.
- Zengin H, Erkan B. 2010. Synthesis and characterization of polyaniline/ silicon dioxide composites and preparation of conductive films. Polym Adv Technol. 21:216–223.
- Zhang Z, Wang J, Wang X, Wang Y, Yang X. 2010. A sensitive choline biosensor with supramolecular architecture. Talanta. 82:483–487.