References
- Akyilmaz E, Erdogan A, Öztürk R, Yaşa I. 2007. Sensitive determination of L-lysine with a new amperometric microbial biosensor based on Saccharomyces cerevisiae yeast cells. Biosens Bioelectron. 22:1055.
- Carpenter KJ, Booth VH. 1973. Damage to lysine in food processing: its measurement and its significance. Nutr Abstr Rev. 43:423.
- Chen RLC, Lee MH, Matsumoto K. 1996. Selective biosensing of L-lysine by a low-temperature flow-injection technique using an immobilized lysine oxidase reactor. Anal Sci. 12:87.
- Fernández-Trapiella AC. 1990. Quantitative analysis methionine, cysteine and lysine in feeds by reverse-phase liquid chromatography using precolumn derivatization with 9-fluorenylmethyl chloroformate: preliminary study. J Assoc Off Anal Chem. 73:935.
- Dempsey E, Wang J, Wollenberger U, Ozsoz MR, Smyth MR. 1992. A lysine dehydrogenase-based electrode for biosensing of L-lysine. Biosens Bioelectron. 7:323.
- Guerrieri A, Cataldi TRI, Ciriello R. 2007. The kinetic and analytical behaviours of an l-lysine amperometric biosensor based on lysine oxidase immobilised onto a platinum electrode by co-crosslinking. Sens Actuators B Chem. 126:424.
- Jones BN, Gilligan JP. 1983. O-Phthaldialdehyde precolumn derivatization and reversed-phase high-performance liquid chromatography of polypeptide hydrolysates and physiological fluids. J Chromatogr. 266:471.
- Karakuş E, Pekyardımcı Ş , ve Kılıç E. 2005. Urea biosensors based on PVC membrane containing palmitic acid. Artificial Cells Blood Substitutes and Biotechnology. 33:329–341.
- Kelly SC, O’Connel PJ, O’Sullivan CK, Guilbault GG. 2000. Development of an interferent free amperometric biosensor for determination of L-lysine in food. Anal Chim Acta. 412:111.
- Lavagnini MG, Moscone D, Palleschi G, Compagnone D, Cremisini C. 1993. Amperometric lysine bioprobes analysis in feeds. Talanta. 40:1301.
- Li H, He H, Wolfbeis OS. 1992. An optical biosensor for lysine based on the use of lysine decarboxylase and a cadaverine-sensitive membrane. Biosens Bioelectron. 7:725.
- Marconi E, Panfili G, Messia MC, Cubadda R, Comaagnone D, Palleschi G. 1996. Fast analysis of lysine in food using protein microwave hydrolysis and electrochemical biosensor. Anal Lett. 29:1125.
- Romette JL, Yang JS, Kusakabe H. 1983. Enzyme electrode for specific determination of L-lysine. Biotechnol Bioeng. 25:2557.
- Saurina J, Hernández-Cassou S, Fabregas E, Alegret S. 1998. Potentiomet-ric biosensor for lysine analysis based on a chemically immobilizedlysine oxidase membrane. Anal Chim Acta. 371:49.
- Siegler K, Weber B, Weber E, Tonder K, Klingner E, Riechert F. 1994. A lysine sensor for process control. J Chem Technol Biotechnol. 59:279.
- Simonian AL, Badalian IE, Berezov TT, Smirnova IP, Khaduev SH. 1994. Flow-injection amperometric biosensor on immobilized L-lysine oxidase for L-lysine determination. Anal Lett. 27:2849.
- Thio NP, Tompkins DH. 1989. Regulatory approach to determination of lysine in feedstuffs by liquid chromatography with fluorescence detection via pre-column dansylation. J Assoc Off Anal Chem. 72:69.
- Vrbová E, Marek M, Ralys E. 1992. Biosensor for the determination of L-lysine. Anal Chimica Acta. 270:131.
- White WC, Guilbault GC. 1978. Lysine specific enzyme electrode for determination of lysine in grains and foodstuffs. Anal Chem. 50:1481.