1,019
Views
6
CrossRef citations to date
0
Altmetric
Technical Paper

Determination of Ozone in Outdoor and Indoor Environments Using Nitrite-Impregnated Passive Samplers Followed by Ion Chromatography

, , , &
Pages 974-980 | Published online: 29 Feb 2012

References

  • Lippmann, M. Health Effects of Ozone, a Critical Review; J. Air Pollut. Control Assoc. 1989, 39, 672–695.
  • McDonnell, W.F.; Chapman, R.S.; Leigh, M.W.; Strope, G.L.; Collier, A.M. Respiratory Responses of Vigorously Exercising Children to 0.12 ppm Ozone Exposure; Am. Rev. Respir. Dis. 1985, 132, 875–879.
  • Spektor, D.M.; Lippmann, M.; Lioy, P.J.; Thurston, G.D.; Citak, K.; James, D.J.; Bock, N.; Speizer, F.E.; Hayes, C. Effects of Ambient Ozone on Respiratory Function in Active Normal Children; Am. Rev. Respir. Dis. 1988, 137, 313–320.
  • McConnell, R.; Berhane, K.; Gilliland, F.; London, S.J.; Vora, H.; Avol E.; Gauderman, W.J.; Margolis, H.G.; Lurmann, F.; Thomas, D.C.; Peters, J.M. Air Pollution and Bronchitic Symptoms in Southern California Children with Asthma; Environ. Health Perspect. 1999, 107, 757–760.
  • Levy, J.I.; Carrothers, T.J.; Tuomisto, J.T.; Hammitt, J.K.; Evans, J.S. Assessing the Public Health Benefits of Reduced Ozone Concentrations; Environ. Health Perspect. 2001, 109, 1215–1226.
  • Weschler, C.J. Ozone in Indoor Environments: Concentrations and Chemistry; Indoor Air 2000, 10, 269–288.
  • Weschler, C.J. Ozone’s Impact on Public Health: Contributions from Indoor Exposures to Ozone and Products of Ozone Initiated Chemistry; Environ. Health Perspect . 2006, 114, 1489–1496.
  • Lee, K.; Xue, J.; Geyh, A.S.; Ozkaynak, A.H.; Leaderer, B.P.; Weschler, C.J.; Spengler, J.D. Nitrous Acid, Nitrogen Dioxide and Ozone Concentrations in Residential Environments; Environ. Health Perspect. 2002, 110, 145–150.
  • Finkelstein, J.N.; Johnston, C.J. Enhanced Sensitivity of the Postnatal Lung to Environmental Insults and Oxidant Stress; Pediatrics 2004, 113, 1092–1096.
  • Delfino, R.J.; Gong, H., Jr.; Linn, W.S.; Pellizzari, E.D.; Hu, Y. Asthma Symptoms in Hispanic Children and Daily Ambient Exposures to Toxic and Criteria Air Pollutants; Environ. Health Perspect. 2003, 111, 647–656.
  • Goh, D.Y.; Chew, F.T.; Quek, S.C.; Lee, B.W. Prevalence and Severity of Asthma, Rhinitis, and Eczema in Singapore Schoolchildren; Arch. Dis. Child. 1996, 74, 131–135.
  • Chew, F.T.; Teo, J.; Quak, S.H.; Lee, B.W. Factors Associated with Increased Respiratory Symptoms among Asthmatic Children in Singapore; Asian Pac. J. Allergy Immunol. 1999, 17, 143–153.
  • Wilkins, C.K.; Wolkoff, P.; Clausen, P.A.; Hammer, M.; Nielsen, G. D. Upper Airway Irritation of Terpene/Ozone Oxidation Products (TOPS) dependence on Reaction Time, Relative Humidity and Initial Ozone Concentration; Toxicol. Lett. 2003, 143, 109–114.
  • Occupational Safety and Health Administration. Salt Lake Technical Carter: Ozone (IGFF) in Workplace Atmospheres (USDOL/OSHA-SLCAL Method No. ID-214); Occupational Safety and Health Administration: Washington, DC, 1995.
  • Lee, K.; Parkhurst, W.J.; Xue, J.; Ozkaynak, A.H.; Neuberg, D.; Spengler, J.D. Outdoor/Indoor/Personal Exposures of Children in Nashville, Tenneesse; J. Air & Waste Manage. Assoc. 2004, 54, 352–359.
  • Copper, C.L.; Callahan, J.H. Capillary Electrophoresis as a Method for Ozone Determination in Atmosphere; Talanta 2002, 58, 823–/830.
  • Koutrakis, P.; Wolfson, J.M;. Bunyaviroch, A.; Froehlich, S. .; Hirano, K.; Muliki, J.D. Measurement of Ambient Ozone Using Nitrite Coated Filter; Anal. Chem. 1993, 65, 209–214.
  • Helaleh, M.I.H., Ngudiwaluyo, S.; Korenaga, T.; Tanaka, K. Development of Passive Sampler Technique for Ozone Monitoring: Estimation of Indoor and Outdoor Concentration; Talanta 2002, 58, 649–659.
  • Zhou, J.; Smith, S. Measurement of Ozone Concentration in Ambient Air Using a Badge-Type Passive Monitor; J. Air & Waste Manage. Assoc. 1997, 47, 697–703.
  • Liu, Y.; Kaiser, E.; Avdalovic, N. Determination of Trace Level of Anions in High Purity Water Samples by Ion Chromatography with an Automated Online Eluent Generation System; Microchem. J. 1999, 62, 164–173.
  • Liu, Y.; Avdalovic, N.; Pohl, C.; Matt, R.; Dhillon, H.; Kiser, R. An Online High Purity Acid and Base Eluent Generation for Ion Chromatography; Am. Lab. 1998, 30, 48C.
  • Lu, Z.; Liu, Y.; Barreto, V.; Pohl, C.; Avdalovic, N.; Joyce, R.; Newton, B. Determination of Anions at Trace Levels in Power Plant Water Samples by Ion Chromatography with Electrolytic Eluent Generation and Suppression System; J. Chromatogr. A 2002, 956, 129–138.
  • Roulet, C.-A.; Foradini, F. Simple and Cheap Air Change Rate Measurement Using CO2; Int. J. Vent. 2002, 1, 39–44.
  • Karthikeyan, S.; Balasubramanian, R. Rapid Extraction of Water Soluble Organic Compounds from Airborne Particulate Matter; Anal. Sci. 2005, 21, 1505–1508.
  • Rantakokko, P.; Mustonen, S.; Yritys, M.; Vartiainen, T. Ion Chromatographic Method for the Determination of Selected Inorganic and Organic Acids from Raw and Drinking Waters Using Suppressor Current Switching to Reduce the Background Noise; J. Liq. Chrom. Rel. Tech. 2004, 27, 829–842.
  • Zheng, J.; Ohata, M.; Furuta, N. Reversed Phase Liquid Chromatography with Mixed Ion Pair Reagents Coupled with ICPMS for the Direct Speciation Analysis of Selenium in Human Urine; J. Anal. At. Spectrom. 2002, 17, 730–735.
  • Chia, L.S.; Rahim, A.; Tay, D.B.H., Eds. The Biophysical Environment of Singapore; Singapore University Press: Singapore, 1991; 185–206.
  • Liu, L.-J.; Koutrakis, S.P.; Suh, H.H.; Mulik, J.D.; Burton, M. Use of Personal Measurements for Ozone Exposure Assessment: a Pilot Study; Environ. Health. Perspect. 1993, 101, 318–324.
  • Liu, L.-J.; Koutrakis, S.P.; Leech, J.; Broder, I. Assessment of Ozone Exposures in the Greater Metropolitan Toronto; J. Air & Waste Manage. Assoc . 1995, 45, 223–234.
  • Ministry of Health. Guidelines for the Prevention and Control of Infectious Diseases in Child Care Centres/Kindergartens/Pre-School Centres; Ministry of the Environment, Quarantine and Epidemiology Department. (Now under Ministry of Health, MOH): Singapore, 1998.
  • Chao, C.Y.H. Comparison between Indoor and Outdoor Contaminant Levels in Residential Building from Passive Sampler Study; Building Environ . 2001, 36, 997–1007.
  • Blondeau, P.; Lordache, V.; Poupard, O;. Genin, D. Allard, F. Relationship between Outdoor and Indoor Air Quality in Eight French Schools; Indoor Air 2005, 15, 2–12.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.