Ion-selective self-referencing probes for measuring specific ion flux

&
Pages 524-527 | Received 26 Apr 2011, Accepted 27 Apr 2011, Published online: 01 Sep 2011

References

  • Du Bois-Reymond E. Vorläufiger abriss einer untersuchung uber den sogenannten froschstrom und die electomotorischen fische. Ann Phy U Chem 1843; 58:1 - 30
  • Piccolino M. Animal electricity and the birth of electrophysiology: the legacy of Luigi Galvani. Brain Res Bull 1998; 46:381 - 407
  • Jaffe LF, Nuccitelli R. An ultrasensitive vibrating probe for measuring steady extracellular currents. J Cell Biol 1974; 63:614 - 628
  • Reid B, Nuccitelli R, Zhao M. Non-invasive measurement of bioelectric currents with a vibrating probe. Nat Protoc 2007; 2:661 - 669
  • Kühtreiber WM, Jaffe LF. Detection of extracellular calcium gradients with a calcium-specific vibrating electrode. J Cell Biol 1990; 110:1565 - 1573
  • Ryan PR, Newman IA, Shields B. Ion fluxes in corn roots measured by microelectrodes with ion-specific liquid membranes. J Memb Sci 1990; 53:59 - 69
  • Kochian LV, Shaft JE, Kühtreiber WM, Jaffe LF, Lucas WJ. Use of an extracellular; ion-selective; vibrating microelectrode system for the quantification of K+, H+ and Ca2+ fluxes in maize roots and maize suspension cells. Planta 1992; 188:601 - 610
  • Doughty JM, Langton PD. Measurement of chloride flux associated with the myogenic response in rat cerebral arteries. J Physiol 2001; 534.3:753 - 761
  • Messerli MA, Smith PJS, Lewis RC, Robinson KR. Chloride fluxes in lily pollen tubes: a critical reevaluation. Plant J 2004; 40:799 - 812
  • Molina AJ, Verzi MP, Birnbaum AD, Yamoah EN, Hammar K, Smith PJ, Malchow RP. Neurotransmitter modulation of extracellular H+ fluxes from isolated retinal horizontal cells of the skate. J Physiol 2004; 560:639 - 657
  • Marenzanaa M, Shipley AM, Squitierob P, Kunkelb JG, Rubinaccia A. Bone as an ion exchange organ: Evidence for instantaneous cell-dependent calcium efflux from bone not due to resorption. Bone 2005; 37:545 - 554
  • Ramos AC, Façanha AR, Feijó JA. Proton (H+) flux signature for the presymbiotic development of the arbuscular mycorrhizal fungi. New Phytol 2007; 178:177 - 188
  • Lew RR. Ionic currents and ion fluxes in Neurospora crassa hyphae. J Exp Bot 2007; 58:3475 - 3481
  • Vieira AC, Reid B, Cao L, Mannis MJ, Schwab IR, Zhao M. Ionic components of electric current at rat corneal wounds. PLoS One 2011; 6:17411
  • Smith PJS. Non-invasive ion probes—tools for measuring transmembrane ion flux. Nature 1995; 378:645 - 646
  • Smith PJS, Hammar K, Porterfield DM, Sanger RH, Trimarchi JR. Self-referencing, non-invasive, ion selective electrode for single cell detection of trans-plasma membrane calcium flux. Microsc Res Technique 1999; 46:398 - 417
  • Smith PJS, Sanger RH, Messerli MA. Michael AC, Borland LM. Principles, development and applications of self-referencing electrochemical microelectrodes to the determination of fluxes at cell membranes. Electrochemical Methods for Neuroscience 2007; Boca Raton CRC Press 18
  • Porterfield DM. Measuring metabolism and biophysical flux in the tissue, cellular and sub-cellular domains: recent developments in self-referencing amperometry for physiological sensing. Biosens Bioelectron 2007; 22:1186 - 1196
  • McLamore ES, Mohanty S, Shi J, Claussen J, Jedlicka SS, Rickus JL, Porterfield DM. A self-referencing glutamate biosensor for measuring real time neuronal glutamate flux. J Neurosci Methods 2010; 189:14 - 22
  • Chatni MR, Porterfield DM. Self-referencing optrode technology for non-invasive real-time measurement of biophysical flux and physiological sensing. Analyst 2009; 134:2224 - 2232
  • McLamore ES, Jaroch D, Chatni MR, Porterfield DM. Self-referencing optrodes for measuring spatially resolved, real-time metabolic oxygen flux in plant systems. Planta 2010; 232:1087 - 1099
  • McLamore ES, Shi J, Jaroch D, Claussen JC, Uchida A, Jiang Y, et al. A self referencing platinum nanoparticle decorated enzyme-based microbiosensor for real time measurement of physiological glucose transport. Biosens Bioelectron 2011; 26:2237 - 2245