Enhancement of Critical Characteristics of Aged Transformer Oil using Regenerative Additives

, , , &
Pages 77-86 | Received 05 Feb 2013, Accepted 08 Mar 2013, Published online: 16 Nov 2015

Reference

  • ASTM, 2012, ASTM D93 Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester.
  • ASTM, 2011, ASTM D445 Standard Test Method for Kinematic Viscosity of Transparent and Opaque Liquids (and Calculation of Dynamic Viscosity).
  • Carelli, A. A., Franco, I. C. & Crapiste, G. H. 2005, “Effectiveness of added natural antioxidants in sunflower oil”, Grasas y Aceites, Vol. 56, No. 4, pp. 303–310.
  • Du, Y., Yuzhen, L., Li, C., Chen, M., Zhong, Y., Zhou, J., Li, X. & Zhou, Y. 2012, “Effect of Semiconductive Nanoparticles on Insulating Performances of Transformer Oil”, IEEE Transactions on Dielectric and Electrical Insulation, Vol. 19, No. 3, pp. 770–776.
  • Gray, I. A. R. 2008, “Oxidation Inhibitors for Insulating Oils”, Transformer Chemistry Services.
  • IEEE, 1995, IEEE Standard C57.91 Guide for loading Mineral-oil-immersed Transformers, Annex I: Transformer Insulation Life.
  • IEEE, 2003, IEC 60156 Third edition, 2003-11, Insulating liquids — Determination of the breakdown voltage at power frequency — Test method.
  • Karthik, R. & Sree Renga Raja, T. 2012, “Investigations of Transformer Oil Characteristics”, IEEJ-TEE, Vol. 7, pp. 369–374.
  • Karthik, R., Sree Renga Raja, T. & Madavan, S. 2012, “Enhancement of Critical Characteristics of Transformer Oil Using Nano Materials”, Arabian Journal of Science and Engineering, Springer Publications.
  • Koch, M., Fischer, M. & Tenbohlen, S. 2007, “The Breakdown Voltage of Insulation Oil Under The Influences of Humidity, Acidity, Particles and Pressure”, International Conference APTADM, Wroclaw, Poland.
  • Kopcansky, P., Tomco, L., Marton, K., Koneracka, M., Potocova, I. & Timko, M. 2005, “The DC Dielectric Breakdown Strength of Magnetic Fluids Based on Transformer Oil”, Journal of Magnetism and Magnetic Materials, Vol. 289, pp. 415–418.
  • McShane, C. 2000, “New Safety Dielectric Coolants for Distribution and Power Transformers”, IEEE Industry Applications Magazine, Vol. 6, pp. 24–32.
  • Okabe, S., Kohtoh, M. & Amimoto, T. 2010, “Suppression of Increase in Electrostatic Charging Tendency of Insulating Oil by Aging Used for Power Transformer Insulation" , IEEE Transactions on Dielectrics and Electrical Insulation, Vol. 17, No. 1.
  • Rubalya Valantina, S. & Neelamega, P. 2012, “Antioxidant potential in vegetable oil”, Research Journal of Chemistry and Environment, India, Vol. 16, No. 2.
  • Sanghi, R. 2003, “Chemistry behind the life of a Transformer”, General Article: Resonance, Vol. 8, No. 6, pp. 17–23.
  • Segal, V., Hjortsberg, A., Rabinovich, A., Nattrass, D. & Raj, K. 1998, “AC (60Hz) and Impulse Breakdown Strength of a Colloidal Fluid Based on Transformer Oil And Magnetite Nanoparticles”, IEEE International Symposium on Electrical Insulation, Arlington, VA, USA, pp. 619–622.
  • Segal, V., Rabinovich, A., Nattrass, D., Raj, K. & Nunes, A. 2000, “Experimental Study of Magnetic Colloidal Fluids Behavior in Power Transformers”, Journal of Magnetism and Magnetic Materials, Vol. 215, pp. 513–515.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.