Supplemental material
Acta Orthopaedica
Volume 83, 2012 - Issue 2
Open access
1,093
Views
24
CrossRef citations to date
0
Altmetric
Original papers
RSA prediction of high failure rate for the uncoated Interax TKA confirmed by meta-analysis
Bart G PijlsDepartment of OrthopaedicsCorrespondence[email protected]
, Marc J NieuwenhuijseDepartment of Orthopaedics
, Jan W SchoonesWalaeus Library
, Saskia MiddeldorpDepartment of Clinical Epidemiology,
Leiden University Medical Centre, Leiden,
, Edward R ValstarDepartment of Orthopaedics;Department of Biomechanical Engineering,
Faculty of Mechanical, Maritime and Materials Engineering, TU Delft; the Netherlands
& Rob G H H NelissenDepartment of Orthopaedics
Pages 142-147
|
Received 10 Jun 2011, Accepted 29 Jan 2012, Published online: 24 Apr 2012
Related Research Data
Publication and related bias in meta-analysis : power of statistical tests and prevalence in the literature
Source:
Elsevier BV
284 press-fit Kinemax total knee arthroplasties followed for 10 years: Poor survival of uncemented prostheses
Source:
Medical Journals Sweden AB
Continued stabilization of trabecular metal tibial monoblock total knee arthroplasty components at 5 years-measured with radiostereometric analysis.
Source:
Medical Journals Sweden AB
Uncemented HA-coated implant is the optimum fixation for TKA in the young patient.
Source:
Ovid Technologies (Wolters Kluwer Health)
[Knee endoprosthesis: clinical aspects].
Source:
Springer Science and Business Media LLC
LESSONS OF A HIP FAILURE
Source:
BMJ
A method for the study of the kinematics of the skeletal system
Source:
Informa UK Limited
Evaluation of micromotion in cemented vs uncemented knee arthroplasty in osteoarthrosis and rheumatoid arthritis
Source:
Elsevier BV
Does early micromotion of femoral stem prostheses matter? 4-7-year stereoradiographic follow-up of 84 cemented prostheses
Source:
British Editorial Society of Bone & Joint Surgery
The Effect of Hydroxyapatite on the Micromotion of Total Knee Prostheses. A Prospective, Randomized, Double-Blind Study*
Source:
Ovid Technologies (Wolters Kluwer Health)
Roentgen stereophotogrammetric analysis as a predictor of mechanical loosening of knee prostheses
Source:
British Editorial Society of Bone & Joint Surgery
Reference bias in reports of drug trials.
Source:
BMJ
Early migration of prostheses related to long-term survivorship. Comparison of tibial components in knee replacement
Source:
British Editorial Society of Bone & Joint Surgery
A randomized radiostereometric study comparing porous-coated, hydroxyapatite-coated and cemented tibial components over 5 years
Source:
Medical Journals Sweden AB
Related research
People also read lists articles that other readers of this article have read.
Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.
Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.