1,983
Views
22
CrossRef citations to date
0
Altmetric
Research Article

Evaluation of setup accuracy for NSCLC patients; studying the impact of different types of cone-beam CT matches based on whole thorax, columna vertebralis, and GTV

, , , &
Pages 1184-1191 | Received 20 May 2010, Accepted 08 Jun 2010, Published online: 13 Sep 2010
 

Abstract

Purpose. The aim of this study is to evaluate the patient setup accuracy by investigating the impact of different types of CBCT matches, performed with 3 (translations only) or 6 (including rotations) degrees-of-freedom (DOF). The purpose is also to calculate and compare CTV to PTV margins based on the various CBCT matches, setups using 2D kV planar imaging or setups using skin markers only (non-IGRT). Material and methods. Setup images from 16 NSCLC patients with weekly CBCT and daily 2D kV planar imaging were analyzed retrospectively. The CBCT matches were based on the columna vertebralis (CV), the whole thorax (WT) and the soft tissue (ST) delineated GTV, where the ST match was chosen as reference. Thus the translational and rotational shifts in three dimensions were assessed. Finally, setup margins were calculated using van Herk's margin recipe. Results. For 80% of the investigated 3 DOF/2D kV CV setups, the translational shifts were within [−3, 2] mm for all three directions. Corresponding values for the 6 DOF/non-IGRT CV and the 6 DOF/non-IGRT ST matches were [−5, 8] mm. Furthermore, 80% of all setups were within ± 2° for pitch-, roll- and yaw-rotations, and none exceeded 5°. The calculated margins for non-IGRT, about 10 mm, were reduced to approximately 4 mm, regardless of using IGRT setup by CBCT or 2D kV imaging on CV. However, if using WT CBCT setup, the margin in LNG direction was slightly larger, approximately 6 mm. Conclusion. IGRT for NSCLC is an essential tool for margin reduction, since patient setups based on IGRT leads to approximately half the margin sizes compared to non-IGRT setups. Both CBCT and 2D kV planar imaging yields approximately the same margins for CV/ST matches. The magnitudes of the patient rotations were <5°.

Acknowledgements

The results of this study were presented as a poster at the Acta Oncologica Symposium on biology-guided adaptive radiotherapy, BIGART 2010, in Aarhus, Denmark, on May 26–28, 2010.

Declaration of interest: The authors report no conflicts of interest. The authors alone are responsible for the content and writing of the paper.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.