1,697
Views
18
CrossRef citations to date
0
Altmetric
Research Article

Bipolar radiofrequency ablation with 2 × 2 electrodes as a building block for matrix radiofrequency ablation: Ex vivo liver experiments and finite element method modelling

, , , , , , & show all
Pages 649-665 | Received 02 Nov 2014, Accepted 24 Apr 2015, Published online: 09 Jul 2015

Keep up to date with the latest research on this topic with citation updates for this article.

Read on this site (2)

Zheng Li, Kai Zhang, Shu-Mei Lin, Deng-Hai Mi, Nong Cao, Zhi-Zhen Wen & Zhong-Xin Li. (2017) Radiofrequency ablation combined with percutaneous ethanol injection for hepatocellular carcinoma: a systematic review and meta-analysis. International Journal of Hyperthermia 33:3, pages 237-246.
Read now
Kazuyuki Saito & Koichi Ito. (2017) Preliminary investigation of numerical estimation of coagulated region generated by interstitial microwave antenna. International Journal of Hyperthermia 33:1, pages 69-73.
Read now

Articles from other publishers (16)

Ean H. Ooi & Ean T. Ooi. (2021) Unidirectional ablation minimizes unwanted thermal damage and promotes better thermal ablation efficacy in time-based switching bipolar radiofrequency ablation. Computers in Biology and Medicine 137, pages 104832.
Crossref
Shelley Yap, Ean H. Ooi, Ji J. Foo & Ean T. Ooi. (2021) Comparisons between impedance-based and time-based switching bipolar radiofrequency ablation for the treatment of liver cancer. Computers in Biology and Medicine 134, pages 104488.
Crossref
Shelley Yap, Ean H. Ooi, Ji J. Foo & Ean T. Ooi. (2021) Bipolar radiofrequency ablation treatment of liver cancer employing monopolar needles: A comprehensive investigation on the efficacy of time-based switching. Computers in Biology and Medicine 131, pages 104273.
Crossref
Iwan Paolucci, Raluca-Maria Sandu, Pascale Tinguely, Corina Kim-Fuchs, Martin Maurer, Daniel Candinas, Stefan Weber & Anja Lachenmayer. 2021. Liver Pathology. Liver Pathology.
Huijun Gu, Zhiqin Qian & Zheng Fang. (2020) Measurement of Electrical and Thermal Conductivity After Electoporation In Vivo. Measurement of Electrical and Thermal Conductivity After Electoporation In Vivo.
Stefaan Mulier, Ricardo Possebon, Yansheng Jiang, Jacques Jamart, Chong Wang, Yi Miao, Tongfu Yu, Kuirong Jiang, Yuanbo Feng, Guy Marchal, Luc Michel & Yicheng Ni. (2020) Radiofrequency ablation with four electrodes as a building block for matrix radiofrequency ablation: Ex vivo liver experiments and finite element method modelling. Influence of electric and activation mode on coagulation size and geometry. Surgical Oncology 33, pages 145-157.
Crossref
Shelley Yap, Jason K.K. Cheong, Ji J. Foo, Ean T. Ooi & Ean H. Ooi. (2020) The effects of the no-touch gap on the no-touch bipolar radiofrequency ablation treatment of liver cancer: A numerical study using a two compartment model. Applied Mathematical Modelling 78, pages 134-147.
Crossref
Zhen Tian, Tong Dong, Yanyan Cheng, Jian Hu & Qun Nan. (2019) A Treatment Planning of Radio Frequency Ablation for Spinal Tumor. International Journal of Computational Methods 16:03, pages 1842005.
Crossref
Y.L. Shao, H.L. Leo & K.J. Chua. (2018) Studying of the thermal performance of a hybrid cryo-RFA treatment of a solid tumor. International Journal of Heat and Mass Transfer 122, pages 410-420.
Crossref
Y.L. Shao, B. Arjun, H.L. Leo & K.J. Chua. (2017) A computational theoretical model for radiofrequency ablation of tumor with complex vascularization. Computers in Biology and Medicine 89, pages 282-292.
Crossref
Yansheng Jiang, Ricardo Possebon, Stefaan Mulier, Chong Wang, Feng Chen, Yuanbo Feng, Qian Xia, Yewei Liu, Ting Yin, Raymond Oyen & Yicheng Ni. (2017) A methodology for constraining power in finite element modeling of radiofrequency ablation. International Journal for Numerical Methods in Biomedical Engineering 33:7, pages e2834.
Crossref
Franz G. M. Poch, Christian Rieder, Hanne Ballhausen, Verena Knappe, Jörg Peter Ritz, Ole Gemeinhardt, Martin E. Kreis & Kai S. Lehmann. (2017) Finding Optimal Ablation Parameters for Multipolar Radiofrequency Ablation. Surgical Innovation 24:3, pages 205-213.
Crossref
Y.L. Shao, B. Arjun, H.L. Leo & K.J. Chua. (2017) Nano-assisted radiofrequency ablation of clinically extracted irregularly-shaped liver tumors. Journal of Thermal Biology 66, pages 101-113.
Crossref
Y.L. Shao, H.L. Leo & K.J. Chua. (2017) Studying the thermal performance of a bipolar radiofrequency ablation with an improved electrode matrix system: In vitro experiments and modelling. Applied Thermal Engineering 116, pages 623-635.
Crossref
Janine Matschek, Eric Bullinger, Friedrich von Haeseler, Martin Skalej & Rolf Findeisen. (2017) Mathematical 3D modelling and sensitivity analysis of multipolar radiofrequency ablation in the spine. Mathematical Biosciences 284, pages 51-60.
Crossref
Ole Gemeinhardt, Franz G.M. Poch, Bernhard Hiebl, Urte Kunz-Zurbuchen, Giuliano M. Corte, Stefan F. Thieme, Janis L. Vahldiek, Stefan M. Niehues, Martin E. Kreis, Robert Klopfleisch & Kai S. Lehmann. (2017) Comparison of bipolar radiofrequency ablation zones in an in vivo porcine model: Correlation of histology and gross pathological findings. Clinical Hemorheology and Microcirculation 64:3, pages 491-499.
Crossref

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.