87
Views
19
CrossRef citations to date
0
Altmetric
Original Research

Remote ischemic conditioning improves coronary microcirculation in healthy subjects and patients with heart failure

, , , , , & show all
Pages 1175-1181 | Published online: 27 Aug 2014

Abstract

Background

Remote ischemic conditioning (RIC) is a treatment modality that suppresses inflammation and improves endothelial function, which are factors involved in the pathogenesis of heart failure (HF) with reduced left ventricular ejection fraction. Coronary flow reserve (CFR) is a physiological index of coronary microcirculation and is noninvasively measured by transthoracic Doppler echocardiography (TTDE). This study aimed to investigate the effects of RIC on CFR in healthy subjects and patients with HF, through the assessment by TTDE.

Methods

Ten patients with HF with left ventricular ejection fraction of less than 40%, and ten healthy volunteers were enrolled in this study. RIC treatment was performed twice a day for 1 week. Our custom-made RIC device was programmed to automatically conduct 4 cycles of 5 minutes inflation and 5 minutes deflation of a blood pressure cuff to create intermittent arm ischemia. CFR measurements and laboratory tests were examined before, and after 1 week of RIC treatment.

Results

One week of RIC treatment was well tolerated in both groups. RIC treatment increased CFR from 4.0±0.9 to 4.6±1.3 (mean ± standard deviation) in healthy subjects (P=0.02), and from 1.9±0.4 to 2.3±0.7 in patients with HF (P=0.03), respectively. Systolic blood pressure in healthy subjects, and heart rate in HF patients decreased after RIC treatment (both P<0.01).

Conclusion

This study demonstrated that a 1 week course of RIC treatment improved coronary microcirculation in healthy subjects and patients with HF associated with reduced left ventricular ejection fraction.

Introduction

Heart failure (HF), a syndrome resulting from a variety of cardiac injuries, leads to significant morbidity and mortality. It is now recognized that HF is a highly complex multifactor disorder in which a number of physiological systems participate. Patients with HF associated with reduced left ventricular (LV) ejection fraction (EF) have elevated inflammatory status and impaired endothelial function, and these factors appear to have prognostic implications.Citation1Citation4 Despite advances in drug and/or device therapy for chronic HF with reduced LVEF, outcomes at the community level remain suboptimal.Citation5,Citation6 These unsatisfactory results warrant investigation of further therapeutic strategies to treat HF patients in their daily lives.

Remote ischemic conditioning (RIC) is a noninvasive, simple procedure whereby repeated brief episodes of ischemia at a site distant from the heart protect the heart from cellular injury. A number of clinical studies have confirmed positive cardioprotective effects of RIC in the setting of myocardial infarction,Citation7 cardiacCitation8Citation10 and non-cardiac surgery,Citation11 and percutaneous coronary intervention.Citation12 The mechanisms of RIC include suppressed inflammationCitation8,Citation13,Citation14 and improved endothelial function, which are common pathogenic mechanisms in HF.Citation15,Citation16 We therefore hypothesized that RIC can provide beneficial effects on microvascular function in patients with HF. This study therefore aimed to investigate the effects of 1 week of RIC treatment on coronary flow reserve (CFR) as a physiological index of coronary microcirculation in both healthy subjects and patients with chronic HF with reduced LVEF, through the assessment by transthoracic Doppler echocardiography (TTDE).

Methods

Study population

This study consisted of ten healthy subjects (age, 31±4 years; ten men) and ten patients with chronic HF (age, 64±9 years; nine men, and one woman). Ten patients with HF (ischemic cardiomyopathy in six patients, and idiopathic dilated car-diomyopathy in four patients) whose morbidity was stable at the time of study enrollment were recruited. Patients were eligible for the study if they were hemodynamically stable, had decreased exercise tolerance, and had an LVEF of less than 40%. The exclusion criteria were as follows: more than moderate valvular heart disease; a history of peripheral arterial disease; chronic kidney disease (estimated glomerular filtration rate <60 mL/min/1.73 mm2) including maintenance hemodialysis; and the presence of other serious systemic diseases. Patients with unstable hemodynamics, or with obstructive narrowing (≥50%) in the left anterior descending (LAD) artery as confirmed by coronary angiography were also excluded because of ethical considerations regarding the safety of RIC.

Ten male physicians and technicians with normal echocardiographic findings, and no history of cardiovascular disease served as healthy subjects. To investigate the effect of repeated hyperemic stimulation with adenosine triphosphate (ATP) on CFR, TTDE examinations were conducted 1 week apart without RIC treatment, as a control study. Premenopausal women were not enrolled considering that the menstrual cycle might influence CFR.Citation17 This study was approved by the Institutional Review Board of the Osaka Ekisaikai Hospital, and the subjects gave informed consent.

Study protocol

CFR and LV function were measured using TTDE before and after a 1 week course of RIC treatment. These TTDE examinations were performed at approximately the same time of day, considering circadian variation in CFR.Citation18 Blood samples for the assessment of white blood cell counts, fasting lipids levels, and high-sensitive C-reactive protein levels, were performed immediately before each TTDE examination. Levels of high-sensitive tumor necrosis factor-α, high-sensitive interleukin-6, high-sensitive troponin T, and brain natriuretic peptide were assessed only in HF patients.

In each RIC treatment, three steps were performed by the subjects. First, the subject placed the cuff on their arm; second, they pushed the “run” button; and third, they removed the cuff after ending 4 cycles of inflation and deflation. RIC treatment was repeated each morning and evening for 1 week. In a supine position, cuffs placed on both right, and left upper arms were inflated to 200 mmHg pressure for 5 minutes (min). After 5 min inflation, each cuff was deflated at the same time. Four cycles of 5 min inflation and 5 min deflation of the blood pressure cuffs were automatically performed by our custom-made equipment (). The system also counted four cycles of inflation and deflation and provided an alert when the four cycles ended. A physician (YK) confirmed that the subjects used the system correctly.

Figure 1 Our custom-made RIC device, showing the body of the system (left) and 2 blood-pressure cuffs connected to the system (right).

Note: Four cycles of inflation and deflation of the blood pressure cuff were programmed in the system, which enabled automatic RIC treatment.
Abbreviation: RIC, remote ischemic conditioning.
Figure 1 Our custom-made RIC device, showing the body of the system (left) and 2 blood-pressure cuffs connected to the system (right).

Echocardiography

TTDE examination was performed using Vivid 7 (GE Healthcare UK Ltd, Little Chalfont, UK) in the standard manner.Citation19 LV end-diastolic and systolic volumes were obtained using the Simpson’s method and indexed by body surface area. LVEF was then calculated. Pulsed-wave Doppler examination of mitral inflow was performed to measure peak velocity (E). Early diastolic mitral annular velocity (e’) was also measured from tissue Doppler imaging in the septal wall. The ratio of E to e’ was then calculated (E/e’).

For the measurement of CFR, a modified foreshortened two-chamber view was applied to explore the flow in the distal portion of the LAD. If the angle between color flow and the Doppler beam was >20%, angle correction was performed. Coronary blood flow velocity was obtained at baseline and after intravenous infusion of ATP at a rate of 0.14 mg/kg per min for 2 min to produce hyperemia. Mean diastolic flow velocity (MDFV) was measured by tracing the contour of the spectral Doppler signal. CFR was calculated as the ratio of hyperemic to basal MDFV. For each variable in the CFR measurements, the values of three cycles were averaged. Expert sonographers who had >5 years experience in echocardiography performing approximately 100 CFR examinations, performed the TTDE examinations. They were blinded to the other information of each patient.

Statistical analysis

Values were expressed as the mean ± standard deviation. Comparisons of laboratory and echocardiographic data before and after RIC were made with a paired t-test. Heart rate, blood pressure, and MDFV after ATP infusion in pre-and post-RIC treatment were evaluated by two-way repeated measures analysis of variance, testing for RIC effects, ATP effects, and interactions. Differences were considered significant at P<0.05.

Results

Clinical characteristics of healthy subjects and patients with HF are summarized in . RIC was completed and well tolerated in all healthy subjects and patients with HF. No significant hemodynamic or mechanical complications were observed at the end of the 1 week procedure.

Table 1 Clinical characteristics of study participants

Significant increases in CFR were observed in both healthy subjects (4.0±0.9 to 4.6±1.2, P=0.02) and patients with HF (1.9±0.4 to 2.3±0.7, P=0.03), as shown in . Hemodynamics and MDFV values before and after RIC in each group are shown in . In two-way repeated measures analysis of variance, systolic blood pressure decreased after RIC treatment in healthy subjects (P=0.001). Heart rate decreased after RIC treatment in HF patients (P=0.01). MDFV increased during hyperemia in both groups (both P<0.001), whereas there were no significant interactions in terms of RIC.

Table 2 Hemodynamics and MDFV before and after RIC treatment

Figure 2 Changes in CFR after 1 week of RIC treatment in healthy subjects and HF patients.

Abbreviations: CFR, coronary flow reserve; HF, heart failure; RIC, remote ischemic conditioning.
Figure 2 Changes in CFR after 1 week of RIC treatment in healthy subjects and HF patients.

Other echocardiographic parameters measured before and after RIC are shown in . There were no statistical differences in echocardiographic parameters before and after RIC in either group, except for LV end-systolic volume in healthy subjects (19±3 mL/m2 to 22±4 mL/m2, P=0.01). The laboratory data before and after RIC are summarized in . In patients with HF, tumor necrosis factor-α (P=0.2), interleukin-6 (P=0.1), troponin-T (P=0.2), and brain natriuretic peptide levels (P=0.07) tended to decrease after RIC treatment, but these reductions did not reach statistical significance.

Table 3 Echocardiographic results before and after RIC treatment

Table 4 Laboratory data before and after RIC treatment

In the control study (examinations without RIC treatment), there were no significant differences in any laboratory data, hemodynamics, or echocardiographic results before and after 1 week, except for MDFV before and after ATP infusion (P<0.001). These findings are summarized in .

Table 5 Hemodynamics, echocardiographic results and laboratory data before and after 1 week without RIC treatment in healthy subjects

Discussion

This study demonstrated that a 1 week course of RIC treatment improved the status of coronary microcirculation in healthy subjects and patients with HF associated with reduced LVEF without any adverse effects, supporting the widespread use of RIC in the daily lives of HF patients.

Developments in TTDE technology have enabled visualization of coronary blood flow and assessment of CFR in the LAD. This technique has been validated by the intracoronary Doppler flow wire technique advanced into the coronary vessels, leading to the accurate diagnosis of physiologically obstructive coronary artery disease.Citation20,Citation21 Furthermore, because of the noninvasive, relatively inexpensive, and physiological nature of TTDE, TTDE-derived CFR measurement is open to innovative applications, including serial measurement of coronary microvascular function,Citation18,Citation22,Citation23 because CFR is considered to be an integrated parameter that reflects the severity of coronary microvascular dysfunction. We therefore used TTDE-derived CFR to evaluate the effect of RIC on coronary microcirculation in patients with HF.

Recently, measurement of TTDE-derived CFR has gained prognostic significance for stratifying patients at risk of developing cardiovascular diseases, beyond the assessment of individual traditional atherosclerotic risk factors. Several investigations have shown that CFR was reduced even in the absence of obstructive coronary narrowing, resulting in long-term cardiovascular events in patients with coronary risk factors, such as hypertension,Citation24 diabetes,Citation25 and chronic kidney disease.Citation26 Importantly, reduced CFR was strongly associated with the development of HF, rather than coronary artery events.Citation27 These observations indicate the potential of CFR as a therapeutic target for improving long-term outcomes in patients with impaired LV function as well as the close relationship between impaired coronary microcirculation and the future functional capability of the myocardium.

Ischemic preconditioning was first described in 1986 in a canine model of myocardial infarction.Citation28 Because ischemic preconditioning has systemic effects that result in protection from ischemic-reperfusion injury for tissues remote from those undergoing preconditioning, RIC offers a clinically relevant stimulus.Citation29 RIC can prevent adverse consequences of ischemia in potentially vulnerable target organs. Several mechanisms for RIC have been proposed in experimental settings, all of which are broadly related to the release of humoral mediators, including adenosine,Citation30 bradykinin,Citation31 and opioids,Citation32 and the autonomic nervous system.Citation33 Subsequent studies in humans have confirmed that RIC decreased inflammationCitation8,Citation13,Citation18 and improved endothelial function.Citation15,Citation16 Moreover, enhanced inflammatory status and endothelial dysfunction are reported to be involved in the pathogenesis of HF.Citation1Citation4 This study demonstrated that a 1 week course of RIC treatment resulted in favorable effects in HF patients with reduced LVEF, through the improvement of coronary microcirculation. In addition, our custom-made RIC device was programmed to administer four cycles of inflation and deflation of blood pressure cuffs; this device was to be used by the patients themselves. The findings of the present study indicated that a simple RIC device would enhance the use of RIC as a self-care HF treatment for inpatients as well as individuals outside the hospital setting, including home-care patients.

Study limitations

This study had several limitations. First, the sample size was small (n=20), which may reasonably explain that changes in some biomarkers did not reach statistical significance. In addition, this study focused on the investigation of the effect of a 1 week course of RIC treatment on LV function in healthy subjects and HF patients with reduced LVEF. The long-term effects of RIC treatment and their impact on clinical outcomes remain unknown, especially in patients with HF with preserved EF. Further study of larger populations with long-term follow-up should be conducted to confirm the results of the present study. Second, statistically significant decreases in systolic blood pressure and increases in LV end-systolic volume were observed following the RIC procedure in healthy subjects. Although the degree of change was too subtle to cause any systemic effects, their alterations should be carefully interpreted. Third, all subjects completed 1 week of RIC treatment without any complications based on self-reports. The RIC system should be improved to precisely record when it is activated. Finally, CFR was measured by TTDE method in the LAD alone, and the effect of RIC on circulation in other coronary vessels was not estimated. This was because the success rates in obtaining adequate coronary flow velocity in the LAD were higher than those in other coronary vessels.Citation34 Concomitant measurement of CFR in an adjacent normal vessel may provide more mechanistic insights into the findings of this study.

Conclusion

This study demonstrated that a 1 week course of RIC treatment improved the status of coronary microcirculation in healthy subjects and patients with HF with no adverse effects, supporting the widespread use of RIC in the daily lives of HF patients.

Disclosure

The authors report no conflicts of interest in this work.

References

  • Drexler H Hayoz D Munzel T Endothelial function in chronic congestive heart failure Am J Cardiol 1992 69 19 1596 1601 1598876
  • Aukrust P Ueland T Lien E Cytokine network in congestive heart failure secondary to ischemic or idiopathic dilated cardiomyopathy Am J Cardiol 1999 83 3 376 382 10072227
  • Tousoulis D Charakida M Stefanadis C Inflammation and endothelial dysfunction as therapeutic targets in patients with heart failure Int J Cardiol 2005 100 3 347 353 15837076
  • Marti CN Gheorghiade M Kalogeropoulos AP Georgiopoulou VV Quyyumi AA Butler J Endothelial dysfunction, arterial stiffness, and heart failure J Am Coll Cardiol 2012 60 16 1455 1469 22999723
  • Fonarow GC Peterson ED Heart failure performance measures and outcomes: real or illusory gains JAMA 2009 302 7 792 794 19690314
  • Bueno H Ross JS Wang Y Trends in length of stay and short-term outcomes among Medicare patients hospitalized for heart failure, 1993–2006 JAMA 2010 303 21 2141 2147 20516414
  • Bøtker HE Kharbanda R Schmidt MR Remote ischaemic conditioning before hospital admission, as a complement to angioplasty, and effect on myocardial salvage in patients with acute myocardial infarction: a randomised trial Lancet 2010 375 9716 727 734 20189026
  • Cheung MM Kharbanda RK Konstantinov IE Randomized controlled trial of the effects of remote ischemic preconditioning on children undergoing cardiac surgery: first clinical application in humans J Am Coll Cardiol 2006 47 11 2277 2282 16750696
  • Hausenloy DJ Mwamure PK Venugopal V Effect of remote ischaemic preconditioning on myocardial injury in patients undergoing coronary artery bypass graft surgery: a randomised controlled trial Lancet 2007 370 9587 575 579 17707752
  • Thielmann M Kottenberg E Kleinbongard P Cardioprotective and prognostic effects of remote ischaemic preconditioning in patients undergoing coronary artery bypass surgery: a single-centre randomised, double-blind, controlled trial Lancet 2013 382 9892 597 604 23953384
  • Ali ZA Callaghan CJ Lim E Remote ischemic preconditioning reduces myocardial and renal injury after elective abdominal aortic aneurysm repair: a randomized controlled trial Circulation 2007 116 Suppl 11 I98 I105 17846333
  • Hoole SP Heck PM Sharples L Cardiac Remote Ischemic Preconditioning in Coronary Stenting (CRISP Stent) Study: a prospective, randomized control trial Circulation 2009 119 6 820 827 19188504
  • Harkin DW Barros D’Sa AA McCallion K Hoper M Campbell FC Ischemic preconditioning before lower limb ischemia – reperfusion protects against acute lung injury J Vasc Surg 2002 35 6 1264 1273 12042740
  • Konstantinov IE Arab S Kharbanda RK The remote ischemic preconditioning stimulus modifies inflammatory gene expression in humans Physiol Genomics 2004 19 1 143 150 15304621
  • Zhao ZQ Corvera JS Halkos ME Inhibition of myocardial injury by ischemic postconditioning during reperfusion: comparison with ischemic preconditioning Am J Physiol Heart Circ Physiol 2003 285 2 H579 H588 12860564
  • Loukogeorgakis SP Panagiotidou AT Broadhead MW Donald A Deanfield JE MacAllister RJ Remote ischemic preconditioning provides early and late protection against endothelial ischemia-reperfusion injury in humans: role of the autonomic nervous system J Am Coll Cardiol 2005 46 3 450 456 16053957
  • Hirata K Shimada K Watanabe H Modulation of coronary flow velocity reserve by gender, menstrual cycle and hormone replacement therapy J Am Coll Cardiol 2001 38 7 1879 1884 11738288
  • Fukuda S Shimada K Maeda K Circadian variation in coronary flow velocity reserve and its relation to α1-sympathetic activity in humans Int J Cardiol 2012 157 2 216 220 21194761
  • Lang RM Bierig M Devereux RB Recommendations for chamber quantification: a report from the American Society of Echocardiography’s Guidelines and Standards Committee and the Chamber Quantification Writing Group, developed in conjunction with the European Association of Echocardiography, a branch of the European Society of Cardiology J Am Soc Echocardiogr 2005 18 12 1440 1463 16376782
  • Hozumi T Yoshida K Akasaka T Noninvasive assessment of coronary flow velocity and coronary flow velocity reserve in the left anterior descending coronary artery by Doppler echocardiography: comparison with invasive technique J Am Coll Cardiol 1998 32 5 1251 1259 9809933
  • Caiati C Montaldo C Zedda N Bina A Iliceto S New noninvasive method for coronary flow reserve assessment: contrast-enhanced transthoracic second harmonic echo Doppler Circulation 1999 99 6 771 778 9989962
  • Fukuda S Shimada K Kawasaki T “Passive exercise” using whole body periodic acceleration: effects on coronary microcirculation Am Heart J 2010 159 4 620 626 20362721
  • Kubo T Fukuda S Hirata K Comparison of coronary microcirculation in female nurses after day-time versus night-time shifts Am J Cardiol 2011 108 11 1665 1668 21880287
  • Cortigiani L Rigo F Galderisi M Diagnostic and prognostic value of Doppler echocardiographic coronary flow reserve in the left anterior descending artery in hypertensive and normotensive patients [corrected] Heart 2012 97 21 1758 1765 21835758
  • Cortigiani L Rigo F Gherardi S Additional prognostic value of coronary flow reserve in diabetic and nondiabetic patients with negative dipyridamole stress echocardiography by wall motion criteria J Am Coll Cardiol 2007 50 14 1354 1361 17903635
  • Nakanishi K Fukuda S Shimada K Prognostic value of coronary flow reserve on long-term cardiovascular outcomes in patients with chronic kidney disease Am J Cardiol 2013 112 7 928 932 23800551
  • Nakanishi K Fukuda S Shimada K Impaired coronary flow reserve as a marker of microvascular dysfunction to predict long-term cardiovascular outcomes, acute coronary syndrome and the development of heart failure Circ J 2012 76 8 1958 1964 22640984
  • Murry CE Jennings RB Reimer KA Preconditioning with ischemia: a delay of lethal cell injury in ischemic myocardium Circulation 1986 74 5 1124 1136 3769170
  • Przyklenk K Bauer B Ovize M Kloner RA Whittaker P Regional ischemic ‘preconditioning’ protects remote virgin myocardium from subsequent sustained coronary occlusion Circulation 1993 87 3 893 899 7680290
  • Pell TJ Baxter GF Yellon DM Drew GM Renal ischemia preconditions myocardium: role of adenosine receptors and ATP-sensitive potassium channels Am J Physiol 1998 275 5 Pt 2 H1542 H1547 9815059
  • Schoemaker RG van Heijningen CL Bradykinin mediates cardiac preconditioning at a distance Am J Physiol Heart Circ Physiol 2000 278 5 H1571 H1576 10775135
  • Patel HH Moore J Hsu AK Gross GJ Cardioprotection at a distance: mesenteric artery occlusion protects the myocardium via an opioid sensitive mechanism J Mol Cell Cardiol 2002 34 10 1317 1323 12392992
  • Wolfrum S Schneider K Heidbreder M Nienstedt J Dominiak P Dendorfer A Remote preconditioning protects the heart by activating myocardial PKCepsilon-isoform Cardiovasc Res 2002 55 3 583 589 12160956
  • Murata E Hozumi T Matsumura Y Coronary flow velocity reserve measurement in three major coronary arteries using transthoracic Doppler echocardiography Echocardiography 2006 23 4 279 286 16640704