References
- Von Ilberg C, Kiefer J, Tillein J, Pfennigdorff T, Hartmann R, Stiirzebecher E, et al. Electric-acoustic stimulation of the auditory system. ORL J Otorhinolar-yngol Relat Spec 1999; 61: 334–40.
- Kiefer J, Tillein J, Von Ilberg C, Pfennigdorff T, Stürzebecher E, Klinke R, et al. Fundamental aspects and first results of the clinical application of combined electric and acoustic stimulation of the auditory system. In: Kubo T, Takahashi Y, Iwaki T, editors. Cochlear implants-an update. The Hague, The Netherlands: Kugler; 2002. p. 569–76.
- Kiefer J, Gstoettner W, Baumgartner W, Pok SM, Tillein JE, Ye Q, et al. Conservation of low frequency hearing in cochlear implantation. Acta Otolaryngol 2003; 123: 1–10.
- Adunka 0, Kiefer J, Unkelbach MH, Lehnert T, Gstoettner W. Development and evaluation of an improved cochlear implant electrode design for electric and acoustic stimulation. The Laryngoscope 2003; In press.
- Tykocinski M, Cohen L, Pyman BC, Roland T Jr, Treba C, Palamara J, et al. Comparison of electrode position in the human cochlea using various perimodiolar electrode arrays. Am J Otol 2000; 21: 205–11.
- Richter B, Jaekel K, Aschendorff A, Marangos N, Laszig R. Cochlear structures after implantation of a perimodiolar electrode array. Laryngoscope 2001; 111: 837–43.
- Fayad JN, Luxford W, Linthicum FH. The Clarion Electrode Positioner: temporal bone studies. Am J Otol 2000; 21: 226–9.
- Gstoettner WK, Adunka O, Franz P, Hamzavi J, Plenk H, Susani M, et al. Perimodiolar electrodes in cochlear implant surgery. Acta Otolaryngol 2001; 121: 216–9.
- Gstoettner W, Baumgartner W, Franz P, Hamzavi J. Cochlear implant deep insertion surgery. Laryngoscope 1997; 107: 544–6.
- Czerny C, Steiner E, Gstoettner W, Baumgartner W, Imhof H. Postoperative radiographic assessment of the Combi 40 cochlear implant. AJR Am J Roentgenol 1997; 169: 1689–94.
- Marsh MA, Xu J, Blamey PJ, Whitford LA, Xu SA, Silverman JM, et al. Radiologic evaluation of multi-channel intracochlear implant insertion depth. Am J Otol 1993; 14: 386–91.
- Leake PA, Hradek GT, Snyder RL. Chronic electrical stimulation by a cochlear implant promotes survival of spiral ganglion neurons after neonatal deafness. J Comp Neurol 1999; 412: 543–62.
- Fayad J, Linthicum FH, Otto SR, Galey FR, House WF. Cochlear implants: histopathologic findings related to performance in 16 human temporal bones. Ann Otol Rhinol Laryngol 1991; 100: 807–11.
- Miura M, Sando I, Hirsch BE, Orita Y. Analysis of spiral ganglion cell populations in children with normal and pathological ears. Ann Otol Rhinol Laryngol 2002; 111: 1059–65.
- Leake PA, Hradek GT, Snyder RL. Chronic electrical stimulation by a cochlear implant promotes survival of spiral ganglion neurons after neonatal deafness. J Comp Neurol 1999; 412: 543–62.
- Moralee SJ. The effect of inflammation on spiral gang-lion cell density measurements in the cat cochlea. Clin Otolaryngol 2000; 25: 492–4.
- Miller AL, Morris DJ, Pfingst BE. Effects of time after deafening and implantation on guinea pig electrical detection thresholds. Hear Res 2000; 144: 175–86.
- Sekiya T, Shimamura N, Suzuki S, Hatayama T. Methylprednisolone ameliorates cochlear nerve degen-eration following mechanical injury. Hear Res 2001; 151: 125–32.