End-user verification results of two serum separator tubes for clinical chemistry analytes according to CLSI GP34-A and CLSI GP41-A6

ORCID Icon, , , , , , , & show all
Pages 183-192 | Received 06 Dec 2023, Accepted 12 Apr 2024, Published online: 03 May 2024

References

  • Smets EM, Dijkstra-Lagemaat JE, Blankenstein MA. Influence of blood collection in plastic vs. glass evacuated serum-separator tubes on hormone and tumour marker levels. Clin Chem Lab Med. 2004;42(4):435–439. doi: 10.1515/CCLM.2004.076.
  • Hill BM, Laessig RH, Koch DD, et al. Comparison of plastic vs. glass evacuated serum-separator (SST) blood-drawing tubes for common clinical chemistry determinations. Clin Chem. 1992;38(8 Pt 1):1474–1478. doi: 10.1093/clinchem/38.8.1474.
  • Stankovic AK, Parmar G. Assay interferences from blood collection tubes: a cautionary note. Clin Chem. 2006;52(8):1627–1628. doi: 10.1373/clinchem.2006.069997.
  • Bowen RA, Chan Y, Cohen J, et al. Effect of blood collection tubes on total triiodothyronine and other laboratory assays. Clin Chem. 2005;51(2):424–433. doi: 10.1373/clinchem.2004.043349.
  • Bowen RA, Chan Y, Ruddel ME, et al. Immunoassay interference by a commonly used blood collection tube additive, the organosilicone surfactant silwet L-720. Clin Chem. 2005;51(10):1874–1882. doi: 10.1373/clinchem.2005.055400.
  • Bowen RA, Remaley AT. Interferences from blood collection tube components on clinical chemistry assays. Biochem Med (Zagreb). 2014;24(1):31–44. doi: 10.11613/BM.2014.006.
  • Aarsand AK, Fernandez-Calle P, Webster C, et al. The EFLM Biological Variation Database[cited. https://biologicalvariation.eu/. [30/06/2023].
  • CLSI. Collection of diagnostic venous blood specimens. 7th ed. CLSI standard. GP41-A6. Wayne (PA): Clinical and Laboratory Standards Institute; 2017.
  • CLSI. Validation and verification of tubes for venous and capillary blood. Specimen collection; approved guideline. CLSI document GP34-A. Wayne (PA): Clinical and Laboratory Standards Institute; 2010.
  • CLSI. Measurement procedure comparison and bias estimation using patient samples. Approved Guideline—Third Edition. EP09-A3. Wayne (PA): Clinical and Laboratory Standards Institute; 2013.
  • Desirable Specifications for Total Error, Imprecision, and Bias, derived from intra- and inter-individual biologic variation [Internet]. [cited 30/06/2023]. Available from: https://www.westgard.com/biodatabase1.htm.
  • Martin RF. General deming regression for estimating systematic bias and its confidence interval in method-comparison studies. Clin Chem. 2000;46(1):100–104. doi: 10.1093/clinchem/46.1.100.
  • Gawria G, Tillmar L, Landberg E. A comparison of stability of chemical analytes in plasma from the BD vacutainer((R)) barricor tube with mechanical separator versus tubes containing gel separator. J Clin Lab Anal. 2020;34(2):e23060.
  • Cat A, Ucar KT, Nurlu N. Could S-Monovette serum gel tubes be used for clinical chemistry analysis Instead of serum separator tube II advance? Clin Lab. 2022;68(4):1–3. doi: 10.7754/Clin.Lab.2021.210841.
  • Kösem A, Topçuoğlu C, Sezer S, et al. Comparison of some biochemical tests in different blood collection tubes in hemodialysis patients. Turk J Biochem. 2020;45(1):26–36. doi: 10.1515/tjb-2018-0341.
  • Shin S, Oh J, Park HD. Comparison of three blood collection tubes for 35 bBiochemical analytes: the becton dickinson barricor tube, serum separating tube, and plasma separating tube. Ann Lab Med. 2021;41(1):114–119. doi: 10.3343/alm.2021.41.1.114.
  • Raizman JE, Goudreau BL, Füzéry AK, et al. Barricor blood collection tubes are equivalent to PST for a variety of chemistry and immunoassay analytes except for lactate dehydrogenase. Clin Chim Acta. 2019;496:18–24. doi: 10.1016/j.cca.2019.06.013.
  • Chung HJ, Song YK, Hong SK, et al. Implementation of biological variation-based analytical performance specifications in the laboratory: stringent evaluation of ımprovacutor blood collection tubes. PLoS One. 2017;12(12):e0189882. doi: 10.1371/journal.pone.0189882.
  • Kang H, Cho HW, Rim JH, et al. Comparison of blood collection tubes for 29 biochemical analytes in pediatric patients with Central venous catheters. Clin Biochem. 2022;107:73–79. doi: 10.1016/j.clinbiochem.2022.04.017.
  • Schouwers S, Brandt I, Willemse J, et al. Influence of separator gel in sarstedt S-Monovette(R) serum tubes on various therapeutic drugs, hormones, and proteins. Clin Chim Acta. 2012;413(1-2):100–104. doi: 10.1016/j.cca.2011.08.037.
  • Oosterhuis WP, Coskun A, Sandberg S, et al. Performance specifications for sodium should not be based on biological variation. Clin Chim Acta. 2023;540:117221. doi: 10.1016/j.cca.2023.117221.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.