47
Views
8
CrossRef citations to date
0
Altmetric
Original

Simultaneous application of differential servo-oscillometry and volume-clamp plethysmography for continuous non-invasive recording of the finger blood pressure response to a hand postural change

, , , , &
Pages 139-144 | Published online: 09 Jul 2009

References

  • Peñáz J. Photoelectric measurement of blood pressure, volume and flow in the finger. Digest of the 10th International Conference on Medical and Biological Engineering. Dresden. 1973; 104
  • Imholz B. P.M., Langewouters G. J., van Montfrans G. A., Parati G., van Goudoever J., Wesseling K. H., Wieling W., Mancia G. Feasibility of ambulatory, continuous 24-hour finger arterial pressure recording. Hypertension 1993; 21: 65–73
  • Imholz B. P.M., Wieling W., van Montfrans G. A., Wesseling K. H. Fifteen years experience with finger arterial pressure monitoring: assessment and technology. Cardiovascular Research 1998; 38: 605–616
  • Langewouters G. J., Settels J. J., Roelandt R., Wesseling K. H. Why use Finapres or Portapres rather than intraarterial or intermittent non-invasive techniques of blood pressure measurement. Journal of Medical Engineering and Technology 1998; 22: 37–43
  • Silke B., McAuley D. Accuracy and precision of blood pressure determination with the Finapres: an overview using re-sampling statistics. Journal of Human Hypertension 1998; 12: 403–409
  • Imholz B. P.M., Settels J. J., van den Meiracher H., Wesseling K. H., Wieling W. Noninvasive continuous finger blood pressure measurement during orthostatic stress compared to intraarterial pressure. Cardiovascular Research 1990; 24: 214–221
  • Rongen G. A., Bos W. J.W., Lenders J. W.M., van Montfrans G. A., van Lier H. J.J., van Goudoever J., Wesseling K. H., Thien T. Comparison of intrabrachial and finger blood pressure in healthy volunteers. American Journal of Hypertension 1995; 8: 237–248
  • Bos W. J.W., Imholz B. P.M., van Goudoever J., Wesseling K. H., van Montfrans G. A. The reliability of noninvasive continuous finger blood pressure measurement in patients with both hypertension and vascular disease. Journal of Hypertension 1992; 5: 529–535
  • Eckert S., Horstkotte D. Comparison of Portapres non-invasive blood pressure measurement in the finger with intra-aortic pressure measurement during incremental bicycle exercise. Blood Pressure Monitoring 2002; 7: 179–183
  • Schutte A. E., Huisman H. W., van Rooyen J. M., Oosthuizen W., Jerling J. C. Sensitivity of the Finometer device in detecting acute and medium-term changes in cardiovascular function. Blood Pressure Monitoring 2003; 8: 195–201
  • Guelen I., Westerhof B. E., van der Sar G. L., van Montfrans G. A., Kiemenej F., Wesseling K. H., Bos W. J. Finometer, finger pressure measurements with the possibility to reconstruct brachial pressure. Blood Pressure Monitoring 2003; 8: 27–30
  • Parati G., Ongaro G., Bilo G., Glavina F., Castiglioni P., Di Rienzo M., Mancia G. Non-invasive beat-to-beat blood pressure monitoring: new developments. Blood Pressure Monitoring 2003; 8: 31–36
  • Belani K., Ozaki M., Hynson J., Hartman T., Reyford H., Martino J. -M., Poliac M., Miller R. A new non-invasive method to measure blood pressure. Anesthesiology 1999; 91: 686–692
  • Reeben V., Epler M. Non-invasive continuous measurement of mean arterial blood pressure in man. Digest of the 10th International Conference on Medical and Biological Engineering. Dresden. 1973; 107
  • Reeben V., Epler M. Indirect Continuous Measurement of Mean Arterial Pressure. Advances in Cardiovascular Physics, volume 5, Cardiovascular Engineering. Part II: Monitoring, D. N. Ghista. Karger, Basel 1983; 90–118
  • Jagomägi K., Talts J., Raamat R., Länsimies E. Continuous non-invasive measurement of mean blood pressure in fingers by volume-clamp and differential oscillometric method. Clinical Physiology 1996; 16: 551–560
  • Raamat R., Jagomägi K., Talts J. Different responses of Finapres and the oscillometric finger blood pressure monitor during intensive vasomotion. Journal of Medical Engineering and Technology 2000; 24: 95–101
  • Jagomägi K., Raamat R., Talts J. Effect of altering vasoactivity on the measurement of finger blood pressure. Blood Pressure Monitoring 2001; 6: 33–40
  • Raamat R., Jagomägi K., Talts J., Länsimies E., Jurvelin J., Kolari P. Continuous mean arterial pressure measurement in the fingers: the influence of local arm cooling. Medical and Biological Engineering and Computing 2001; 39: 584–589
  • Raamat R., Jagomägi K., Talts J., Toska K., Walløe L. Recording of short-term finger blood pressure changes induced by an arterial occlusive thigh cuff: comparison between the modified oscillometric and Finapres techniques. Physiological Measurement 2001; 22: N13–N18
  • Wesseling K. H., De Wit B., van Der Hoeven G. M.A., van Godoever J., Settels J. J. Physical, calibrating finger vascular physiology for Finapres. Homeostasis 1995; 36: 67–82
  • Bayliss W. M. On the local reactions of the arterial wall to changes of internal pressure. Journal of Physiology 1902; 28: 220–231
  • Jepsen H., Gaehtgens P. Postural vascular response in human skin: passive and active reactions to alteration of transmural pressure. American Journal of Physiology: Heart Circulation Physiology 1993; 265: H949–H958
  • Lopez-Beltran E. A., Blackshear P. L., Finkelstein S. M., Cohn J. N. Non-invasive studies of peripheral vascular compliance using a non-occluding photoplethysmographic method. Medical and Biological Engineering and Computing 1998; 36: 748–753

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.