1,287
Views
24
CrossRef citations to date
0
Altmetric
Review Article

Understanding outcomes and toxicological aspects of second generation metal-on-metal hip implants: a state-of-the-art review

, ORCID Icon, , , , ORCID Icon, , & ORCID Icon show all
Pages 839-887 | Received 31 Mar 2017, Accepted 20 Dec 2018, Published online: 26 Mar 2019

References

  • AAOS (American Academy of Orthopaedic Surgeons). 2011a. Hip resurfacing. Rosemont (IL): OrthoInfo, American Academy of Orthopaedic Surgeons.
  • AAOS (American Academy of Orthopaedic Surgeons). 2011b. Total hip replacement. Rosemont (IL): OrthoInfo, American Academy of Orthopaedic Surgeons.
  • AAOS (American Academy of Orthopaedic Surgeons). 2012. Information statement: current concerns with metal-on-metal hip arthroplasty. Rosemont (IL): American Academy of Orthopaedic Surgeons.
  • AAOS (American Academy of Orthopaedic Surgeons). 2013. Questions and answers about metal-on-metal hip implant. Rosemont (IL): American Academy of Orthopaedic Surgeons; [accessed 2014 January 21]. http://orthoinfo.aaos.org/topic.cfm?topic=A00625.
  • Amstutz HC. 1996. Editorial comment. Clin Orthopaed Related Res. 329:S2–S3.
  • Amstutz HC, Beaule PE, Dorey FJ, Le Duff MJ, Campbell PA, Gruen TA. 2004. Metal-on-metal hybrid surface arthroplasty: two to six-year follow-up study. J Bone Joint Surg. 86:28–39.
  • Amstutz HC, Campbell P, Kossovsky N, Clarke IC. 1992. Mechanism and clinical significance of wear debris-induced osteolysis. Clin Orthopaed Related Res. 276:7–18.
  • Amstutz HC, Campbell P, McKellop H, Schmalzried TP, Gillespie WJ, Howie D, Jacobs J, Medley J, Merritt K. 1996. Metal on metal total hip replacement workshop consensus document. Clin Orthopaed Related Res. 329:S297–S303.
  • Amstutz HC, Grigoris P. 1996. Metal on metal bearings in hip arthroplasty. Clin Orthopaed Related Res. 329: S11–S34.
  • Amstutz HC, Grigoris P, Dorey FJ. 1998. Evolution and future of surface replacement of the hip. J Orthop Sci. 3:169–186.
  • Amstutz HC, Le Duff MJ. 2008. Eleven years of experience with metal-on-metal hybrid hip resurfacing: a review of 1000 conserve plus. J Arthroplasty. 23:36–43.
  • Amstutz HC, Le Duff MJ. 2012. Failure rates of stemmed metal-on-metal hip replacements. Lancet. 380:105. Author reply 106.
  • Amstutz HC, Le Duff MJ. 2012. Hip resurfacing: a 40-year perspective. HSS J. 8:275–282.
  • Amstutz HC, Le Duff MJ. 2015. Hip resurfacing: history, current status, and future. Hip Int. 25:330–338.
  • Amstutz HC, Markolf KL, McNeice GM, Gruen TA. 1976. Loosening of total hip components: cause and prevention. In: Hip Society, editor. The Hip: Proceedings of the Fourth Open Scientific Meeting of the Hip Society, 1976. Saint Louis (MO): Mosby.
  • Amstutz HC, Thomas BJ, Jinnah R, Kim W, Grogan T, Yale C. 1984. Treatment of primary osteoarthritis of the hip. A comparison of total joint and surface replacement arthroplasty. J Bone Joint Surg. 66:228–241.
  • Amstutz HC, Wisk LE, Le Duff MJ. 2011. Sex as a patient selection criterion for metal-on-metal hip resurfacing arthroplasty. J Arthroplasty. 26:198–208.
  • Andersson G. 1972. Hip assessment: a comparison of nine different methods. J Bone Joint Surg Br. 54:621–625.
  • AOANJRR (Australian Orthopaedic Association. National Joint Replacement Registry). 2007. Annual Report 2007. Sydney: Australian Orthopaedic Association, National Joint Replacement Registry.
  • AOANJRR (Australian Orthopaedic Association. National Joint Replacement Registry). 2008. Annual Report 2008. Sydney: Australian Orthopaedic Association, National Joint Replacement Registry.
  • AOANJRR (Australian Orthopaedic Association. National Joint Replacement Registry). 2009. Annual Report 2009. Hip and Knee Arthroplasty: September 1999 to December 2008. Sydney: Australian Orthopaedic Association, National Joint Replacement Registry.
  • Apel W, Stark D, Stark A, O’Hagan S, Ling J. 2013. Cobalt-chromium toxic retinopathy case study. Doc Ophthalmol. 126:69–78.
  • Aroukatos P, Repanti M, Bravou V, Repantis T, Korovessis P. 2010. Immunologic adverse reaction associated with low-carbide metal-on-metal bearings in total hip arthroplasty. Clin Orthop Relat Res. 468:2135–2142.
  • Atkinson JR, Dowson D, Isaac JH, Wroblewski BM. 1985. Laboratory wear tests and clinical observations of the penetration of femoral heads into acetabular cups in total replacement hip joints. Wear. 104:225–244.
  • ATSDR (Agency for Toxic Substances and Disease Registry). 2004. Toxicological Profile for Cobalt. Atlanta (GA): U.S. Department of Health and Human Services, Public Health Service.
  • ATSDR (Agency for Toxic Substances and Disease Registry). 2012. Toxicological Profile for Chromium. Atlanta (GA): U.S. Department of Health and Human Services, Public Health Service, Agency for Toxic Substances and Disease Registry.
  • August AC, Aldam CH, Pynsent PB. 1986. The McKee–Farrar hip arthroplasty. A long-term study. J Bone Joint Surg Br. 68:520–527.
  • Back DL, Dalziel R, Young D, Shimmin A. 2005. Early results of primary Birmingham hip resurfacings. An independent prospective study of the first 230 hips. J Bone Joint Surg. 87:324–329.
  • Bayley N, Khan H, Grosso P, Hupel T, Stevens D, Snider M, Schemitsch E, Kuzyk P. 2015. What are the predictors and prevalence of pseudotumor and elevated metal ions after large-diameter metal-on-metal THA? Clin Orthopaed Related Res. 473:477–484.
  • Beaule PE, Kim PR, Hamdi A, Fazekas A. 2011. A prospective metal ion study of large-head metal-on-metal bearing: a matched-pair analysis of hip resurfacing versus total hip replacement. Orthopedic Clin North Am. 42:251–257. ix.
  • Beaule PE, Le Duff M, Campbell P, Dorey FJ, Park SH, Amstutz HC. 2004. Metal-on-metal surface arthroplasty with a cemented femoral component: a 7-10 year follow-up study. J Arthroplasty. 19:17–22.
  • Beckenbaugh RD, Ilstrup DM. 1978. Total hip arthroplasty. J Bone Joint Surg Am. 60:306–313.
  • Behl B, Papageorgiou I, Brown C, Hall R, Tipper JL, Fisher J, Ingham E. 2013. Biological effects of cobalt-chromium nanoparticles and ions on dural fibroblasts and dural epithelial cells. Biomaterials. 34:3547–3558.
  • Berber R, Skinner J, Board T, Kendoff D, Eskelinen A, Kwon YM, Padgett DE, Hart A. 2016a. International metal-on-metal multidisciplinary teams: do we manage patients with metal-on-metal hip arthroplasty. In the same way? An Analysis from the International Specialist Centre Collaboration on MOM Hips (ISCCoMH). Bone Joint J. 98-B:179–186.
  • Berber R, Skinner JA, Hart AJ. 2016. Management of metal-on-metal hip implant patients: who, when and how to revise? World J Orthop. 7:272–279.
  • Berquist TH, Bender CE, Maus TP, Ward EM, Rand JA. 1987. Pseudobursae: a useful finding in patients with painful hip arthroplasty. Ajr Am J Roentgenol. 148:103–106.
  • Berton C, Girard J, Krantz N, Migaud H. 2010. The Durom large diameter head acetabular component: early results with a large-diameter metal-on-metal bearing. J Bone Joint Surg. 92:202–208.
  • Bhabra G, Sood A, Fisher B, Cartwright L, Saunders M, Evans WH, Surprenant A, Lopez-Castejon G, Mann S, Davis SA, et al. 2009. Nanoparticles can cause DNA damage across a cellular barrier. Nature Nanotech. 4:876–883.
  • Billi F, Benya P, Kavanaugh A, Adams J, McKellop H, Ebramzadeh E. 2012. The John Charnley Award: an accurate and extremely sensitive method to separate, display, and characterize wear debris: part 2: metal and ceramic particles. Clin Orthop Relat Res. 470:339–350.
  • Billi F, Campbell P. 2010. Nanotoxicology of metal wear particles in total joint arthroplasty: a review of current concepts. J Appl Biomater Biomechanics. 8:1–6.
  • Bishop N, Witt F, Pourzal R, Fischer A, Rutschi M, Michel M, Morlock M. 2013. Wear patterns of taper connections in retrieved large diameter metal-on-metal bearings. J Orthop Res. 31:1116–1122.
  • Black J, Levine B, Jacobs J. 2007. Chapter 7. Biomaterials overview. In: Callaghan JJ, Rosenberg AG, Rubash HE, editors. The adult hip. 2nd ed. Vol. 1. Philadelphia (PA): Lippincott Williams & Wilkins.
  • Bobyn JD. 1991. Polyethylene wear debris. Can J Surg. 34:530–531.
  • Bolognesi MP, Ledford CK. 2015. Metal-on-metal total hip arthroplasty: patient evaluation and treatment. J Am Acad Orthopaed Surg. 23:724–731.
  • Bosker BH, Ettema HB, Boomsma MF, Kollen BJ, Maas M, Verheyen CC. 2012. High incidence of pseudotumour formation after large-diameter metal-on-metal total hip replacement: a prospective cohort study. J Bone Joint Surg. 94:755–761.
  • Brewster DH, Stockton DL, Reekie A, Ashcroft GP, Howie CR, Porter DE, Black RJ. 2013. Risk of cancer following primary total hip replacement or primary resurfacing arthroplasty of the hip: a retrospective cohort study in Scotland. Br J Cancer. 108:1883–1890.
  • Brodner W, Bitzan P, Meisinger V, Kaider A, Gottsauner-Wolf F, Kotz R. 2003. Serum cobalt levels after metal-on-metal total hip arthroplasty. J Bone Joint Surg. 85:2168–2173.
  • Brown SR, Davies WA, DeHeer DH, Swanson AB. 2002. Long-term survival of McKee-Farrar total hip prostheses. Clin Orthopaed Related Res. 402:157–163.
  • Brown C, Fisher J, Ingham E. 2006. Biological effects of clinically relevant wear particles from metal-on-metal hip prostheses. Proc Inst Mech Eng H. 220:355–369.
  • Brown C, Lacharme-Lora L, Mukonoweshuro B, Sood A, Newson RB, Fisher J, Case CP, Ingham E. 2013. Consequences of exposure to peri-articular injections of micro- and nano-particulate cobalt-chromium alloy. Biomaterials. 34:8564–8580.
  • Brown GC, Lockshin MD, Salvati EA, Bullough PG. 1977. Sensitivity to metal as a possible cause of sterile loosening after cobalt-chromium total hip-replacement arthroplasty. J Bone Joint Surg. 59:164–168.
  • Bullough PG. 1973. Tissue reaction to wear debris generated from total hip replacements. In: Hip Society, editor. The Hip, Proceedings of the First Open Scientific Meeting of the Hip Society. St. Louis (MO): Mosby.
  • Burroughs BR, Hallstrom B, Golladay GJ, Hoeffel D, Harris WH. 2005. Range of motion and stability in total hip arthroplasty with 28-, 32-, 38-, and 44-mm femoral head sizes. J Arthroplasty. 20:11–19.
  • Callaghan JJ, Dysart SH, Savory CF, Hopkinson WJ. 1990. Assessing the results of hip replacement. A comparison of five different rating systems. J Bone Joint Surg. 72:1008–1009.
  • Callaghan JJ, O'Rourke MR, Johnston RC. 2007. Revision of the femoral component: cement. In Callaghan JJ, Rosenberg AG, Rubash HE, editors. The Adult Hip. 2nd ed. Vol. 2. Philadelphia (PA): Lippincott Williams & Wilkins.
  • Campbell P, Ebramzadeh E, Nelson S, Takamura K, De Smet K, Amstutz HC. 2010. Histological features of pseudotumor-like tissues from metal-on-metal hips. Clin Orthop Relat Res. 468:2321–2327.
  • Carlsson AS, Magnusson B, Moller H. 1980. Metal sensitivity in patients with metal-to-plastic total hip arthroplasties. Acta Orthop Scand. 51:57–62.
  • Case CP, Ellis L, Turner JC, Fairman B. 2001. Development of a routine method for the determination of trace metals in whole blood by magnetic sector inductively coupled plasma mass spectrometry with particular relevance to patients with total hip and knee arthroplasty. Clin Chem. 47:275–280.
  • Castellanos MV, Hernandez JM, Ramos L, Belen Gonzalez M, Gutierrez NC, Leone PE, Lumbreras E, Robledo C, Garcia Hernandez JL. 2004. Chromosomal abnormalities are related to location and grade of osteoarthritis. Osteoarthritis Cartilage. 12:982–985.
  • Catelas I, Bobyn JD, Medley JB, Krygier JJ, Zukor DJ, Huk OL. 2003. Size, shape, and composition of wear particles from metal-metal hip simulator testing: effects of alloy and number of loading cycles. J Biomed Mater Res A. 67:312–327.
  • Catelas I, Campbell PA, Bobyn JD, Medley JB, Huk OL. 2006. Wear particles from metal-on-metal total hip replacements: effects of implant design and implantation time. Proc Inst Mech Eng H. 220:195–208.
  • Catelas I, Medley JB, Campbell PA, Huk OL, Bobyn JD. 2004. Comparison of in vitro with in vivo characteristics of wear particles from metal-metal hip implants. J Biomed Mater Res. 70:167–178.
  • Chalmers BP, Perry KI, Taunton MJ, Mabry TM, Abdel MP. 2016. Diagnosis of adverse local tissue reactions following metal-on-metal hip arthroplasty. Curr Rev Musculoskelet Med. 9:67–74.
  • Chang EY, McAnally JL, Van Horne JR, Van Horne JG, Wolfson T, Gamst A, Chung CB. 2013. Relationship of plasma metal ions and clinical and imaging findings in patients with ASR XL metal-on-metal total hip replacements. J Bone Joint Surg. 95:2015–2020.
  • Charnley J. 1961. Arthroplasty of the hip. A new operation. Lancet. 1:1129–1132.
  • Charnley J. 1966. Paper 2: factors in the design of an artificial hip joint. Proc Inst Mech Eng Conf Proc. 181:104–111.
  • Charnley J. 1970. Acrylic cement in orthopaedic surgery. Baltimore (MD): Williams and Wilkins.
  • Charnley J. 1972. The long-term results of low-friction arthroplasty of the hip performed as a primary intervention. J Bone Joint Surg Br. 54:61–76.
  • Charnley J. 1975. Fracture of femoral prostheses in total hip replacement. A clinical study. Clin Orthopaed Related Res. 111:105–120.
  • Charnley J, Cupic Z. 1973. The nine and ten year results of the low-friction arthroplasty of the hip. Clin Orthopaed Related Res. 95:9–25.
  • Charosky CB, Bullough PG, Wilson PD Jr. 1973. Total hip replacement failures. A histological evaluation. J Bone Joint Surg Am. 55:49–58.
  • Christian WV, Oliver LD, Paustenbach DJ, Kreider ML, Finley BL. 2014. Toxicology-based cancer causation analysis of CoCr-containing hip implants: a quantitative assessment of genotoxicity and tumorigenicity studies. J Appl Toxicol. 34:939–967.
  • Clarke MT, Lee PT, Arora A, Villar RN. 2003. Levels of metal ions after small- and large-diameter metal-on-metal hip arthroplasty. J Bone Joint Surg. 85:913–917.
  • Clohisy JC, Harris WH. 1999. The Harris-Galante uncemented femoral component in primary total hip replacement at 10 years. J Arthroplasty. 14:915–917.
  • Cobb A, Schmalzreid T. 2006. The clinical significance of metal ion release from cobalt-chromium metal-on-metal hip joint arthroplasty. Proc Inst Mech Eng H. 220:385–398.
  • Cozzolino F, Mariconda M, Costa L, Scognamiglio D, Cozzolino A, Marino D, Milano C. 2002. A comparative study on medium-term results of cementless acetabular components with metal-on-metal and metal-on-polyethylene articulations. J Orthopaed Traumatol. 2:129–133.
  • Cramers M, Lucht U. 1977. Metal sensitivity in patients treated for tibial fractures with plates of stainless steel. Acta Orthop Scand. 48:245–249.
  • Cuckler JM. 2005. The rationale for metal-on-metal total hip arthroplasty. Clin Orthop Relat Res. 441:132–136.
  • Cuckler JM, Moore KD, Lombardi AV Jr, McPherson E, Emerson R. 2004. Large versus small femoral heads in metal-on-metal total hip arthroplasty. J Arthroplasty. 19:41–44.
  • Dandy DJ, Theodorou BC. 1975. The management of local complications of total hip replacement by the McKee-Farrar technique. J Bone Joint Surg. 57:30–35.
  • Daniel J, Holland J, Quigley L, Sprague S, Bhandari M. 2012. Pseudotumors associated with total hip arthroplasty. J Bone Joint Surg. 94:86–93.
  • Daniel J, Pradhan C, Ziaee H, Pynsent PB, McMinn DJ. 2014. Results of Birmingham hip resurfacing at 12 to 15 years: a single-surgeon series. Bone Joint J. 96-B:1298–1306.
  • Dastane M, Wan Z, Deshmane P, Long WT, Dorr LD. 2011. Primary hip arthroplasty with 28-mm Metasul articulation. J Arthroplasty. 26:662–664.
  • Davies AP, Sood A, Lewis AC, Newson R, Learmonth ID, Case CP. 2005. Metal-specific differences in levels of DNA damage caused by synovial fluid recovered at revision arthroplasty. J Bone Joint Surg. 87-B:1439–1444.
  • Davies AP, Willert HG, Campbell PA, Learmonth ID, Case CP. 2005. An unusual lymphocytic perivascular infiltration in tissues around contemporary metal-on-metal joint replacements. J Bone Joint Surg. 87:18–27.
  • Davis J. 2014 Oct 23. BREAKING: Jury Clears J&J in hip implant bellwether trial. Law360 (New York).
  • De Haan R, Campbell PA, Su EP, De Smet KA. 2008a. Revision of metal-on-metal resurfacing arthroplasty of the hip: the influence of malpositioning of the components. J Bone Joint Surg. 90:1158–1163.
  • De Haan R, Pattyn C, Gill HS, Murray DW, Campbell PA, De Smet K. 2008b. Correlation between inclination of the acetabular component and metal ion levels in metal-on-metal hip resurfacing replacement. J Bone Joint Surg. 90:1291–1297.
  • De Smet KA. 2005. Belgium experience with metal-on-metal surface arthroplasty. Orthoped Clin N Am. 36:203–213.
  • De Smet K, Calistri A, De Haan R, Campbell PA, Ebramzadeh E, Pattyn C, Gill HS. 2008. Metal ion measurement as a diagnostic tool to identify problems with metal-on-metal hip resurfacing. J Bone Joint Surg. 90:202–208.
  • DeFrancesco CJ, Kamath AF. 2015. Abductor muscle necrosis due to iliopsoas bursal mass after total hip arthroplasty. J Clin Orthop Trauma. 6:288–292.
  • Delaunay C, Petit I, Learmonth ID, Oger P, Vendittoli PA. 2010. Metal-on-metal bearings total hip arthroplasty: the cobalt and chromium ions release concern. Orthopaed Traumatol: Surg Res. 96:894–904.
  • Delaunay CP, Putman S, Puliero B, Begin M, Migaud H, Bonnomet F. 2016. Cementless total hip arthroplasty with metasul bearings provides good results in active young patients: a concise followup. Clin Orthop Relat Res. 474:2126–2133.
  • Depuy Orthopaedics Inc. 2010. Urgent field safety notice. DePuy ASR Articular Surface Replacement and ASR XL Monoblock Metal-on-Metal System. Type of action: new revision rate data/information regarding the use of the device. FSCA Identifier: DINT 12725. Leeds: DePuy International Ltd.
  • DePuy Orthopaedics Inc. 2012. DePuy ASR hip recall resource packet: updated January 31, 2012. Warsaw (IN): DePuy Orthopaedics.
  • Deutman R, Mulder TJ, Brian R, Nater JP. 1977. Metal sensitivity before and after total hip arthroplasty. J Bone Joint Surg. 59:862–865. American
  • DiGioia AM 3rd, Picard F, Jaramaz B, Moody J, Plakseychuk A. 2002. Computer-assisted orthopaedic surgery for the hip. In Sinha RK, editor, Hip replacement: current trends and controversies. New York: Marcel Dekker.
  • Dobbs HS. 1980. Survivorship of total hip replacements. J Bone Joint Surg. 62:168–173.
  • Dobbs HS, Scales JT. 1983. Behavior of commercially pure titanium and Ti-318 (Ti-6Al-4V) in orthopedic implants. In: Luckey HA, Kubli F. Titanium alloys in surgical implants. ASTM STP 796. West Conshohocken (PA): American Society for Testing Materials.
  • Donaldson K, Stone V, Tran CL, Kreyling W, Borm PJ. 2004. Nanotoxicology. Occup Environ Med. 61:727–728.
  • Doorn PF, Campbell PA, Amstutz HC. 1996. Metal versus polyethylene wear particles in total hip replacements. A review. Clin Orthopaed Related Res. 329:S206–S216.
  • Doorn PF, Campbell PA, Worrall J, Benya PD, McKellop HA, Amstutz HC. 1998. Metal wear particle characterization from metal on metal total hip replacements: transmission electron microscopy study of periprosthetic tissues and isolated particles. J Biomed Mater Res. 42:103–111.
  • Doorn PF, Mirra JM, Campbell PA, Amstutz HC. 1996. Tissue reaction to metal on metal total hip prostheses. Clin Orthopaed Related Res. 329:S187–S205.
  • Dorr LD, Hilton KR, Wan Z, Markovich GD, Bloebaum R. 1996. Modern metal on metal articulation for total hip replacements. Clin Orthopaed Related Res. 333:108–117.
  • Dorr LD, Long WT, Sirianni L, Campana M, Wan Z. 2004. The argument for the use of Metasul as an articulation surface in total hip replacement. Clin Orthopaed Related Res. 429:80–85.
  • Dorr LD, Wan Z, Longjohn DB, Dubois B, Murken R. 2000. Total hip arthroplasty with use of the Metasul metal-on-metal articulation. Four to seven-year results. J Bone Joint Surg. 82:789–798.
  • Dowson D, Hardaker C, Flett M, Isaac GH. 2004. A hip joint simulator study of the performance of metal-on-metal joints; Part II: design. J Arthroplasty. 19:124–130.
  • Duff-Barclay I, Scales JT, Wilson JN. 1966. Biomechanics. The development of the Stanmore total hip replacement. Proc R Soc Med. 59:948–951.
  • Duffin R, Tran L, Brown D, Stone V, Donaldson K. 2007. Proinflammogenic effects of low-toxicity and metal nanoparticles in vivo and in vitro: highlighting the role of particle surface area and surface reactivity. Inhal Toxicol. 19:849–856.
  • Eftekhar N. 1971. Charnley "low friction torque" arthroplasty. A study of long-term results. Clin Orthopaed Related Res. 81:93–104.
  • Eicher P. 1959. Use of prosthesis in the fresh intracapsular fracture of the hip. In: Reynolds FC, editor. Instructional course lectures. Vol. 16. St. Louis (MO): American Academy of Orthopaedic Surgeons.
  • Emery D, Griffiths W. 1997. Ileopectineal bursitis: orthopaedic cause for a lump in the groin. J R Soc Med. 90:158–159.
  • Engh CA Sr, Bugbee WD, Culpepper WJ 2nd. 1995. Cementless acetabular components: optimums and outcomes. Orthopedics. 18:813–815.
  • Enzler M, Drobny T, Franzeck U, Inderbitzi R, Leu A. 2000. Inguinal mass as a late complication of hip arthroplasty. Differential diagnosis and treatment from a vascular surgical perspective. Vasa. 29:288–291.
  • Fabi D, Levine B, Paprosky W, Della Valle C, Sporer S, Klein G, Levine H, Hartzband M. 2012. Metal-on-metal total hip arthroplasty: causes and high incidence of early failure. Orthopedics. 35:e1009–e1016.
  • Fang CS, Harvie P, Gibbons CL, Whitwell D, Athanasou NA, Ostlere S. 2008. The imaging spectrum of peri-articular inflammatory masses following metal-on-metal hip resurfacing. Skeletal Radiol. 37:715–722.
  • Fehring TK, Fehring K, Odum SM. 2015. Metal artifact reduction sequence MRI abnormalities occur in metal-on-polyethylene hips. Clin Orthop Relat Res. 473:574–580.
  • Fehring TK, Odum S, Sproul R, Weathersbee J. 2014. High frequency of adverse local tissue reactions in asymptomatic patients with metal-on-metal THA. Clin Orthop Relat Res. 472:517–522.
  • Ferrata P, Carta S, Fortina M, Scipio D, Riva A, Di Giacinto S. 2011. Painful hip arthroplasty: definition. Clin Cases Miner Bone Metab. 8:19–22.
  • Field E. 2014 Nov 3. Stryker to pay $1B to settle hip implant MDL claims. Law360 (New York).
  • Finley BL, Monnot AD, Gaffney SH, Paustenbach DJ. 2012. Dose–response relationships for blood cobalt concentrations and health effects: a review of the literature and application of a biokinetic model. J Toxicol Environ Health Part B. 15:493–523.
  • Finley B, Scott PK, Glynn ME, Paustenbach D, Donovan E, Thuett KA. 2017. Chromium speciation in the blood of metal-on-metal hip implant patients. Toxicol Environ Chem. 99:48–64.
  • Finley BL, Unice KM, Kerger BD, Otani JM, Paustenbach DJ, Galbraith DA, Tvermoes BE. 2013. 31-day study of cobalt (II) chloride ingestion in humans: pharmacokinetics and clinical effects. J Toxicol Environ Health. Part A. 76:1210–1224.
  • Firkins PJ, Tipper JL, Saadatzadeh MR, Ingham E, Stone MH, Farrar R, Fisher J. 2001. Quantitative analysis of wear and wear debris from metal-on-metal hip prostheses tested in a physiological hip joint simulator. Biomed Mater Eng. 11:143–157.
  • Foussereau J, Laugier P. 1966. Allergic eczemas from metallic foreign bodies. Transact St. John's Hospital Dermatol Soc. 52:220–225.
  • Fregert S, Rorsman H. 1966. Allergic reactions to trivalent chromium compounds. Arch Dermatol. 93:711–713.
  • Friedman DW, Orland PJ, Greco RS. 1994. Biomaterials: an historical perspective. In: Greco RS, editor. Implantation biology: the host response and biomedical devices. Boca Raton (FL): CRC Press.
  • Frigerio E, Pigatto PD, Guzzi G, Altomare G. 2011. Metal sensitivity in patients with orthopaedic implants: a prospective study. Contact Dermatitis. 64:273–279.
  • Galante J, Rostoker W. 1972. Corrosion-related failures in metallic implants: an experimental study. Clin Orthopaed Related Res. 86:237–244.
  • Gebhard JS, Kabo JM, Amstutz HC. 1990. Socket wear and frictional torque in "long term" conventional hip implants. In: Orthopaedic Research Society, editor. Transactions of the 36th Annual Meeting of the Orthopaedic Research Society; Feb 5–8, 1990; New Orleans, LA. Vol. 15. Section 1. Chicago (IL): Adept Printing.
  • Germain MA, Hatton A, Williams S, Matthews JB, Stone MH, Fisher J, Ingham E. 2003. Comparison of the cytotoxicity of clinically relevant cobalt–chromium and alumina ceramic wear particles in vitro. Biomaterials. 24:469–479.
  • Gilbert JL. 2007. Metals. In: Callaghan JJ, Rosenberg AG, Rubash HE, editors. The adult hip. 2nd ed. Vol. 1. Philadelphia (PA): Lippincott Williams & Wilkins.
  • Gill HS, Grammatopoulos G, Adshead S, Tsialogiannis E, Tsiridis E. 2012. Molecular and immune toxicity of CoCr nanoparticles in MoM hip arthroplasty. Trends Mol Med. 18:145–155.
  • Girard J, Lavigne M, Vendittoli PA, Roy AG. 2006. Biomechanical reconstruction of the hip: a randomised study comparing total hip resurfacing and total hip arthroplasty. J Bone Joint Surg. 88:721–726.
  • Goldacre MJ, Wotton CJ, Seagroatt V, Yeates D. 2005. Cancer following hip and knee arthroplasty: record linkage study. Br J Cancer. 92:1298–1301.
  • Goode AE, Perkins JM, Sandison A, Karunakaran C, Cheng H, Wall D, Skinner J, Hart AJ, Porter AE, McComb DW, Ryan MP. 2012. Chemical speciation of nanoparticles surrounding metal-on-metal hips. Chem Commun. 48:8335–8337.
  • Graves SE, Rothwell A, Tucker K, Jacobs JJ, Sedrakyan A. 2011. A multinational assessment of metal-on-metal bearings in hip replacement. J Bone Joint Surg. 93:43–47.
  • Griffin WL. 2014. Metal ion levels: how can they help us? J Arthroplasty. 29:659–660.
  • Griffin WL, Fehring TK, Kudrna JC, Schmidt RH, Christie MJ, Odum SM, Dennos AC. 2012. Are metal ion levels a useful trigger for surgical intervention? J Arthroplasty. 27:32–36.
  • Griffin WL, Nanson CJ, Springer BD, Davies MA, Fehring TK. 2010. Reduced articular surface of one-piece cups: a cause of runaway wear and early failure. Clin Orthop Relat Res. 468:2328–2332.
  • Griffiths HJ, Burke J, Bonfiglio TA. 1987. Granulomatous pseudotumors in total joint replacement. Skeletal Radiol. 16:146–152.
  • Grigoris P, Roberts P, Panousis K, Jin Z. 2006. Hip resurfacing arthroplasty: the evolution of contemporary designs. Proc Inst Mech Eng H. 220:95–105.
  • Gruber FW, Bock A, Trattnig S, Lintner F, Ritschl P. 2007. Cystic lesion of the groin due to metallosis: a rare long-term complication of metal-on-metal total hip arthroplasty. J Arthroplasty. 22:923–927.
  • Haboush EJ. 1953. A new operation for arthroplasty of the hip based on biomechanics, photoelasticity, fast-setting dental acrylic, and other considerations. Bull Hospital Joint Dis. 14:242–277.
  • Hallab N, Merritt K, Jacobs JJ. 2001. Metal sensitivity in patients with orthopaedic implants. J Bone Joint Surg. 83:428–436.
  • Hallab NJ, Mikecz K, Vermes C, Skipor A, Jacobs JJ. 2001. Differential lymphocyte reactivity to serum-derived metal-protein complexes produced from cobalt-based and titanium-based implant alloy degradation. J Biomed Mater Res. 56:427–436.
  • Harris WH. 1969. Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am. 51:737–755.
  • Harris WH. 1993. Keynote address: clinical considerations. In: Morrey BF, editor. Biological, material, and mechanical considerations of joint replacement. Bristol-Myers Squibb/Zimmer Orthopaedic Symposium Series. New York: Raven Press.
  • Harris WH. 1995. The problem is osteolysis. Clin Orthopaed Related Res. 311:46–53.
  • Harris WH, Schiller AL, Scholler JM, Freiberg RA, Scott R. 1976. Extensive localized bone resorption in the femur following total hip replacement. J Bone Joint Surg Am. 58:612–618.
  • Hart AJ, Buddhdev P, Winship P, Faria N, Powell JJ, Skinner JA. 2008. Cup inclination angle of greater than 50 degrees increases whole blood concentrations of cobalt and chromium ions after metal-on-metal hip resurfacing. Hip Int. 18:212–219.
  • Hart AJ, Hester T, Sinclair K, Powell JJ, Goodship AE, Pele L, Fersht NL, Skinner J. 2006. The association between metal ions from hip resurfacing and reduced T-cell counts. J Bone Joint Surg. 88:449–454.
  • Hart AJ, Ilo K, Underwood R, Cann P, Henckel J, Lewis A, Cobb J, Skinner J. 2011a. The relationship between the angle of version and rate of wear of retrieved metal-on-metal resurfacings: a prospective, CT-based study. J Bone Joint Surg. 93:315–320.
  • Hartmann A, Hannemann F, Lutzner J, Seidler A, Drexler H, Gunther KP, Schmitt J. 2013. Metal ion concentrations in body fluids after implantation of hip replacements with metal-on-metal bearing – systematic review of clinical and epidemiological studies. PLoS ONE. 8:e70359–e70384.
  • Hart AJ, Muirhead-Allwood S, Porter M, Matthies A, Ilo K, Maggiore P, Underwood R, Cann P, Cobb J, Skinner JA. 2013. Which factors determine the wear rate of large-diameter metal-on-metal hip replacements?: multivariate analysis of two hundred and seventy-six components. J Bone Joint Surg Am. 95:678–685.
  • Hart AJ, Quinn PD, Sampson B, Sandison A, Atkinson KD, Skinner JA, Powell JJ, Mosselmans JFW. 2010. The chemical form of metallic debris in tissues surrounding metal-on-metal hips with unexplained failure. Acta Biomaterialia. 6:4439–4446.
  • Hart AJ, Sabah SA, Bandi AS, Maggiore P, Tarassoli P, Sampson B, J AS. 2011b. Sensitivity and specificity of blood cobalt and chromium metal ions for predicting failure of metal-on-metal hip replacement. J Bone Joint Surg. 93:1308–1313.
  • Hart AJ, Sabah SA, Henckel J, Lloyd G, Skinner JA. 2015. Lessons learnt from metal-on-metal hip arthroplasties will lead to safer innovation for all medical devices. Hip Int. 25:347–354.
  • Hart AJ, Sabah SA, Sampson B, Skinner JA, Powell JJ, Palla L, Pajamaki KJJ, Puolakka T, Reito A, Eskelinen A. 2014. Surveillance of patients with metal-on-metal hip resurfacing and total hip prostheses: a prospective cohort study to investigate the relationship between blood metal ion levels and implant failure. J Bone Joint Surg. 96:1091–1099.
  • Hart AJ, Satchithananda K, Liddle AD, Sabah SA, McRobbie D, Henckel J, Cobb JP, Skinner JA, Mitchell AW. 2012. Pseudotumors in association with well-functioning metal-on-metal hip prostheses: a case-control study using three-dimensional computed tomography and magnetic resonance imaging. J Bone Joint Surg. 94:317–325.
  • Hart AJ, Skinner JA, Winship P, Faria N, Kulinskaya E, Webster D, Muirhead-Allwood S, Aldam CH, Anwar H, Powell JJ. 2009. Circulating levels of cobalt and chromium from metal-on-metal hip replacement are associated with CD8+ T-cell lymphopenia. J Bone Joint Surg. 91:835–842.
  • Hauptfleisch J, Pandit H, Grammatopoulos G, Gill HS, Murray DW, Ostlere S. 2012. A MRI classification of periprosthetic soft tissue masses (pseudotumours) associated with metal-on-metal resurfacing hip arthroplasty. Skeletal Radiol. 41:149–155.
  • Health Canada. 2012. Metal-on-metal hip implants – information for orthopaedic surgeons regarding patient management following surgery – for health professionals; [accessed 2015 Dec 3]. http://www.healthycanadians.gc.ca/recall-alert-rappel-avis/hc-sc/2012/15835a-eng.php.
  • Heaton KT, Dorr LD. 2001. Total hip arthroplasty with metasul articulation. Operative Techn Orthopaed. 11:244–252.
  • Hettfleisch J, Wissenbach R. 1994. Forty-year survival of a Judet hip prosthesis: a case report. J Bone Joint Surg Br. 76:671–672.
  • Higuchi F, Inoue A, Semlitsch M. 1997. Metal-on-metal CoCrMo McKee–Farrar total hip arthroplasty: characteristics from a long-term follow-up study. Arch Orthop Trauma Surg. 116:121–124.
  • Holzwarth U, Cotogno G. 2012. Total hip arthroplasty: state of the art, challenges and prospects. Luxembourg: Publications Office.
  • Huber M, Reinisch G, Trettenhahn G, Zweymuller K, Lintner F. 2009. Presence of corrosion products and hypersensitivity-associated reactions in periprosthetic tissue after aseptic loosening of total hip replacements with metal bearing surfaces. Acta Biomater. 5:172–180.
  • Hur CI, Yoon TR, Cho SG, Song EK, Seon JK. 2008. Serum ion level after metal-on-metal THA in patients with renal failure. Clin Orthop Relat Res. 466:696–699.
  • Hwang KT, Kim YH, Kim YS, Choi IY. 2011. Cementless total hip arthroplasty with a metal-on-metal bearing in patients younger than 50 years. J Arthroplasty. 26:1481–1487.
  • Hwang KT, Kim YH, Kim YS, Choi IY. 2013. Is second generation metal-on-metal primary total hip arthroplasty with a 28 mm head a worthy option?: a 12- to 18-year follow-up study. J Arthroplasty. 28:1828–1833.
  • Ikeda T, Takahashi K, Kabata T, Sakagoshi D, Tomita K, Yamada M. 2010. Polyneuropathy caused by cobalt–chromium metallosis after total hip replacement. Muscle Nerve. 42:140–143.
  • Innmann MM, Gotterbarm T, Kretzer JP, Merle C, Ewerbeck V, Weiss S, Aldinger PR, Streit MR. 2014. Minimum ten-year results of a 28-mm metal-on-metal bearing in cementless total hip arthroplasty in patients fifty years of age and younger. Int Orthopaed (Sicot). 38:929–934.
  • Isaac GH, Atkinson JR, Dowson D, Wroblewski BM. 1986. The role of cement in the long term performance and premature failure of Charnley low friction arthroplasties. Eng Med. 15:19–22.
  • Isaac GH, Thompson J, Williams S, Fisher J. 2006. Metal-on-metal bearings surfaces: materials, manufacture, design, optimization, and alternatives. Proc Inst Mech Eng H. 220:119–133.
  • Jacobs M, Gorab R, Mattingly D, Trick L, Southworth C. 2004. Three- to six-year results with the Ultima metal-on-metal hip articulation for primary total hip arthroplasty. J Arthroplasty. 19:48–53.
  • Jacobs JJ, Skipor AK, Doorn PF, Campbell P, Schmalzried TP, Black J, Amstutz HC. 1996. Cobalt and chromium concentrations in patients with metal on metal total hip replacements. Clin Orthopaed Related Res.329:S256–S263.
  • Jacobsson S-A, Djerf K, Wahlström O. 1996. Twenty-year results of McKee–Farrar versus Charnley prosthesis. Clin Orthopaed Related Res. 329:S60–S68.
  • Jacobs JJ, Urban RM, Hallab NJ, Skipor AK, Fischer A, Wimmer MA. 2009. Metal-on-metal bearing surfaces. J Am Acad Orthopaed Surg. 17:69–76.
  • Jantsch S, Schwegerl W, Zenz P, Semlitsch M, Fertschak W. 1991. Long-term results after implantation of McKee–Farrar total hip prostheses. Arch Orthop Trauma Surg. 110:230–237.
  • Jennings JM, Dennis DA, Yang CC. 2016. Corrosion of the head-neck junction after total hip arthroplasty. J Am Acad Orthop Surg. 24:349–356.
  • Johanson PE, Fenstad AM, Furnes O, Garellick G, Havelin LI, Overgaard S, Pedersen AB, Karrholm J. 2010. Inferior outcome after hip resurfacing arthroplasty than after conventional arthroplasty. Evidence from the Nordic Arthroplasty Register Association (NARA) database, 1995 to 2007. Acta Orthopaed. 81:535–541.
  • Johnston RC, Fitzgerald RH Jr, Harris WH, Poss R, Muller ME, Sledge CB. 1990. Clinical and radiographic evaluation of total hip replacement. A standard system of terminology for reporting results. J Bone Joint Surg Am. 72:161–168.
  • Jones LC, Hungerford DS. 1987. Cement disease. Clin Orthopaed Related Res. 225:192–206.
  • Judet J, Judet R. 1950. The use of an artificial femoral head for arthroplasty of the hip joint. J Bone Joint Surg. 32:166–173.
  • Judet R, Judet J. 1952. Technique and results with the acrylic femoral head prosthesis. J Bone Joint Surg. 34:173–180.
  • Kelley SS, Lachiewicz PF, Hickman JM, Paterno SM. 1998. Relationship of femoral head and acetabular size to the prevalence of dislocation. Clin Orthopaed Related Res. 355:163–170.
  • Kim PR, Beaule PE, Laflamme GY, Dunbar M. 2008. Causes of early failure in a multicenter clinical trial of hip resurfacing. J Arthroplasty. 23:44–49.
  • Kim RH, Dennis DA, Carothers JT. 2008. Metal-on-metal total hip arthroplasty. J Arthroplasty. 23:44–46.
  • Kim SY, Kyung HS, Ihn JC, Cho MR, Koo KH, Kim CY. 2004. Cementless Metasul metal-on-metal total hip arthroplasty in patients less than fifty years old. J Bone Joint Surg. 86:2475–2481.
  • Kinne RW, Kunisch E, Beensen V, Zimmermann T, Emmrich F, Petrow P, Lungershausen W, Hein G, Braun RK, Foerster M, et al. 2003. Synovial fibroblasts and synovial macrophages from patients with rheumatoid arthritis and other inflammatory joint diseases show chromosomal aberrations. Genes Chromosom Cancer. 38:53–67.
  • Kinne RW, Liehr T, Beensen V, Kunisch E, Zimmermann T, Holland H, Pfeiffer R, Stahl HD, Lungershausen W, Hein G, et al. 2001. Mosaic chromosomal aberrations in synovial fibroblasts of patients with rheumatoid arthritis, osteoarthritis, and other inflammatory joint diseases. Arthritis Res. 3:319–330.
  • Knight SR, Aujla R, Biswas SP. 2011. Total hip arthroplasty – over 100 years of operative history. Orthoped Rev. 3:72–74.
  • Korovessis P, Petsinis G, Repanti M. 2003. Zweymueller with metal-on-metal articulation: clinical, radiological and histological analysis of short-term results. Arch Orthop Trauma Surg. 123:5–11.
  • Korovessis P, Petsinis G, Repanti M, Papazisis Z, Iliopoulos P, Soucacos PN. 2002. Short-term results with the Zweymueller-SL metal-on-metal total hip arthroplasty. Eur J Orthop Surg Traumatol. 12:81–89.
  • Kothari M, Bartel DL, Booker JF. 1996. Surface geometry of retrieved McKee–Farrar total hip replacements. Clin Orthopaed Related Res. 329:S141–S147.
  • Kovochich M, Fung ES, Donovan E, Unice KM, Paustenbach DJ, Finley BL. 2018. Characterization of wear debris from metal-on-metal hip implants during normal wear versus edge-loading conditions. J Biomed Mater Res Part B: Appl Biomater. 106:986–996.
  • Krochtengel J. 2017. 4th Bellwether Over J&J metal hip implants kicks off. Law360 (New York).
  • Kurtz SM. 2009. UHMWPE biomaterials handbook: ultra high molecular weight polyethylene in total joint replacement and medical devices. 2nd ed. Boston (MA): Elsevier/Academic Press.
  • Kurtz SM, Kocagoz SB, Hanzlik JA, Underwood RJ, Gilbert JL, Macdonald DW, Lee GC, Mont MA, Kraay MJ, Klein GR, et al. 2013. Do ceramic femoral heads reduce taper fretting corrosion in hip arthroplasty? A retrieval study. Clin Orthop Relat Res. 471:3270–3282.
  • Kurtz SM, Ong KL, Lau E, Greenwald AS, Bozic K. 2013b. Prevalence of metal-on-metal bearings in the United States. In: Kurtz SM, Greenwald AS, Mihalko WM, Lemons JE, editors. Metal-on-metal total hip replacement devices. Selected technical papers STP1560. West Conshohocken (PA): ASTM International.
  • Kwon YM, Jacobs JJ, Macdonald SJ, Potter HG, Fehring TK, Lombardi AV. 2012. Evidence-based understanding of management perils for metal-on-metal hip arthroplasty patients. J Arthroplasty. 27:20–25.
  • Kwon YM, Lombardi AV, Jacobs JJ, Fehring TK, Lewis CG, Cabanela ME. 2014. Risk stratification algorithm for management of patients with metal-on-metal hip arthroplasty: consensus statement of the American Association of Hip and Knee Surgeons, the American Academy of Orthopaedic Surgeons, and the Hip Society. J Bone Joint Surg. 96:e1–e4.
  • Kwon Y-M, Thomas P, Summer B, Pandit H, Taylor A, Beard D, Murray DW, Gill HS. 2010. Lymphocyte proliferation responses in patients with pseudotumors following metal-on-metal hip resurfacing arthroplasty. J Orthopaed Res. 28:444–450.
  • Lainiala O, Eskelinen A, Elo P, Puolakka T, Korhonen J, Moilanen T. 2014. Adverse reaction to metal debris is more common in patients following MoM total hip replacement with a 36 mm femoral head than previously thought: results from a modern MoM follow-up programme. Bone Joint J. 96-B:1610–1617.
  • Langton DJ, Jameson SS, Joyce TJ, Hallab NJ, Natu S, Nargol AV. 2010. Early failure of metal-on-metal bearings in hip resurfacing and large-diameter total hip replacement: a consequence of excess wear. J Bone Joint Surg. 92:38–46.
  • Langton DJ, Sidaginamale R, Lord JK, Nargol AV, Joyce TJ. 2012. Taper junction failure in large-diameter metal-on-metal bearings. Bone Joint Res. 1:56–63.
  • Lass R, Grubl A, Kolb A, Domayer S, Csuk C, Kubista B, Giurea A, Windhager R. 2014. Primary cementless total hip arthroplasty with second-generation metal-on-metal bearings: a concise follow-up, at a minimum of seventeen years, of a previous report. J Bone Joint Surg. 96:e37.
  • Learmonth ID, Young C, Rorabeck C. 2007. The operation of the century: total hip replacement. Lancet. 370:1508–1519.
  • Lehil MS, Bozic KJ. 2014. Trends in total hip arthroplasty implant utilization in the United States. J Arthroplasty. 29:1915–1918.
  • Leikin JB, Karydes HC, Whiteley PM, Wills BK, Cumpston KL, Jacobs JJ. 2013. Outpatient toxicology clinic experience of patients with hip implants. Clin Toxicol. 51:230–236.
  • Leslie IJ, Williams S, Isaac G, Ingham E, Fisher J. 2009. High cup angle and microseparation increase the wear of hip surface replacements. Clin Orthop Relat Res. 467:2259–2265.
  • Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR. 1978. Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg. 60:217–220.
  • Lhotka C, Szekeres T, Steffan I, Zhuber K, Zweymüller K. 2003. Four-year study of cobalt and chromium blood levels in patients managed with two different metal-on-metal total hip replacements. J Orthop Res. 21:189–195.
  • Lilikakis AK, Arora A, Villar RN. 2005. Early rehabilitation comparing hip resurfacing and total hip replacement. Hip Int. 15:189.
  • Lohmann CH, Nuechtern JV, Willert HG, Junk-Jantsch S, Ruether W, Pflueger G. 2007. Hypersensitivity reactions in total hip arthroplasty. Orthopedics. 30:760–761.
  • Lombardi AV Jr, Barrack RL, Berend KR, Cuckler JM, Jacobs JJ, Mont MA, Schmalzried TP. 2012. The Hip Society: algorithmic approach to diagnosis and management of metal-on-metal arthroplasty. J Bone Joint Surg. 94:14–18.
  • Lombardi AV Jr, Mallory TH, Alexiades MM, Cuckler JM, Faris PM, Jaffe KA, Keating EM, Nelson CL Jr, Ranawat CS, Williams J, et al. 2001. Short-term results of the M2a-taper metal-on-metal articulation. J Arthroplasty.16:122–128.
  • Lombardi AV Jr, Mallory TH, Cuckler JM, Williams J, Berend KR, Smith TM. 2004. Mid-term results of a polyethylene-free metal-on-metal articulation. J Arthroplasty. 19:42–47.
  • Long WT. 2005. The clinical performance of metal-on-metal as an articulation surface in total hip replacement. Iowa Orthop J. 25:10–16.
  • Long WT, Dastane M, Harris MJ, Wan Z, Dorr LD. 2010. Failure of the Durom Metasul acetabular component. Clin Orthop Relat Res. 468:400–405.
  • Long WT, Dorr LD, Gendelman V. 2004. An American experience with metal-on-metal total hip arthroplasties: a 7-year follow-up study. J Arthroplasty. 19:29–34.
  • Lu F, Royle M, Lali FV, Hart AJ, Collins S, Housden J, Shelton JC. 2012. Simple isolation method for the bulk isolation of wear particles from metal on metal bearing surfaces generated in a hip simulator test. J Mater Sci Mater Med. 23:891–901.
  • MacDonald SJ. 2004. Metal-on-metal total hip arthroplasty: the concerns. Clin Orthopaed Related Res. 429:86–93.
  • MacDonald SJ, McCalden RW, Chess DG, Bourne RB, Rorabeck CH, Cleland D, Leung F. 2003. Metal-on-metal versus polyethylene in hip arthroplasty: a randomized clinical trial. Clin Orthopaed Related Res. 406:282–296.
  • Machado C, Appelbe A, Wood R. 2012. Arthroprosthetic cobaltism and cardiomyopathy. Heart Lung Circ. 21:759–760.
  • Madl AK, Kovochich M, Liong M, Finley BL, Paustenbach DJ, Oberdorster G. 2015. Toxicology of wear particles of cobalt-chromium alloy metal-on-metal hip implants. Part II: importance of physicochemical properties and dose in animal and in vitro studies as a basis for risk assessment. Nanomedicine. 11:1285–1298.
  • Madl AK, Liong M, Kovochich M, Finley BL, Paustenbach DJ, Oberdorster G. 2015. Toxicology of wear particles of cobalt-chromium alloy metal-on-metal hip implants. Part I: physicochemical properties in patient and simulator studies. Nanomedicine. 11:1201–1215.
  • Mahendra G, Pandit H, Kliskey K, Murray D, Gill HS, Athanasou N. 2009. Necrotic and inflammatory changes in metal-on-metal resurfacing hip arthroplasties. Acta Orthop. 80:653–659.
  • Makela KT, Visuri T, Pulkkinen P, Eskelinen A, Remes V, Virolainen P, Junnila M, Pukkala E. 2012. Risk of cancer with metal-on-metal hip replacements: population based study. BMJ. 345:e4646.
  • Makela KT, Visuri T, Pulkkinen P, Eskelinen A, Remes V, Virolainen P, Junnila M, Pukkala E. 2014. Cancer incidence and cause-specific mortality in patients with metal-on-metal hip replacements in Finland. Acta Orthopaed. 85:32–38.
  • Mao X, Wong AA, Crawford RW. 2011. Cobalt toxicity—an emerging clinical problem in patients with metal-on-metal hip prostheses? Med J Austral. 194:649–651.
  • Marker DR, Seyler TM, Jinnah RH, Delanois RE, Ulrich SD, Mont MA. 2007. Femoral neck fractures after metal-on-metal total hip resurfacing. A prospective cohort study. J Arthroplasty. 22:66–71.
  • Matharu GS, Hunt LP, Murray DW, Howard P, Pandit HG, Blom AW, Bolland B, Judge A. 2018. Is the rate of revision of 36 mm metal-on-metal total hip arthroplasties with Pinnacle acetabular components related to the year of the initial operation? An interrupted time-series analysis using data from the National Joint Registry for England and Wales. Bone Joint J. 100-B:33–41.
  • Matharu GS, Mellon SJ, Murray DW, Pandit HG. 2015. Follow-up of metal-on-metal hip arthroplasty patients is currently not evidence based or cost effective. J Arthroplasty. 30:1317–1323.
  • Matsushita A, Nakashima Y, Jingushi S, Yamamoto T, Kuraoka A, Iwamoto Y. 2009. Effects of the femoral offset and the head size on the safe range of motion in total hip arthroplasty. J Arthroplasty. 24:646–651.
  • Matthies AK, Racasan R, Bills P, Blunt L, Cro S, Panagiotidou A, Blunn G, Skinner J, Hart AJ. 2013. Material loss at the taper junction of retrieved large head metal-on-metal total hip replacements. J Orthopaed Res. 31:1677–1685.
  • McBride ED. 1952. A femoral head prosthesis for the hip joint; four years' experience and the results. J Bone Joint Surg. 34:989–996.
  • McEvoy C. 2013 Mar 8. DePuy hit with $8.3M verdict over metal hip implant. Law360 (New York).
  • McKee GK. 1970. Development of total prosthetic replacement of the hip. Clin Orthopaed Related Res. 72:85–103.
  • McKee GK, Chen SC. 1973. The statistics of the McKee–Farrar method of total hip replacement. Clin Orthopaed Related Res. 95:26–33.
  • McKee GK, Watson-Farrar J. 1966. Replacement of arthritic hips by the McKee–Farrar prosthesis. J Bone Joint Surg. 48:245–259.
  • McKellop H, Park SH, Chiesa R, Doorn P, Lu B, Normand P, Grigoris P, Amstutz H. 1996. In vivo wear of three types of metal on metal hip prostheses during two decades of use. Clin Orthopaed Related Res. 329:S128–S140.
  • McMinn D, Daniel J. 2006. History and modern concepts in surface replacement. Proc Inst Mech Eng H. 220:239–251.
  • McMinn D, Treacy R, Lin K, Pynsent P. 1996. Metal on metal surface replacement of the hip. Experience of the McMinn prothesis. Clin Orthopaed Related Res. 329:S89–S98.
  • Merritt K, Brown SA. 1996. Distribution of cobalt chromium wear and corrosion products and biologic reactions. Clin Orthopaed Related Res. 329:S233–S243.
  • MHRA (Medicines and Healthcare Products Regulatory Agency). 2010. All metal-on-metal (MOM) hip replacements. London: Medicines and Healthcare Products Regulatory Agency.
  • MHRA (Medicines and Healthcare Products Regulatory Agency). 2012. All metal-on-metal (MOM) hip replacements. London: Medicines and Healthcare Products Regulatory Agency.
  • MHRA (Medicines and Healthcare Products Regulatory Agency). 2017. All metal-on-metal (MOM) hip replacements: updated advice for follow-up of patients. London: Medicines and Healthcare Products Regulatory Agency.
  • Migaud H, Jobin A, Chantelot C, Giraud F, Laffargue P, Duquennoy A. 2004. Cementless metal-on-metal hip arthroplasty in patients less than 50 years of age: comparison with a matched control group using ceramic-on-polyethylene after a minimum 5-year follow-up. J Arthroplasty. 19:23–28.
  • Migaud H, Putman S, Combes A, Berton C, Bocquet D, Vasseur L, Girard J. 2012. Metal-on-metal bearing: is this the end of the line? We do not think so. Hss J. 8:262–269.
  • Monnot AD, Christian WV, Paustenbach DJ, Finley BL. 2014. Correlation of blood Cr(III) and adverse health effects: application of PBPK modeling to determine non-toxic blood concentrations. Crit Rev Toxicol. 44:618–637.
  • Monteiller C, Tran L, MacNee W, Faux S, Jones A, Miller B, Donaldson K. 2007. The pro-inflammatory effects of low-toxicity low-solubility particles, nanoparticles and fine particles, on epithelial cells in vitro: the role of surface area. Occupat Environ Med. 64:609–615.
  • Moore AT. 1952. Metal hip joint; a new self-locking vitallium prosthesis. South Med J. 45:1015–1019.
  • Morlock MM. 2015. The taper disaster-how could it happen? Hip Int. 25:339–346.
  • Morrey BF. 2003. Dislocation. In: Morrey BF, Lewallen DG, editors. Joint replacement arthroplasty. Philadelphia (PA): Churchill Livingstone.
  • Muller ME. 1995. The benefits of metal-on-metal total hip replacements. Clin Orthopaed Related Res. 311:54–59.
  • Nassif NA, Nawabi DH, Stoner K, Elpers M, Wright T, Padgett DE. 2014. Taper design affects failure of large-head metal-on-metal total hip replacements. Clin Orthop Relat Res. 472:564–571.
  • Newington DP, Bannister GC, Fordyce M. 1990. Primary total hip replacement in patients over 80 years of age. J Bone Joint Surg Br. 72:450–452.
  • NHS. 2012. Hip replacement – why it is necessary; [accessed 2013 Nov 26]. http://www.nhs.uk/Conditions/Hip-replacement/Pages/Why-it-should-be-done.aspx.
  • NICE (National Institute for Health and Care Excellence). 2014. Total hip replacement and resurfacing arthroplasty for end-state arthritis of the hip. London: National Institute for Health and Care Excellence.
  • NIH (National Institutes of Health). 1982. Total hip joint replacement. National Institutes of Health Consensus Development Conference Statement, March 1–3, 1982; [accessed 2012 Nov 27]. https://consensus.nih.gov/1982/1982hipreplacement033html.htm.
  • NIH (National Institutes of Health). 1994. Total hip replacement. NIH Consensus Development Statement, September 12–14, 1994; [accessed 2012 Aug 29]. https://consensus.nih.gov/1994/1994HipReplacement098html.htm.
  • Nikolaou V, Petit A, Khoury V, Blain-Pare E, Zukor D, Huk O, Antoniou J. 2015. Magnetic resonance imaging of painful metal-on-metal total hip replacement. Eur J Orthop Surg Traumatol. 25:313–319.
  • Nilsdotter A, Bremander A. 2011. Measures of hip function and symptoms: Harris Hip Score (HHS), Hip Disability and Osteoarthritis Outcome Score (HOOS), Oxford Hip Score (OHS), Lequesne Index of Severity for Osteoarthritis of the Hip (LISOH), and American Academy of Orthopedic Surgeons (AAOS) Hip and Knee Questionnaire. Arthritis Care Res. 63:S200–S207.
  • NJR (National Joint Registry U.K.). 2011. National Joint Registry for England and Wales: 8th Annual Report 2011. Hemel Hempstead: National Joint Registry.
  • Northup SJ. 1989. Current problems associated with toxicity evaluation of medical device materials and future research needs. Fundamental Appl Toxicol. 13:196–204.
  • Nyren O, McLaughlin JK, Gridley G, Ekbom A, Johnell O, Fraumeni JF Jr, Adami HO. 1995. Cancer risk after hip replacement with metal implants: a population-based cohort study in Sweden. J Natl Cancer Inst. 87:28–33.
  • NZOA (New Zealand Orthopaedic Association). 2009. The New Zealand Joint Registry Ten Year Report: January 1999 to December 2008. Wellington (NZ): New Zealand Orthopaedic Association.
  • Oberdorster G, Ferin J, Lehnert BE. 1994. Correlation between particle size, in vivo particle persistence, and lung injury. Environ Health Perspect. 102:173–179.
  • Oberdorster G, Oberdorster E, Oberdorster J. 2005. Nanotoxicology: an emerging discipline evolving from studies of ultrafine particles. Environ Health Perspect. 113:823–839.
  • Oldenburg M, Wegner R, Baur X. 2009. Severe cobalt intoxication due to prosthesis wear in repeated total hip arthroplasty. J Arthroplasty. 24:825.e15–825.e20.
  • Onega T, Baron J, MacKenzie T. 2006. Cancer after total joint arthroplasty: a meta-analysis. Cancer Epidemiol Biomark Prevent. 15:1532–1537.
  • O'Neill DA, Harris WH. 1984. Failed total hip replacement: assessment by plain radiographs, arthrograms, and aspiration of the hip joint. J Bone Joint Surg Am. 66:540–546.
  • OSMA (Orthopaedic Surgical Manufacturers Association). 2000. Petition for reclassification for metal/metal semi-constrained hip joint prosthesis. Germantown (TN): Orthopaedic Surgical Manufacturers Association.
  • OSMA (Orthopaedic Surgical Manufacturers Association). 2005. Reclassification petition for metal/metal semi-constrained hip joint prosthesis with cemented or uncemented acetabular components. Germantown (TN): Orthopaedic Surgical Manufacturers Association.
  • OSMA (Orthopaedic Surgical Manufacturers Association). 2007 Jan 24. Reclassification petition for metal/metal semiconstrained hip joint prostheses with cemented or uncemented acetabular components 21 CFR 888.3320 and 888.3330 Docket Number 2005P-0405; [accessed 2017 Mar 3]. https://www.fda.gov/ohrms/dockets/dockets/05p0405/05p-0405-sup0001-01-vol5.pdf.
  • Packer M. 2016. Cobalt cardiomyopathy: a critical reappraisal in light of a recent resurgence. Circ Heart Fail. 9. pii:e003604.
  • Pandit H, Glyn-Jones S, McLardy-Smith P, Gundle R, Whitwell D, Gibbons CL, Ostlere S, Athanasou N, Gill HS, Murray DW. 2008. Pseudotumours associated with metal-on-metal hip resurfacings. J Bone Joint Surg. 90:847–851.
  • Papageorgiou I, Brown C, Schins R, Singh S, Newson R, Davis S, Fisher J, Ingham E, Case CP. 2007. The effect of nano- and micron-sized particles of cobalt–chromium alloy on human fibroblasts in vitro. Biomaterials. 28:2946–2958.
  • Park K, Jang J, Irimia D, Sturgis J, Lee J, Robinson JP, Toner M, Bashir R. 2008. 'Living cantilever arrays' for characterization of mass of single live cells in fluids. Lab Chip. 8:1034–1041.
  • Park YS, Moon YW, Lim SJ, Yang JM, Ahn G, Choi YL. 2005. Early osteolysis following second-generation metal-on-metal hip replacement. J Bone Joint Surg. 87:1515–1521.
  • Parry MC, Bhabra G, Sood A, Machado F, Cartwright L, Saunders M, Ingham E, Newson R, Blom AW, Case CP. 2010. Thresholds for indirect DNA damage across cellular barriers for orthopaedic biomaterials. Biomaterials. 31:4477–4483.
  • Paterson JM. 1987. An unusual presentation of osteoarthritis of the hip. J Bone Joint Surg. 69:480–480.
  • Paustenbach DJ, Galbraith DA, Finley BL. 2014. Interpreting cobalt blood concentrations in hip implant patients. Clin Toxicol. 52:98–112.
  • Paustenbach DJ, Tvermoes BE, Unice KM, Finley BL, Kerger BD. 2013. A review of the health hazards posed by cobalt. Crit Rev Toxicol. 43:316–362.
  • Pazzaglia UE, Apostoli P, Congiu T, Catalani S, Marchese M, Zarattini G. 2011. Cobalt, chromium and molybdenum ions kinetics in the human body: data gained from a total hip replacement with massive third body wear of the head and neuropathy by cobalt intoxication. Arch Orthop Trauma Surg. 131:1299–1308.
  • Pedersen NT. 1978. Evaluation of painful hip arthroplasty. Acta Orthop Scand. 49:384–388.
  • Pelclova D, Sklensky M, Janicek P, Lach K. 2012. Severe cobalt intoxication following hip replacement revision: clinical features and outcome. Clin Toxicol. 50:262–265.
  • Peltier LF. 2007. A history of hip surgery. In: Callaghan JJ, Rosenberg AG, Rubash HE, editors. The adult hip. 2nd ed. Vol. 1. Philadelphia (PA): Lippincott Williams & Wilkins.
  • Penkava RR. 1980. Iliopsoas bursitis demonstrated by computed tomography. AJR. 135:175–176.
  • Pepper HW, Noonan CD. 1973. Radiographic evaluation of total hip arthroplasty. Radiology. 108:23–29.
  • Polyzois I, Nikolopoulos D, Michos I, Patsouris E, Theocharis S. 2012. Local and systemic toxicity of nanoscale debris particles in total hip arthroplasty. J Appl Toxicol. 32:255–269.
  • Postel M, Kerboul M, Evrard J, Courpied JP. 1987. The development of total hip replacement. In: Postel M, Kerboul M, Evrard J, Courpied JP. Total hip replacement. Berlin: Springer.
  • Pourzal R, Catelas I, Theissmann R, Kaddick C, Fischer A. 2011. Characterization of wear particles generated from CoCrMo alloy under sliding wear conditions. Wear. 271:1658–1666.
  • Reito A, Elo P, Puolakka T, Pajamaki J, Nieminen J, Eskelinen A. 2014. Repeated magnetic resonance imaging in 154 hips with large-diameter metal-on-metal hip replacement. Acta Orthopaed. 85:570–576.
  • Reito A, Puolakka T, Pajamaki J. 2011. Birmingham hip resurfacing: five to eight year results. Int Orthop. 35:1119–1124.
  • Rieker CB, Weber H, Schon R, Windler M, Wyss UP. 1999. Development of the METASUL articulations. In: Rieker C, Windler M, Wyss U. Metasul: a metal-on-metal bearing. Bern (Switzerland): Hans Huber.
  • Ring PA. 1968. Complete replacement arthroplasty of the hip by the ring prosthesis. J Bone Joint Surg. 50:720–731.
  • Ring PA. 1978. Five to fourteen year interim results of uncemented total hip arthroplasty. Clin Orthopaed Related Res. 137:87–95.
  • Ritter MA. 1976. Dislocation and subluxation of the total hip replacement. Clin Orthopaed Related Res. 121:92–94.
  • Rizzetti MC, Liberini P, Zarattini G, Catalani S, Pazzaglia U, Apostoli P, Padovani A. 2009. Loss of sight and sound. Could it be the hip? Lancet. 373:1052
  • Ryan G. 2012 Aug 9. Stryker hit with 1st metal hip implant suit since recall. Law360 (New York).
  • Sabah SA, Mitchell AW, Henckel J, Sandison A, Skinner JA, Hart AJ. 2011. Magnetic resonance imaging findings in painful metal-on-metal hips: a prospective study. J Arthroplasty. 26:71–76.
  • Salvati EA, Wilson PD Jr, Jolley MN, Vakili F, Aglietti P, Brown GC. 1981. A ten-year follow-up study of our first one hundred consecutive Charnley total hip replacements. J Bone Joint Surg. 63:753–767.
  • Sampson B, Hart A. 2012. Clinical usefulness of blood metal measurements to assess the failure of metal-on-metal hip implants. Ann Clin Biochem. 49:118–131.
  • Savarino L, Granchi D, Ciapetti G, Cenni E, Nardi Pantoli A, Rotini R, Veronesi CA, Baldini N, Giunti A. 2002. Ion release in patients with metal-on-metal hip bearings in total joint replacement: a comparison with metal-on-polyethylene bearings. J Biomed Mater Res. 63:467–474.
  • Scales JT. 1966. Paper 13: arthroplasty of the hip using foreign materials: a history. Proc Inst Mech Eng Conf Proc. 181:63–84.
  • SCENIHR (Scientific Committee on Emerging and Newly Identified Health Risks). 2014. Scientific Committee on Emerging and Newly Identified Health Risks (SCENIHR) opinion on the safety of metal-on-metal joint replacements with a particular focus on hip implants. Luxembourg: European Commission.
  • Schalock PC, Crawford G, Nedorost S, Scheinman PL, Atwater AR, Mowad C, Brod B, Ehrlich A, Watsky KL, Sasseville D, et al. 2016. Patch testing for evaluation of hypersensitivity to implanted metal devices: a perspective from the American Contact Dermatitis Society. Dermatitis. 27:241–247.
  • Schalock PC, Menne T, Johansen JD, Taylor JS, Maibach HI, Liden C, Bruze M, Thyssen JP. 2012. Hypersensitivity reactions to metallic implants – diagnostic algorithm and suggested patch test series for clinical use. Contact Dermatitis. 66:4–19.
  • Schmalzried TP, Szuszczewicz ES, Akizuki KH, Petersen TD, Amstutz HC. 1996. Factors correlating with long term survival of McKee–Farrar total hip prostheses. Clin Orthopaed Related Res. 329:S48–S59.
  • Schmidt M, Weber H, Sch??n R. 1996. Cobalt chromium molybdenum metal combination for modular hip prostheses. Clin Orthopaed Related Res. 329:S35–S47.
  • Sedrakyan A, Paxton EW, Phillips C, Namba R, Funahashi T, Barber T, Sculco T, Padgett D, Wright T, Marinac-Dabic D. 2011. The International Consortium of Orthopaedic Registries: overview and summary. J Bone Joint Surg. 93:1–12.
  • Semlitsch M, Willert HG. 1997. Clinical wear behaviour of ultra-high molecular weight polyethylene cups paired with metal and ceramic ball heads in comparison to metal-on-metal pairings of hip joint replacements. Proc Inst Mech Eng H. 211:73–88.
  • Seppanen M, Karvonen M, Virolainen P, Remes V, Pulkkinen P, Eskelinen A, Liukas A, Makela KT. 2016. Poor 10-year survivorship of hip resurfacing arthroplasty. Acta Orthop. 87:554–559.
  • Sershon R, Balkissoon R, Valle CJ. 2016. Current indications for hip resurfacing arthroplasty in 2016. Curr Rev Musculoskelet Med. 9:84–92.
  • Shemesh S, Kosashvili Y, Heller S, Sidon E, Yaari L, Cohen N, Velkes S. 2014. Hip arthroplasty with the articular surface replacement (ASR) system: survivorship analysis and functional outcomes. Eur J Orthop Surg Traumatol. 24:925–930.
  • Shimmin A, Beaule PE, Campbell P. 2008. Metal-on-metal hip resurfacing arthroplasty. J Bone Joint Surg. 90:637–654.
  • Sidaginamale RP, Joyce TJ, Lord JK, Jefferson R, Blain PG, Nargol AV, Langton DJ. 2013. Blood metal ion testing is an effective screening tool to identify poorly performing metal-on-metal bearing surfaces. Bone Joint Res. 2:84–95.
  • Siebel T, Maubach S, Morlock MM. 2006. Lessons learned from early clinical experience and results of 300 ASR hip resurfacing implantations. Proc Inst Mech Eng H. 220:345–353.
  • Signorello LB, Ye W, Fryzek JP, Lipworth L, Fraumeni JF, Blot WJ, McLaughlin JK, Nyrén O. 2001. Nationwide study of cancer risk among hip replacement patients in Sweden. J Natl Cancer Inst. 93:1405–1410.
  • Skipor AK, Campbell PA, Patterson LM, Anstutz HC, Schmalzried TP, Jacobs JJ. 2002. Serum and urine metal levels in patients with metal-on-metal surface arthroplasty. J Mater Sci Mater Med. 13:1227–1234.
  • Smith Nephew. 2012. Voluntary market withdrawal of the optional metal liner with the R3 acetabular system. New York: Smith & Nephew.
  • Smith TM, Berend KR, Lombardi AV Jr, Emerson RH Jr, and Mallory TH. 2005. Metal-on-metal total hip arthroplasty with large heads may prevent early dislocation. Clin Orthopaed Related Res. 441:137–142.
  • Smith AJ, Dieppe P, Vernon K, Porter M, Blom AW. 2012. Failure rates of stemmed metal-on-metal hip replacements: analysis of data from the National Joint Registry of England and Wales. Lancet. 379:1199–1204.
  • Smith SL, Dowson D, Goldsmith AA. 2001. The effect of femoral head diameter upon lubrication and wear of metal-on-metal total hip replacements. Proc Inst Mech Eng H. 215:161–170.
  • Smith E, Harris WH. 1995. Increasing prevalence of femoral lysis in cementless total hip arthroplasty. J Arthroplasty. 10:407–412.
  • Smith-Petersen MN. 1939. Arthroplasty of the hip: a new method. J Bone Joint Surg. 21:269–288.
  • Steens W, von Foerster G, Katzer A. 2006. Severe cobalt poisoning with loss of sight after ceramic-metal pairing in a hip – a case report. Acta Orthopaed. 77:830–832.
  • Steinbach LS, Schneider R, Goldman AB, Kazam E, Ranawat CS, Ghelman B. 1985. Bursae and abscess cavities communicating with the hip. Diagnosis using arthrography and CT. Radiology. 156:303–307.
  • Stillwell WT, Hamati YI, Scott RD. 1987. The art of total hip arthroplasty. Orlando (FL): Grune & Stratton.
  • Stride M. 2013 Apr 16. Jury sides with DePuy at 2nd hip implant trial. Law360 (New York).
  • Stryker Orthopaedics. 2012 May 1. Memo re: urgent product correction. Product remediation #: RA 2012-067.
  • Stungis TE, Fink JN. 1969. Hypersensitivity to acrylic resin. J Prosthet Dent. 22:425–428.
  • Tamai O, Mamadi T, Muto Y, Toda T. 1998. Large synovial cyst of the pelvis containing rice bodies. A case report. Int Orthopaed. 22:325–327.
  • Tanzer M, Chan S, Brooks CE, Bobyn JD. 2001. Primary cementless total hip arthroplasty using a modular femoral component: a minimum 6-year follow-up. J Arthroplasty. 16:64–70.
  • Tardy N, Maqdes A, Boisrenoult P, Beaufils P, Oger P. 2015. Small diameter metal-on-metal total hip arthroplasty at 13 years – a follow-up study. Orthopaed Traumatol Surg Res. 101:929–936.
  • Thompson FR. 1953. Experiences with a vitallium intramedullary hip prosthesis. Texas State J Med. 49:749–756.
  • Thompson FR. 1954. Two and a half years' experience with a vitallium intramedullary hip prosthesis. J Bone Joint Surg. 36:489–502.
  • Thyssen JP, Menne T, Schalock PC, Taylor JS, Maibach HI. 2011. Pragmatic approach to the clinical work-up of patients with putative allergic disease to metallic orthopaedic implants before and after surgery. Br J Dermatol. 164:473–478.
  • Tkaczyk C, Petit A, Antoniou J, Zukor DJ, Tabrizian M, Huk OL. 2010. Significance of elevated blood metal ion levels in patients with metal-on-metal prostheses: an evaluation of oxidative stress markers. Open Orthop J. 4:221–227.
  • Toms AP, Marshall TJ, Cahir J, Darrah C, Nolan J, Donell ST, Barker T, Tucker JK. 2008. MRI of early symptomatic metal-on-metal total hip arthroplasty: a retrospective review of radiological findings in 20 hips. Clin Radiol. 63:49–58.
  • Tower S. 2010. Arthroprosthetic cobaltism: identification of the at-risk patient. Alaska Med. 52:28–32.
  • Tvermoes BE, Otani JM, Unice KM, Finley BL, Paustenbach DJ, Galbraith DA. 2012. A 14 day cobalt supplement study to investigate cobalt steady-state levels in five healthy adult volunteers. To be presented at 2012 Society for Risk Analysis (SRA) Annual Meeting; Dec 9–12; San Francisco (CA).
  • Tvermoes BE, Paustenbach DJ, Kerger BD, Finley BL, Unice KM. 2015. Review of cobalt toxicokinetics following oral dosing: implications for health risk assessments and metal-on-metal hip implant patients. Crit Rev Toxicol. 45:367–387.
  • Tvermoes BE, Unice KM, Paustenbach DJ, Finley BL, Otani JM, Galbraith DA. 2014. Effects and blood concentrations of cobalt after ingestion of 1 mg/d by human volunteers for 90 d. Am J Clin Nutr. 99:623–646.
  • Tvermoes BE, Unice KM, Winans B, Kovochich M, Christian WV, Donovan E, Fung ES, Finley BL, Kimber I, Paustenbach DJ. 2016. A preliminary evaluation of immune stimulation following exposure to metal particles and ions using the mouse popliteal lymph node assay. Toxicol Appl Pharmacol. 308:77–90.
  • Unice K, Monnot A, Gaffney SH, Tvermoes B, Thuett K, Paustenbach D, Finley B. 2012. Inorganic cobalt supplementation: prediction of cobalt levels in whole blood and urine using a biokinetic model. Food Chem Toxicol. 50:2456–2461.
  • USFDA (United States Food and Drug Administration). 1999. Memo from Celia M. Witten (USFDA) to Mitchell A. Dhority (Sulzer Orthopedics, Inc.), RE: K974728, Trade Name: Inter-Op Metasul Acetabular System, Regulatory Class: III, Product Code: KWA. Includes Attachment 510(k) Summary. Rockville (MD): U.S. Food and Drug Administration.
  • USFDA (United States Food and Drug Administration). 2012. FDA Executive Summary Memorandum. Metal-on-Metal Hip Implant Systems. Prepared for the June 27–28, 2012 Meeting of the Orthopaedic and Rehabilitation Devices Advisory Panel Gaithersburg Hilton, Gaithersburg, MD.
  • USFDA (United States Food and Drug Administration). 2013. Metal-on-metal hip implants: FDA safety communication. Date Issued: January 17, 2013. [accessed 2017 Feb 1]. http://www.fda.gov/MedicalDevices/Safety/AlertsandNotices/ucm335775.htm.
  • USFDA (United States Food and Drug Administration). 2014. Recalls. Silver Spring (MD): U.S. Food and Drug Administration; [accessed 2014 Jun 11]. http://www.fda.gov/medicaldevices/ProductsandMedicalProcedures/implantsandprosthetics/metalonmetalhipimplants/ucm241770.htm.
  • USFDA (United States Food and Drug Administration). 2015. Metal-on-metal hip implants. Information for orthopaedic surgeons; [accessed 2017 Mar 30]. https://www.fda.gov/MedicalDevices/ProductsandMedicalProcedures/ImplantsandProsthetics/MetalonMetalHipImplants/ucm241667.htm#3a.
  • USFDA (United States Food and Drug Administration). 2017. 510(k) premarket notification; [accessed 2017 Jan 26]. http://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfPMN/pmn.cfm.
  • Van Der Straeten C, De Smet KA. 2016. Current expert views on metal-on-metal hip resurfacing arthroplasty. Consensus of the 6th advanced Hip resurfacing course, Ghent, Belgium, May 2014. Hip Int. 26:1–7.
  • Van Der Straeten C, Grammatopoulos G, Gill HS, Calistri A, Campbell P, De Smet KA. 2013. The 2012 Otto Aufranc Award: the interpretation of metal ion levels in unilateral and bilateral hip resurfacing. Clin Orthop Relat Res. 471:377–385.
  • van Lingen CP, Ettema HB, Timmer JR, de Jong G, Verheyen CC. 2013. Clinical manifestations in ten patients with asymptomatic metal-on-metal hip arthroplasty with very high cobalt levels. Hip Int. 23:441–444.
  • Vermes C, Kuzsner J, Bardos T, Than P. 2013. Prospective analysis of human leukocyte functional tests reveals metal sensitivity in patients with hip implant. J Orthop Surg Res. 8:12.
  • Visuri T, Koskenvuo M. 1991. Cancer risk after McKee–Farrar total hip replacement. Orthopedics. 14:137–142.
  • Visuri T, Pukkala E, Paavolainen P, Pulkkinen P, Riska EB. 1996. Cancer risk after metal on metal and polyethylene on metal total hip arthroplasty. Clin Orthopaed Related Res. 329:S280–S289.
  • Visuri T, Pukkala E, Pulkkinen P, Paavolainen P. 2003. Decreased cancer risk in patients who have been operated on with total hip and knee arthroplasty for primary osteoarthrosis: a meta-analysis of 6 Nordic cohorts with 73,000 patients. Acta Orthopaed Scand. 74:351–360.
  • Wagner M, Wagner H. 1996. Preliminary results of uncemented metal on metal stemmed and resurfacing hip replacement arthroplasty. Clin Orthopaed Related Res. 329:S78–S88.
  • Wagner M, Wagner H. 2000. Medium-term results of a modern metal-on-metal system in total hip replacement. Clin Orthopaed Related Res. 379:123–133.
  • Walker PS, Gold BL. 1971. The tribology (friction, lubrication and wear) of all-metal artificial hip joints. Wear. 17:285–299.
  • Walsh CP, Hubbard JC, Nessler JP, Markel DC. 2015. MRI findings associated with recalled modular femoral neck rejuvenate and ABG implants. J Arthroplast. 30:2021–2026.
  • Waterman AH, Schrik JJ. 1985. Allergy in hip arthroplasty. Contact Derm. 13:294–301.
  • Weber BG. 1996. Experience with the Metasul total hip bearing system. Clin Orthopaed Related Res. 329S:S69–S77.
  • Weber BG, Semlitsch MF, Streicher RM. 1993. Total hip joint replacement using a CoCrMo metal-metal sliding pairing. Nihon Seikeigeka Gakkai Zasshi. 67:391–398.
  • Wiley KF, Ding K, Stoner JA, Teague DC, Yousuf KM. 2013. Incidence of pseudotumor and Acute Lymphocytic Vasculitis Associated Lesion (ALVAL) reactions in metal-on-metal hip articulations: a meta-analysis. J Arthroplasty. 28:1238–1245.
  • Wilkinson JM, Hamer AJ, Stockley I, Eastell R. 2005. Polyethylene wear rate and osteolysis: critical threshold versus continuous dose–response relationship. J Orthop Res. 23:520–525.
  • Willert HG. 1973. Tissue reactions around joint implants and bone cement. In: Chapchal G, editor. Arthroplasty of the hip. 5th International Symposium 1972 in Nijmegen, Netherlands. Stuttgart: Thieme.
  • Willert HG, Bertram H, Buchhorn GH. 1990. Osteolysis in alloarthroplasty of the hip. The role of ultra-high molecular weight polyethylene wear particles. Clin Orthopaed Related Res. 258:95–107.
  • Willert H-G, Buchhorn GH, Fayyazi A, Flury R, Windler M, Köster G, Lohmann CH. 2005. Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints: a clinical and histomorphological study. J Bone Joint Surg. 87:28–36.
  • Willert HG, Ludwig J, Semlitsch M. 1974. Reaction of bone to methacrylate after hip arthroplasty: a long-term gross, light microscopic, and scanning electron microscopic study. J Bone Joint Surg. 56:1368–1382.
  • Willert HG, Semlitsch M. 1977. Reactions of the articular capsule to wear products of artificial joint prostheses. J Biomed Mater Res. 11:157–164.
  • Willert HG, Semlitsch M, Buchhorn G, Kriete U. 1978. Wear of materials and tissue response in artificial. Orthopade. 7:62–83.
  • Willert HG, Semlitsch M. 1976. Ractions of the articular capsule to artificial joint prosthesis. In: Williams D, editor. Biocompatibility of implant materials. London: Sector Publishing.
  • Willert HG, Semlitsch M. 1975. Reaction of the articular capsule to plastic and metallic wear products from joint endoprostheses. Sulzer Techn Rev. 2:119–133.
  • Williams DH, Greidanus NV, Masri BA, Duncan CP, Garbuz DS. 2011. Prevalence of pseudotumor in asymptomatic patients after metal-on-metal hip arthroplasty. J Bone Joint Surg. 93:2164–2171.
  • Wilson JN, Scales JT. 1970. Loosening of total hip replacements with cement fixation. Clinical findings and laboratory studies. Clin Orthopaed Related Res. 72:145–160.
  • Wroblewski BM. 1985. Direction and rate of socket wear in Charnley low-friction arthroplasty. J Bone Joint Surg. 67:757–761.
  • Wroblewski BM. 1991. Clinical and radiographic evaluation of total hip replacement. A standard system of terminology for reporting results. J Bone Joint Surg. 73:948.
  • Wynn-Jones H, Macnair R, Wimhurst J, Chirodian N, Derbyshire B, Toms A, Cahir J. 2011. Silent soft tissue pathology is common with a modern metal-on-metal hip arthroplasty. Acta Orthop. 82:301–307.
  • Xia Z, Kwon YM, Mehmood S, Downing C, Jurkschat K, Murray DW. 2011. Characterization of metal-wear nanoparticles in pseudotumor following metal-on-metal hip resurfacing. Nanomedicine. 7:674–681.
  • Zahiri CA, Schmalzried TP, Ebramzadeh E, Szuszczewicz ES, Salib D, Kim C, Amstutz HC. 1999. Lessons learned from loosening of the McKee–Farrar metal-on-metal total hip replacement. J Arthroplasty. 14:326–332.
  • Zimmer. 2008. Background on Durom cup status: Zimmer temporarily suspends marketing and distribution of Durom acetabular component in the United States to update labeling and implement surgical technique training. Press Release Dated July 22, 2008. Warsaw, IN: Zimmer Holdings, Inc.
  • Zywiel MG, Cherian JJ, Banerjee S, Cheung AC, Wong F, Butany J, Gilbert C, Overgaard C, Syed K, Jacobs JJ, Mont MA. 2016. Systemic cobalt toxicity from total hip arthroplasties: review of a rare condition part 2. measurement, risk factors, and step-wise approach to treatment. Bone Joint J. 98-B:14–20.
  • Zywiel MG, Sayeed SA, Johnson AJ, Schmalzried TP, Mont MA. 2011. State of the art in hard-on-hard bearings: how did we get here and what have we achieved? Expert Rev Med Devices. 8:187–207.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.