- JOHNSON ,P., and ANDREWS, D. C., 1996, Remote continuous physiological monitoring in the home. Technical Report (Oxford, UK: Maternal Infant Care and Telemonitoring Centre, John Radcliffe Hospital).
- ?TAJER, D., GORUP, S., GORUP, Z., and RODE, A., 1994, High resolution ECG data storage and graphical presentation. Proceedings of the Thirteenth IASTED International Conference on Modelling, Identification and Control, Anaheim, CA, USA, pp. 23-25.
- MADHUKAR, B., and MURTHY, I. S. N., 1993, ECG data compression by modeling. Computers and Biomedical Research, 26(3), 310-317.
- KOHAMA, T., and NAKAMURA, S. 1994, Noise cancelling for the digital Holter monitoring system. Electronics and Communications in Japan, Part 3 (Fundamental Electronic Science), 77(12), 82-91.
- THOMSON, D. C., HAMILTON, D. J., and SANDHAM, W. A., 1995, Electrocardiogram data compression using artificial neural networks. Applied Signal Processing, 2(1), 16-23.
- EINARSSON, G., 1991, An improved implementation of predictive coding compression. IEEE Transactions on Communications, 39(2), 169-171.
- TSUDA, S., SHIMIZU , K, and MATSUMOTO, G., 1993, Efficient application of coding technique for data compression of ECG. IEICE Transactions on Information and Systems, E76-D(12), 1425-1433.
- HAMILTON, P. S., and TOMPKINS,W. J., 1991,Compression of the ambulatory ECG by average beat subtraction and residual differencing. IEEE Transactionson Biomedical Engineering, 38(3), 253-259.
- PAGGETTI, C., LUSINI, M., VARANINI, M., TADDEI, A., and MARCHESI, C., 1994, A multichannel template based data compression algorithm. Proceedings of Computers m Cardiology (Los Alamitos, CA, USA: IEEE Computer Society Press), pp. 629-632.
- UCHIYAMA, T., AKAZAWA, K., and SASAMORI, A., 1993, Data compression of ambulatory ECG by using multi-template matching and residual coding. IEICE Transactionson Information and Systems, E76-D(12), 1419-1424.
- AYDIN, M. C., ÇETIN, A. E., and KÖYMEN, H., 1991, ECG data compression by sub-band coding. Electronics Letters, 27(4), 359-360.
- AASE, S. O., 1995, Filter bank design for subband compression of ECG signals. Proceedings of the Norwegian Signal Processing Sysmposium (NORSIG'95), Hogskolen, Stavanger, Norway, pp 113-118.
- TAI, S. C., 1995, Improving the performance of electrocardiogram sub-band coder by extensive Markov system. Medical and Biological Engineering and Computing, 33(3), 471-475.
- HUSOY, J. H., and GJERDE, T. 1996, Computationally efficient sub-band coding of ECG signals. Medical Engineering and Physics, 18(2), 132-142.
- COX, J. R., NOLLE, F. M., FOZZARD, H. A., and OLIVER, G. C., 1968, AZTEC, a preprocessing algorithm for real-time ECG rhythm analysis. IEEE Transactions on Biomedical Engineering, 15(4), 128-129.
- MUELLER, W. C., 1978, Arrhythmia detection program for an ambulatory ECG monitor. Biomedical Scientific Instrumentation, 14, 81-85.
- BLANCHARD, S. M., and BARR, R. C., 1985, Comparison of methods for adaptive sampling of cardiac electrograms and electrocardiograms. Medical and Biological Engineering and Computing, 23, 377-386.
- ISHUIMA, M., SHIN, S. B., HOSTETTER, G. H., and SKLANSKY, J., 1983, Scan-along polygonal approximation for data compression of electrocardiograms. IEEE Transactions on Biomedical Engineering, 30(11), 723-729.
- FADALI, M. S., and DWYER, T. A. W., 1986, Compact storage and reconstruction of periodic signals by means of a reproducing kernel. Microcomputer Applications, 5(3), 79-83.
- SAITOH, Y., HASEGAWA, Y., KIRYU, T., and HORI, J., 1993, Electrocardiogram data compression by the Oslo algorithm and DP matching. IEICE Transactions on Information and Systems, E76-D(12), 1411-1418.
- IMAI, H., KIMURA, N., and YOSHIDA, Y., 1985, An efficient encoding method for electrocardiography suing spline functions. Systems and Computers in Japan, 16(3), 85-94.
- McAULIFFE, J. D., 1993, Data compression of the exercise ECG using a Kohonen neural network. Journal of Electrocardiology, 26 (Suppl.), 80-89.
- HAMILTON, D. J., THOMSON, D. C., and SANDHAM, W. A., 1995, ANN Compression of morphologically similar ECG complexes. Medical and Biological Engineering and Computing, 33(6), 841-843.
- MORITA, H., and KOBAYASHI, K., 1993, Data compression of ECG based on the edit distance algorithms. IEICE Transactions on Information and Systems, E76-D(12), 1443-1453.
- BARLAS, G. D., and SKORDALAKIS, E. S., 1996, A novel family of compression algorithms for ECG and other semiperiodical, one-dimensional, biomedical signals. IEEE Transactions on Biomedical Engineering, 43(8), 820-828.
- ABENSTEIN, J. P., and TOMPKINS, W. J., 1982, New data-reduction algorithm for real-time ECG analysis. IEEE Transactions on Biomedical Engineering, 29, 43-48.
- PASSARIELLO, G., GAVIDIA, L., RODRIGUEZ, F., CONDADO, J., RUESTA, V., Roux, C., and MORA, F., 1991, Arithmetic coding for ECG data compression. Proceedings of Computers in Cardiology (Los Alanritos, CA, USA: IEEE Computer Society Press), pp. 593-596.
- JALALEDDINE, S. M. S., and HUTCHENS, C. G., 1990, SAIES: a new ECG data compression algorithm. Journal of Clinical Engineering, 15(1), 45-51.
- SHAHEIN, H. I., and ABBAS, H. M., 1994, ECG data compression via cubic-splines and scan-along polygonal approximation. Signal Processing, 35(3), 269-283.
- ODAIYAPPAN ,P.,and KUMAR, K. S.,1994,ECG data compression techniques using microprocessors. Advances in Modelling and Analysis B, 31(4), 41-46.
- JALALEDDINE, S. M. S., HUTCHENS, C. G., STRATTAN, R. D., and COBERLY, W. A., 1990, ECG data compression techniques-a unified approach. IEEE Transactions on Biomedical Engineering, 37(4), 329-343.
- AHMED, N., MILNE, P. J., and HARRIS, S. G., 1975, Electrocardiographic data compression via orthogonal transforms. IEEE Transactions on Biomedical Engineering, 22, 484-487.
- DE FEREZ, T. A., STEFANELLI, M. C., and D'ALVANO, F., 1987, ECG data compression via exponential quantization of the Walsh spectrum. Journal of Clinical Engineering, 12(5), 373-378.
- TA, N. P., ATTIKIOUZEL, Y., and CREBBIN, G., 1990, Electrocardiogram compression using lapped orthogonal transform. Proceedings of Third Annual IEEE Symposium on Computer-Based Medical Systems (Los Alamitos, CA, USA: IEEE Computer Society Press), pp. 244-251.
- DEGANI, R., BORTOLAN, G, and MUROLO, R., 1991, Karhunen-Loeve coding of ECG signals. Proceedings of Computes in Cardiology (Los Alamitos, CA, USA: IEEE Computer Society Press), pp. 395-398.
- PHILIPS, W., and DE JONGHE, G., 1992, Data compression of ECG's by high-degree polynomial approximation. IEEE Transactions on Biomedical Engineering, 39(4), 330-337.
- CHEN, J., ITOH, S., and HASHIMOTO, T., 1993, ECG data compression by using wavelet transform. IEICE Transactions on Information and Systems, E76-D(12), 1454-1461.
- ANANDKUMAR,J.,and SZU,H., 1995,Compression of the electrocardiogram(ECG)using an adaptive orthonormal wavelet basis architecture. Proceedings of the SPIE-The International Society for Optical Engineering, 2491(2), 860-874.
- MORGAN,C. C., and SUFRIN, B. A., 1984, Specification of the Unix filing system. IEEE Transactions on Software Engineering, 10(2), 128-142.
- HAYES, I., 1987, Specification Case Studies (London: Prentice-Hall International).
- SPIVEY, J. M., 1988, The Z Notation: A Reference Manual (London: Prentice-Hall International).
- FURHT, B., and PEREZ, A., 1988, An adaptive real-time ECG compression algorithm with variable threshold. IEEE Transactions on Biomedical Engineering, 35(6), 489-494.
- PINCIROLI ,F.,and COMBI ,C., 1988,Compression of ECG signals in Holter Monitoring. Proceedings of the Twelfth Annual Symposium on Computer Applications in Medical Care (Washington, DC, USA : IEEE Computer Society Press), pp. 488-492.
- ZYWIETZ, C., JOSEPH, G., FISCHER, R., DEGANI, R., and WILLEMS, J. L., 1991, Compression and encoding of ECG data within the European Standard Communications Protocol. Proceedings of Computers in Cardiology (Los Alamitos, CA, USA : IEEE Computer Society Press), pp. 105-108.
- CERUITI, S., BIANCHI, A., BASELLI, G., CIVARDI, S., GUZZETTI, S., MALLIANI, A., PAGANI, A., and PAGANI , M , 1989, Compressed spectral arrays for the analysis of 24-hr heart rate variability signal : enhancement of parameters and data reduction. Computers and Biomedical Research, 22(5 ), 424-441.
- ISHIJIMA ,M.,1993,Fundamentals of the decision of optimum factors in the ECG data compression. IEICE Transactions on Information and Systems, E76-D(12), 1398-1403.
- BHARGAVA, V., WATANABE, K., and FROEUCHER, V. F., 1981, Progress in computer analysis of the exercise electrocardiogram. American Journal of Cardiology, 47(5), 1143-1151.
- MOODY, G. B., SOROUSHIAN, K., and MARK, R. G., 1988, ECG data compression for tapeless ambulatory monitors. Proceedings of Computers in Cardiology (Los Alamitos, CA, USA: IEEE Computer Society Press), pp. 467-470.
- CORMACK, G. V., and HORSPOOL, R. N., 1984, Algorithms for adaptive Huffman codes. Information Processing Letters, 18,159-165.
- TAKAHASHI, K., TAKEUCHI, S., and OHSAWA, N., 1993, Performance evaluation of ECG compression algorithms by reconstruction error and diagnostic response. IEICE Transactions on Information and Systems, E76-D(12), 1404-1410.
- BRADIE, B., 1995, Improved wavelet packet compression of electrocardiogram data, I: Noise filtering. Proceedings of the SPIE-The International Society for Optical Engineering, 2569(2), 778-789.
The formal specification of an electrocardiogram compressor
Reprints and Corporate Permissions
Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?
To request a reprint or corporate permissions for this article, please click on the relevant link below:
Academic Permissions
Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?
Obtain permissions instantly via Rightslink by clicking on the button below:
If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.
Related research
People also read lists articles that other readers of this article have read.
Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.
Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.