References
- Alexiades, G., Dhanasingh, A., Jolly, C. 2015. Method to estimate the complete and two-turn cochlear duct length. Otology & Neurotology, 36(5): 904–907. doi:https://doi.org/10.1097/mao.0000000000000620.
- Alnafjan, F.F., Allan, S.M., McMahon, C.M., da Cruz, M.J. 2018. Assessing cochlear length using cone beam computed tomography in adults with cochlear implants. Otology & Neurotology, 39(9): e757–e764. doi:https://doi.org/10.1097/mao.0000000000001934.
- Atturo, F., Barbara, M., Rask-Andersen, H. 2014. On the anatomy of the ‘hook’ region of the human cochlea and how it relates to cochlear implantation. Audiology & Neuro-otology, 19(6): 378–385. doi:https://doi.org/10.1159/000365585.
- Baranowski, T., Dobrovolskij, D., Dremel, K., Hölzing, A., Lohfink, G., Schladitz, K., Zabler, S. 2019. Local fiber orientation from X-ray region-of-interest computed tomography of large fiber reinforced composite components. Composites Science and Technology, 183: 107786. doi:https://doi.org/10.1016/j.compscitech.2019.107786.
- Boerckel, J.D., Mason, D.E., McDermott, A.M., Alsberg, E. 2014. Microcomputed tomography: approaches and applications in bioengineering. Stem Cell Research & Therapy, 5(6): 144. doi:https://doi.org/10.1186/scrt534.
- Boyer, E., Karkas, A., Attye, A., Lefournier, V., Escude, B., Schmerber, S. 2015. Scalar localization by cone-beam computed tomography of cochlear implant carriers: a comparative study between straight and periomodiolar precurved electrode arrays. Otology & Neurotology, 36(3): 422–429. doi:https://doi.org/10.1097/mao.0000000000000705.
- Braun, K., Böhnke, F., Stark, T. 2012. Three-dimensional representation of the human cochlea using micro-computed tomography data: presenting an anatomical model for further numerical calculations. Acta Oto-laryngologica, 132(6): 603–613. doi:https://doi.org/10.3109/00016489.2011.653670.
- Cicchetti, D. 1994. Guidelines, criteria, and rules of thumb for evaluating normed and standardized assessment instrument in psychology. Psychological Assessment, 6: 284–290. doi:https://doi.org/10.1037/1040-3590.6.4.284.
- Conte, G., Scola, E., Calloni, S., Brambilla, R., Campoleoni, M., Lombardi, L., et al. 2017. Flat panel angiography in the cross-sectional imaging of the temporal bone: assessment of image quality and radiation dose compared with a 64-section multisection CT scanner. AJNR. American Journal of Neuroradiology, 38(10): 1998–2002. doi:https://doi.org/10.3174/ajnr.A5302.
- Cornwall, H.L., Marway, P.S., Bance, M. 2021. A micro-computed tomography study of round window anatomy and implications for atraumatic cochlear implant insertion. Otology & Neurotology, 42(2): 327–334. doi:https://doi.org/10.1097/mao.0000000000002924.
- Dhanasingh, A. 2020. Research software in cochlear duct length estimation, Greenwood frequency mapping and CI electrode array length simulation. World Journal of Otorhinolaryngology – Head and Neck Surgery, doi:https://doi.org/10.1016/j.wjorl.2018.12.002.
- Dhanasingh, A., Jolly, C. 2017. An overview of cochlear implant electrode array designs. Hearing Research, 356: 93–103. doi:https://doi.org/10.1016/j.heares.2017.10.005.
- Erixon, E., Högstorp, H., Wadin, K., Rask-Andersen, H. 2009. Variational anatomy of the human cochlea: implications for cochlear implantation. Otology & Neurotology, 30(1): 14–22. doi:https://doi.org/10.1097/MAO.0b013e31818a08e8.
- Escudé, B., James, C., Deguine, O., Cochard, N., Eter, E., Fraysse, B. 2006. The size of the cochlea and predictions of insertion depth angles for cochlear implant electrodes. Audiology & Neuro-otology, 11(Suppl 1): 27–33. doi:https://doi.org/10.1159/000095611.
- Greenwood, D.D. 1961. Critical bandwidth and the frequency coordinates of the Basilar membrane. The Journal of the Acoustical Society of America, 33(10): 1344–1356. doi:https://doi.org/10.1121/1.1908437.
- Greenwood, D.D. 1990. A cochlear frequency-position function for several species--29 years later. Journal of the Acoustical Society of America, 87(6): 2592–2605. doi:https://doi.org/10.1121/1.399052.
- Güldner, C., Wiegand, S., Weiss, R., Bien, S., Sesterhenn, A., Teymoortash, A., Diogo, I. 2012. Artifacts of the electrode in cochlea implantation and limits in analysis of deep insertion in cone beam tomography (CBT). European Archives of Oto-rhino-laryngology, 269(3): 767–772. doi:https://doi.org/10.1007/s00405-011-1719-3.
- Gupta, R., Bartling, S.H., Basu, S.K., Ross, W.R., Becker, H., Pfoh, A., et al. 2004. Experimental flat-panel high-spatial-resolution volume CT of the temporal bone. AJNR. American Journal of Neuroradiology, 25(8): 1417–1424.
- Gupta, R., Cheung, A.C., Bartling, S.H., Lisauskas, J., Grasruck, M., Leidecker, C., et al. 2008. Flat-panel volume CT: fundamental principles, technology, and applications. Radiographics, 28(7): 2009–2022. doi:https://doi.org/10.1148/rg.287085004.
- Helpard, L., Li, H., Rask-Andersen, H., Ladak, H.M., Agrawal, S.K. 2020. Characterization of the human helicotrema: implications for cochlear duct length and frequency mapping. Journal of Otolaryngology – Head & Neck Surgery = Le Journal D'oto-rhino-laryngologie Et De Chirurgie Cervico-faciale, 49(1): 2. doi:https://doi.org/10.1186/s40463-019-0398-8.
- Iyaniwura, J.E., Elfarnawany, M., Ladak, H.M., Agrawal, S.K. 2018. An automated A-value measurement tool for accurate cochlear duct length estimation. Journal of Otolaryngology – Head & Neck Surgery = Le Journal D'oto-rhino-laryngologie Et De Chirurgie Cervico-faciale, 47(1): 5. doi:https://doi.org/10.1186/s40463-018-0253-3.
- Iyaniwura, J.E., Elfarnawany, M., Riyahi-Alam, S., Sharma, M., Kassam, Z., Bureau, Y., et al. 2017. Intra- and interobserver variability of cochlear length measurements in clinical CT. Otology & Neurotology, 38(6): 828–832. doi:https://doi.org/10.1097/mao.0000000000001411.
- Jiam, N.T., Gilbert, M., Cooke, D., Jiradejvong, P., Barrett, K., Caldwell, M., Limb, C.J. 2019. Association between flat-panel computed tomographic imaging-guided place-pitch mapping and speech and pitch perception in cochlear implant users. Jama Otolaryngology-- Head & Neck Surgery, 145(2): 109–116. doi:https://doi.org/10.1001/jamaoto.2018.3096.
- Jiam, N.T., Pearl, M.S., Carver, C., Limb, C.J. 2016. Flat-panel CT imaging for individualized pitch mapping in cochlear implant users. Otology & Neurotology, 37(6): 672–679. doi:https://doi.org/10.1097/mao.0000000000001060.
- Koch, R.W., Elfarnawany, M., Zhu, N., Ladak, H.M., Agrawal, S.K. 2017a. Evaluation of cochlear duct length computations using synchrotron radiation phase-contrast imaging. Otology & Neurotology, 38(6): e92–e99. doi:https://doi.org/10.1097/mao.0000000000001410.
- Koch, R.W., Ladak, H.M., Elfarnawany, M., Agrawal, S.K. 2017b. Measuring cochlear duct length – a historical analysis of methods and results. Journal of Otolaryngology – Head & Neck Surgery = Le Journal D'oto-rhino-laryngologie Et De Chirurgie Cervico-faciale, 46(1): 19. doi:https://doi.org/10.1186/s40463-017-0194-2.
- Koo, T.K., Li, M.Y. 2016. A guideline of selecting and reporting intraclass correlation coefficients for reliability research. Journal of Chiropractic Medicine, 15(2): 155–163. doi:https://doi.org/10.1016/j.jcm.2016.02.012.
- Landsberger, D.M., Svrakic, M., Roland, J.T., Jr., Svirsky, M. 2015. The relationship between insertion angles, default frequency allocations, and spiral ganglion place pitch in cochlear implants. Ear and Hearing, 36(5): e207–e213. doi:https://doi.org/10.1097/aud.0000000000000163.
- Lexow, G.J., Kluge, M., Gellrich, N.C., Lenarz, T., Majdani, O., Rau, T.S. 2018. On the accuracy of cochlear duct length measurement in computed tomographic images. European Archives of Oto-rhino-laryngology, 275(5): 1077–1085. doi:https://doi.org/10.1007/s00405-018-4930-7.
- Li, Z., Shi, D., Li, H., Tan, S., Liu, Y., Qi, C., Tang, A. 2018. Micro-CT study of the human cochlear aqueduct. Surgical and Radiologic Anatomy, 40(6): 713–720. doi:https://doi.org/10.1007/s00276-018-2020-6.
- Meng, J., Li, S., Zhang, F., Li, Q., Qin, Z. 2016. Cochlear size and shape variability and implications in cochlear implantation surgery. Otology & Neurotology, 37(9): 1307–1313. doi:https://doi.org/10.1097/mao.0000000000001189.
- Mertens, G., Van Rompaey, V., Van de Heyning, P., Gorris, E., Topsakal, V. 2020. Prediction of the cochlear implant electrode insertion depth: clinical applicability of two analytical cochlear models. Scientific Reports, 10(1): 3340. doi:https://doi.org/10.1038/s41598-020-58648-6.
- O'Connell, B.P., Hunter, J.B., Haynes, D.S., Holder, J.T., Dedmon, M.M., Noble, J.H., et al. 2017. Insertion depth impacts speech perception and hearing preservation for lateral wall electrodes. The Laryngoscope, 127(10): 2352–2357. doi:https://doi.org/10.1002/lary.26467.
- Pearl, M.S., Roy, A., Limb, C.J. 2014. High-resolution secondary reconstructions with the use of flat panel CT in the clinical assessment of patients with cochlear implants. AJNR. American Journal of Neuroradiology, 35(6): 1202–1208. doi:https://doi.org/10.3174/ajnr.A3814.
- Piergallini, L., Scola, E., Tuscano, B., Brambilla, R., Campoleoni, M., Raimondi, G., et al. 2018. Flat-panel CT versus 128-slice CT in temporal bone imaging: assessment of image quality and radiation dose. European Journal of Radiology, 106: 106–113. doi:https://doi.org/10.1016/j.ejrad.2018.07.013.
- Rak, K., Ilgen, L., Taeger, J., Schendzielorz, P., Voelker, J., Kaulitz, S., et al. 2020. Einfluss cochleärer Parameter auf die aktuelle Cochleaimplantatversorgung. Hno, doi:https://doi.org/10.1007/s00106-020-00968-0.
- Rotter, N., Schmitz, B., Sommer, F., Röhrer, S., Schuler, P.J., Bischof, F., et al. 2017. First use of flat-panel computed tomography during cochlear implant surgery: perspectives for the use of advanced therapies in cochlear implantation. Hno, 65(1): 61–65. doi:https://doi.org/10.1007/s00106-016-0213-z.
- Saeed, S.R., Selvadurai, D., Beale, T., Biggs, N., Murray, B., Gibson, P., et al. 2014. The use of cone-beam computed tomography to determine cochlear implant electrode position in human temporal bones. Otology & Neurotology, 35(8): 1338–1344. doi:https://doi.org/10.1097/mao.0000000000000295.
- Schatzer, R., Vermeire, K., Visser, D., Krenmayr, A., Kals, M., Voormolen, M., et al. 2014. Electric-acoustic pitch comparisons in single-sided-deaf cochlear implant users: frequency-place functions and rate pitch. Hearing Research, 309: 26–35. doi:https://doi.org/10.1016/j.heares.2013.11.003.
- Schendzielorz, P., Ilgen, L., Mueller-Graff, T., Noyalet, L., Völker, J., Taeger, J., et al. 2021. Precise evaluation of the cochlear Duct length by flat-panel volume computed tomography (fpVCT)-implication of secondary reconstructions. Otology & Neurotology, 42(3): e294–e303. doi:https://doi.org/10.1097/mao.0000000000002951.
- Schurzig, D., Timm, M.E., Batsoulis, C., John, S., Lenarz, T. 2018. Analysis of different approaches for clinical cochlear coverage evaluation after cochlear implantation. Otology & Neurotology, 39(8): e642–e650. doi:https://doi.org/10.1097/mao.0000000000001904.
- Schurzig, D., Timm, M.E., Batsoulis, C., Salcher, R., Sieber, D., Jolly, C., et al. 2018. A novel method for clinical cochlear Duct length estimation toward patient-specific cochlear implant selection. OTO Open, 2(4): 2473974x18800238. doi:https://doi.org/10.1177/2473974x18800238.
- Schurzig, D., Timm, M.E., Lexow, G.J., Majdani, O., Lenarz, T., Rau, T.S. 2018. Cochlear helix and duct length identification – evaluation of different curve fitting techniques. Cochlear Implants International, 19(5): 268–283. doi:https://doi.org/10.1080/14670100.2018.1460025.
- Sieber, D., Erfurt, P., John, S., Santos, G.R.D., Schurzig, D., Sørensen, M.S., Lenarz, T. 2019. The OpenEar library of 3D models of the human temporal bone based on computed tomography and micro-slicing. Scientific Data, 6(1): 180297. doi:https://doi.org/10.1038/sdata.2018.297.
- Struffert, T., Hertel, V., Kyriakou, Y., Krause, J., Engelhorn, T., Schick, B., et al. 2010. Imaging of cochlear implant electrode array with flat-detector CT and conventional multislice CT: comparison of image quality and radiation dose. Acta Oto-laryngologica, 130(4): 443–452. doi:https://doi.org/10.3109/00016480903292700.
- Timm, M.E., Majdani, O., Weller, T., Windeler, M., Lenarz, T., Büchner, A., Salcher, R.B. 2018. Patient specific selection of lateral wall cochlear implant electrodes based on anatomical indication ranges. PLoS One, 13(10): e0206435. doi:https://doi.org/10.1371/journal.pone.0206435.
- Verbist, B.M., Skinner, M.W., Cohen, L.T., Leake, P.A., James, C., Boëx, C., et al. 2010. Consensus panel on a cochlear coordinate system applicable in histologic, physiologic, and radiologic studies of the human cochlea. Otology & Neurotology, 31(5): 722–730. doi:https://doi.org/10.1097/MAO.0b013e3181d279e0.
- Wirtz, M. 2004. Determining the quality of rater judgements using intraclass correlation, and enhancing rater judgements. Rehabilitation (Stuttg), 43(6): 384–389. doi:https://doi.org/10.1055/s-2003-814935.
- Wuerfel, W., Burke, W., Lenarz, T., Kraemer, R. 2015. Cochlear length determination in temporal bone specimens using histological serial-micro grinding imaging, micro computed tomography and flat-panel volumetric com-puted tomography. Otolaryngology Online Journal, 5: 39–59.
- Würfel, W., Lanfermann, H., Lenarz, T., Majdani, O. 2014. Cochlear length determination using cone beam computed tomography in a clinical setting. Hearing Research, 316: 65–72. doi:https://doi.org/10.1016/j.heares.2014.07.013.
- Xu, J., Xu, S.A., Cohen, L.T., Clark, G.M. 2000. Cochlear view: postoperative radiography for cochlear implantation. The American Journal of Otology, 21(1): 49–56.