1,751
Views
154
CrossRef citations to date
0
Altmetric
Original papers

5-year experience of highly cross-linked polyethylene in cemented and uncemented sockets: Two randomized studies using radiostereometric analysis

, , &
Pages 746-754 | Received 24 Jan 2007, Accepted 19 Apr 2007, Published online: 08 Jul 2009

  • Bragdon C R, Thanner J, Greene ME, Malchau H, Digas G, Harris W H, Karrholm J. Standing versus supine radiographs in RSA evaluation of femoral head penetration. Clin Orthop 2006, 448: 46–51
  • D'Antonio J A, Manley M T, Capello W N, Bierbaum B E, Ramakrishnan R, Naughton M, Sutton K. Five-year experience with crossfire highly cross-linked polyethylene. Clin Orthop 2005, 441: 143–50
  • Digas G, Kärrholm J, Thanner J, Malchau H, Herberts P. Highly cross-linked polyethylene in cemented THA: Randomized study of 61 hips. Clin Orthop 2003, 417: 126–38
  • Digas G, Kärrholm J, Thanner J, Malchau H, Herberts P. Highly cross-linked polyethylene in total hip arthroplasty. Randomised evaluation of penetration rate in cemented and uncemented sockets using radiostereometric analysis. Clin Orthop 2004, 429: 6–16
  • Dorr L D, Wan Z, Shahrdar C, Sirianni L, Boutary M, Yun A. Clinical performance of a durasul highly cross-linked polyethylene acetabular liner for total hip arthroplasty at ifve years. J.Bone joint Surg (Am) 2005; 87: 1816–21
  • Dumbleton J H, Manley M T, Edidin A A. A literature review of the association between wear rate and osteolysis in total hip arthroplasty. J Arthroplasty 2002; 17: 649–61
  • Engh C A, Jr, Stepniewski A S, Ginn S D, Beykirch S E, Sychterz-Terefenko C J, Hopper R H, Jr, Engh C A. A randomized prospective evaluation of outcomes after total hip arthroplasty using cross-linked marathon and non-cross-linked Enduron polyethylene liners. J Arthroplasty 2006; 21: 17–25
  • Han C D, Choe W S, Yoo J H. Effect of polyethylene wear on osteolysis in cementless primary total hip arthroplasty: minimal 5-year follow-up study. J Arthroplasty 1999; 14: 714–23
  • Harris W H. Wear and periprosthetic osteolysis: the problem. Clin Orthop 2001, 393: 66–70
  • Heisel C, Silva M, dela Rosa M A, Schmalzried T P. Shortterm in vivo wear of cross-linked polyethylene. J Bone Joint Surg (Am) 2004; 86: 748–51
  • Hopper R H, Jr, Young A M, Orishimo K F, McAuley J P. Correlation between early and late wear rates in total hip arthroplasty with application to the performance of marathon cross-linked polyethylene liners. J Arthroplasty 2003; 18: 60–7
  • Jasty M, Goetz D D, Bragdon C R, Lee K R, Hanson A E, Elder J R, Harris W H. Wear of polyethylene acetabular components in total hip arthroplasty. Ananalysis of one hundred and twenty-eight components retrieved at autopsy or revision operations. J Bone Joint Surg (Am) 1997; 79: 349–58
  • Kärrholm J, Herberts P, Hultmark P, Malchau H, Nivbrant B, Thanner J. Radiostereometry of hip prostheses. Review of methodology and clinical results. Clin Orthop 1997, 344: 94–110
  • Manning D W, Chiang P P, Martell J M, Galante J O, Harris W H. In vivo comparative wear study of traditional and highly cross-linked polyethylene in total hip arthroplasty. J Arthroplasty 2005; 20: 880–6
  • Martell J M, Verner J J, Incavo S J. Clinical performance of a highly cross-linked polyethylene at two years in total hip arthroplasty: a randomized prospective trial. J Arthroplasty 2003; 18: 55–9
  • McKellop H, Shen F W, Lu B, Campbell P, Salovey R. Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements. J Orthop Res 1999; 17: 157–67
  • Muratoglu O K, Bragdon C R, O'Connor D O, Jasty M, Harris W H. A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties. J Arthroplasty 2001; 16: 149–60
  • Orishimo K F, Claus A M, Sychterz C J, Engh C A. Relationship between polyethylene wear and osteolysis in hips with a second-generation porous-coated cementless cup after seven years of follow-up. J Bone Joint Surg (Am) 2003; 85: 1095–9
  • Röhrl S, Nivbrant B, Mingguo L, Hewitt B. In vivo wear and migration of highly cross-linked polyethylene cups a radiostereometry analysis study. J Arthroplasty 2005; 20: 409–13
  • Selvik G. Roentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal system. Acta Orthop Scand 1989, Suppl 232: 1–51
  • Sychterz C J, Young A M, McAuley J P, Engh C A. Comparison of head penetration into Hylamer and Enduron polyethylene liners: a follow-up report. J Arthroplasty 2000; 15: 372–4
  • Söderkvist I, Wedin P A. Determining the movements of the skeleton using well configured markers. J Biomech 1993; 26: 1473–7
  • Von Schewelov T, Onsten I, Markusson P, Carlsson A. Weight bearing radiographs are not necessary for measurement of polyethylene penetration in total hip prostheses: a radiostereometric study of 111 patients examined in weight-bearing and supine position. Acta Orthop 2006; 77: 104–8
  • Wilkinson J M, Hamer A J, Stockley I, Eastell R. Polyethylene wear rate and osteolysis: critical threshold versus continuous dose-response relationship. J Orthop Res 2005; 23: 520–5

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.