- Aro H T, Alm J J, Moritz N, Mäkinen T J, Lankinen P. Low BMD affects initial stability and delays stem osseointegration in cementless total hip arthroplasty in women. Acta Orthop 2012; 83(2): 107–14.
- Callary S A, Campbell D G, Mercer G E, Nilsson K G, Field J R. The 6-year migration characteristics of a hydroxyapatite-coated femoral stem. A radiostereometric analysis study. J Arthroplasty 2012; 27(7): 1344–8.
- Casper D S, Kim G K, Parvizi J, Freeman T A. Morphology of the proximal femur differs widely with age and sex: relevance to design and selection of femoral prostheses. J Orthop Res 2012; 30(7): 1162–6.
- Catanach M J M, Sorial R M, Eslick G D. Thirteen-year outcomes in the anatomique Benoist Girard II hip prosthesis. ANZ J Surg 2015; 85(4): 255–9.
- Derbyshire B, Prescott R J, Porter M L. Notes on the use and interpretation of radiostereometric analysis. Acta Orthop 2009; 80(1): 124–30.
- Engh C A, Massin P, Suthers K E. Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components. Clin Orthop Relat Res 1990; 257: 107–28.
- Epinette J A, Asencio G, Essig J, Llagonne B, Nourissat C. Clinical results, radiological findings and survival of a proximally hydroxyapatite-coated hip ABG II stem at a minimum of ten years’ follow-up: results of a consecutive multicentre study of 1148 hips in 1053 patients. Bone Joint J 2013; 95-B(12): 1610–16.
- Finnish Arthroplasty Register (FAR). Endonet Report 2018. Available from: https://www2.thl.fi/endo/report/#index
- Finnilä S, Moritz N, Svedström E, Alm J J, Aro H T. Increased migration of uncemented acetabular cups in female total hip arthroplasty patients with low systemic bone mineral density. Acta Orthop 2016; 87(1): 48–54.
- Giebaly D E, Twaij H, Ibrahim M, Haddad F S. Cementless hip implants: an expanding choice. Hip Int 2016; 26(5): 413–23.
- Glowacki J, Hurwitz S, Thornhill T S, Kelly M, LeBoff M S. Osteoporosis and vitamin-D deficiency among postmenopausal women with osteoarthritis undergoing total hip arthroplasty. J Bone Joint Surg 2003; 85-A(12): 2371–7.
- Herrera A, Mateo J, Lobo-Escolar A, Panisello J J, Ibarz E, Gracia L. Long-term outcomes of a new model of anatomical hydroxyapatite-coated hip prosthesis. J Arthroplasty 2013; 28(7): 1160–6.
- Khanuja H S, Vakil J J, Goddard M S, Mont M A. Cementless femoral fixation in total hip arthroplasty. J Bone Joint Surg Am 2011; 93(5): 500–9.
- Kärrholm J. Radiostereometric analysis of early implant migration: a valuable tool to ensure proper introduction of new implants. Acta Orthop 2012; 83(6): 551–2.
- Kärrholm J, Herberts P, Hultmark P, Malchau H, Nivbrant B, Thanner J. Radiostereometry of hip prostheses: review of methodology and clinical results. Clin Orthop Relat Res 1997; (344): 94-110.
- Mäkelä K T, Eskelinen A, Paavolainen P, Pulkkinen P, Remes V. Cementless total hip arthroplasty for primary osteoarthritis in patients aged 55 years and older. Acta Orthop 2010; 81(1): 42–52.
- Mäkinen T J, Koort J K, Mattila K T, Aro H T. Precision measurements of the RSA method using a phantom model of hip prosthesis. J Biomech 2004; 37(4): 487–93.
- Mäkinen T J, Alm JJ, Laine H, Svedström E, Aro H T. The incidence of osteopenia and osteoporosis in women with hip osteoarthritis scheduled for cementless total joint replacement. Bone 2007; 40(4): 1041–7.
- Nazari-Farsani S, Finnilä S, Moritz N, Mattila K, Alm J J, Aro H T. Is model-based radiostereometric analysis suitable for clinical trials of a cementless tapered wedge femoral stem? Clin Orthop Relat Res 2016; 474(10): 2246–53.
- Noble P C, Box G G, Kamaric E, Fink M J, Alexander J W, Tullos H S. The effect of aging on the shape of the proximal femur. Clin Orthop Relat Res 1995; 316: 31–44.
- Nysted M, Foss O A, Klaksvik J, Benum P, Haugan K, Husby O S, Aamodt A. Small and similar amounts of micromotion in an anatomical stem and a customized cementless femoral stem in regular-shaped femurs. Acta Orthop 2014; 85(2): 152–8.
- Poolman R W, Verhaar J A N, Schreurs B W, Bom L P A, Nelissen R G H H, Koot H W J, Goosen J H M, Verheyen C C P M. Finding the right hip implant for patient and surgeon: the Dutch strategy—empowering patients. Hip Int 2015; 25(2): 131–7.
- Ranstam J, Ryd L, Onsten I. Accurate accuracy assessment: review of basic principles. Acta Orthop Scand 2000; 71(1): 106–8.
- Ryd L. The Gothenburg osseointegrated titanium (GOT) hip - a new addition to the orthopedic arsenal - whether osseointegrated or not. Acta Orthop 2006; 77(4): 547–8.
- Van Rietbergen B, Huiskes R. Load transfer and stress shielding of the hydroxyapatite-ABG hip: a study of stem length and proximal fixation. J Arthroplasty 2001; 16(8 Suppl. 1): 55–63.
- Sköldenberg O G, Salemyr M, Bodén H S, Lundberg A, Ahl T E, Adolphson P Y. A new uncemented hydroxyapatite-coated femoral component for the treatment of femoral neck fractures: two-year radiostereometric and bone densitometric evaluation in 50 hips. Bone Joint J 2011; 93-B(5): 665–77.
- SooHoo N F, Vyas R M, Samimi D B, Molina R, Lieberman J R. Comparison of the responsiveness of the SF-36 and WOMAC in patients undergoing total hip arthroplasty. J Arthroplasty 2007; 22(8): 1168–73.
- Thien T M, Ahnfelt L, Eriksson M, Strömberg C, Kärrholm J. Immediate weight bearing after uncemented total hip arthroplasty with an anteverted stem: a prospective randomized comparison using radiostereometry. Acta Orthop 2007; 78(6): 730–8.
- Thien T M, Chatziagorou G, Garellick G, Furnes O, Havelin L I, Mäkelä K, Overgaard S, Pedersen A, Eskelinen A, Pulkkinen P, Kärrholm J. Periprosthetic femoral fracture within two years after total hip replacement: analysis of 437,629 operations in the Nordic Arthroplasty Register Association database. J Bone Joint Surg Am 2014; 96(19): e167.
- Tonino A J, Van Der Wal B C H, Heyligers I C, Grimm B. Bone remodeling and hydroxyapatite resorption in coated primary hip prostheses. Clin Orthop Relat Res 2009; 467(2): 478–84.
- Valstar E R, Gill R, Ryd L, Flivik G, Börlin N, Kärrholm J. Guidelines for standardization of radiostereometry (RSA) of implants. Acta Orthop 2005; 76(4): 563–72.
- Van Der Wal B C H, Rahmy A, Grimm B, Heyligers I, Tonino A. Preoperative bone quality as a factor in dual-energy X-ray absorptiometry analysis comparing bone remodelling between two implant types. Int Orthop 2008; 32(1):3 9–45.
- Weber E, Sundberg M, Flivik G. Design modifications of the uncemented Furlong hip stem result in minor early subsidence but do not affect further stability: a randomized controlled RSA study with 5-year follow-up. Acta Orthop 2014; 85(6): 556–61.
- White C A, Carsen S, Rasuli K, Feibel R J, Kim P R, Beaulé P E. High incidence of migration with poor initial fixation of the Accolade stem. Clin Orthop Relat Res 2012; 470(2): 410–17.
- Wolf O, Mattsson P, Milbrink J, Larsson S, Mallmin H. Periprosthetic bone mineral density and fixation of the uncemented CLS stem related to different weight bearing regimes: a randomized study using DXA and RSA in 38 patients followed for 5 years. Acta Orthop 2010; 81(3): 286–91.
- Zebaze R M, Ghasem-Zadeh A, Bohte A, Iuliano-Burns S. Intracortical remodelling and porosity in the distal radius and post-mortem femurs of women: a cross sectional study. Lancet 2010; 375: 1729–36.
Acta Orthopaedica
Volume 89, 2018 - Issue 5
Open access
1,291
Views
16
CrossRef citations to date
0
Altmetric
Articles
Good stability of a cementless, anatomically designed femoral stem in aging women: a 9-year RSA study of 32 patients
Erik AroDepartment of Orthopaedic Surgery and Traumatology, Turku University Hospital and University of Turku, Turku;
, Jessica J AlmDepartment of Orthopaedic Surgery and Traumatology, Turku University Hospital and University of Turku, Turku;
, Niko MoritzDepartment of Orthopaedic Surgery and Traumatology, Turku University Hospital and University of Turku, Turku;
, Kimmo MattilaDepartment of Diagnostic Imaging, Turku University Hospital, Turku, Finland
& Hannu T AroDepartment of Orthopaedic Surgery and Traumatology, Turku University Hospital and University of Turku, Turku; Correspondence[email protected]
Pages 490-495
|
Published online: 10 Jul 2018
Related research
People also read lists articles that other readers of this article have read.
Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.
Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.