36
Views
0
CrossRef citations to date
0
Altmetric
Key Paper Evaluation

Individualizing hemodynamic optimization during the management of circulatory collapse

, &
Pages 1217-1220 | Published online: 10 Jan 2014

References

  • Vincent JL, Gerlach H. Fluid resuscitation in severe sepsis and septic shock: an evidence-based review. Crit. Care Med. 32(Suppl. 11), S451–S454 (2004).
  • Shoemaker WC, Appel PL, Kram HB, Waxman K, Lee TS. Prospective trial of supranormal values of survivors as therapeutic goals in high-risk surgical patients. Chest 94(6), 1176–1186 (1988).
  • Sakr Y, Vincent JL, Reinhart K et al.; Sepsis Occurence in Acutely Ill Patients Investigators. High tidal volume and positive fluid balance are associated with worse outcome in acute lung injury. Chest 128(5), 3098–3108 (2005).
  • National Heart, Lung, Blood Institute Acute Respiratory Distress Syndrome Clinical Trials Network; Wiedemann HP, Wheeler AP, Bernard GR et al. Comparison of two fluid-management strategies in acute lung injury. N. Engl. J. Med. 354(24), 2564–2575 (2006).
  • Mitchell JP, Schuller D, Calandrino FS, Schuster DP. Improved outcome based on fluid management in critically ill patients requiring pulmonary artery catheterization. Am. Rev. Respir. Dis. 145(5), 990–998 (1992).
  • Pinsky MR. Pulmonary artery occlusion pressure. Intensive Care Med. 29(1), 19–22 (2003).
  • Michard F, Alaya S, Zarka V, Bahloul M, Richard C, Teboul JL. Global end-diastolic volume as an indicator of cardiac preload in patients with septic shock. Chest 124(5), 1900–1908 (2003).
  • Sevransky JE, Nour S, Susla GM, Needham DM, Hollenberg S, Pronovost P. Hemodynamic goals in randomized clinical trials in patients with sepsis: a systematic review of the literature. Crit. Care 11(3), R67 (2007).
  • Uchino S, Bellomo R, Morimatsu H et al.; PAC/PiCCO Use and Likelihood of Success Evaluation [PULSE] Study Group. Pulmonary artery catheter versus pulse contour analysis: a prospective epidemiological study. Crit. Care 10(6), R174 (2006).
  • Trof RJ, Beishuizen A, Cornet AD, de Wit RJ, Girbes AR, Groeneveld AB. Volume-limited versus pressure-limited hemodynamic management in septic and nonseptic shock. Crit. Care Med. 40(4), 1177–1185 (2012).
  • Goepfert MS, Reuter DA, Akyol D, Lamm P, Kilger E, Goetz AE. Goal-directed fluid management reduces vasopressor and catecholamine use in cardiac surgery patients. Intensive Care Med. 33(1), 96–103 (2007).
  • Vincent JL, Sakr Y, Sprung CL et al.; Sepsis Occurrence in Acutely Ill Patients Investigators. Sepsis in European intensive care units: results of the SOAP study. Crit. Care Med. 34(2), 344–353 (2006).
  • Dellinger RP, Levy MM, Carlet JM et al.; International Surviving Sepsis Campaign Guidelines Committee; American Association of Critical-Care Nurses; American College of Chest Physicians; American College of Emergency Physicians; Canadian Critical Care Society; European Society of Clinical Microbiology and Infectious Diseases; European Society of Intensive Care Medicine; European Respiratory Society; International Sepsis Forum; Japanese Association for Acute Medicine; Japanese Society of Intensive Care Medicine; Society of Critical Care Medicine; Society of Hospital Medicine; Surgical Infection Society; World Federation of Societies of Intensive and Critical Care Medicine. Surviving Sepsis Campaign: international guidelines for management of severe sepsis and septic shock: 2008. Crit. Care Med. 36(1), 296–327 (2008).
  • Jones AE, Shapiro NI, Trzeciak S, Arnold RC, Claremont HA, Kline JA; Emergency Medicine Shock Research Network (EMShockNet) Investigators. Lactate clearance vs central venous oxygen saturation as goals of early sepsis therapy: a randomized clinical trial. JAMA 303(8), 739–746 (2010).
  • Chawla LS, Zia H, Gutierrez G, Katz NM, Seneff MG, Shah M. Lack of equivalence between central and mixed venous oxygen saturation. Chest 126(6), 1891–1896 (2004).
  • Hofer CK, Furrer L, Matter-Ensner S et al. Volumetric preload measurement by thermodilution: a comparison with transoesophageal echocardiography. Br. J. Anaesth. 94(6), 748–755 (2005).
  • Goedje O, Seebauer T, Peyerl M, Pfeiffer UJ, Reichart B. Hemodynamic monitoring by double-indicator dilution technique in patients after orthotopic heart transplantation. Chest 118(3), 775–781 (2000).
  • Connors AF Jr, Speroff T, Dawson NV et al. The effectiveness of right heart catheterization in the initial care of critically ill patients. SUPPORT Investigators. JAMA 276(11), 889–897 (1996).
  • MacKirdy FN, Livingston BM, Howie JC. The relationship between the presence of pulmonary artery catheters and case-mix adjusted outcome of patients admitted to Scottish Intensive Care units. Clin. Intensive Care 8, 97 (1997).
  • Rhodes A, Cusack RJ, Newman PJ, Grounds RM, Bennett ED. A randomised, controlled trial of the pulmonary artery catheter in critically ill patients. Intensive Care Med. 28(3), 256–264 (2002).
  • Richard C, Warszawski J, Anguel N et al.; French Pulmonary Artery Catheter Study Group. Early use of the pulmonary artery catheter and outcomes in patients with shock and acute respiratory distress syndrome: a randomized controlled trial. JAMA 290(20), 2713–2720 (2003).
  • Harvey S, Harrison DA, Singer M et al.; PAC-Man study collaboration. Assessment of the clinical effectiveness of pulmonary artery catheters in management of patients in intensive care (PAC-Man): a randomised controlled trial. Lancet 366(9484), 472–477 (2005).
  • Osman D, Ridel C, Ray P et al. Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge. Crit. Care Med. 35(1), 64–68 (2007).
  • Koo KK, Sun JC, Zhou Q et al. Pulmonary artery catheters: evolving rates and reasons for use. Crit. Care Med. 39(7), 1613–1618 (2011).
  • Ospina-Tascón GA, Cordioli RL, Vincent JL. What type of monitoring has been shown to improve outcomes in acutely ill patients? Intensive Care Med. 34(5), 800–820 (2008).
  • Michard F, Boussat S, Chemla D et al. Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure. Am. J. Respir. Crit. Care Med. 162(1), 134–138 (2000).
  • Marx G, Cope T, McCrossan L et al. Assessing fluid responsiveness by stroke volume variation in mechanically ventilated patients with severe sepsis. Eur. J. Anaesthesiol. 21(2), 132–138 (2004).
  • Takala J. Hemodynamic support: focus on monitoring tools or treatments? Crit. Care Med. 40(4), 1359–1360 (2012).

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.