1,116
Views
1
CrossRef citations to date
0
Altmetric
Clinical Study

Bioimpedance spectroscopy for the differential diagnosis of hyponatremia

, , , , , , , , , & show all
Pages 947-950 | Received 14 Nov 2014, Accepted 20 Mar 2015, Published online: 27 Apr 2015

References

  • Elhassan EA, Schrier RW. Disorders of extracellular volume. In: Floege J, Johnson RJ, Feehally J, eds. Comprehensive Clinical Nephrology. 4th ed. St. Louis: Elsevier Saunders; 2010:85–99
  • Upadhyay A, Jaber BL, Madias NE. Incidence and prevalence of hyponatremia. Am J Med. 2006;119(7 Suppl. 1):S30–S35
  • Forster HP, Emanuel E, Grady C. The 2000 revision of the Declaration of Helsinki: A step forward or more confusion? Lancet. 2001;358(9291):1449–1453
  • Schiller NB, Shah PM, Crawford M, et al. Recommendations for quantification of left ventricle by two-dimensional echocardiography. American Society of Echocardiography Committee on Standards, Subcommittee on Quatification of Two-Dimensional Echocardiograms. J Am Soc Echocardiogr. 1989;2:358–367
  • Feigenbaum H, Armstrong WF, Ryan T. Evaluation of systolic and diastolic function of the left ventricle. In: Feigenbaum H, ed. Feigenbaum’s Echocardiography. 6th ed. Hagerstown, USA: Lippincott Williams and Wilkins; 2005:142–145
  • Moissl UM, Wabel P, Chamney PW, et al. Body fluid volume determination via body composition spectroscopy in health and disease. Physiol Meas. 2006;27(9):921–933
  • Wabel P, Chamney P, Moissl U, Jirka T. Importance of whole-body bioimpedance spectroscopy for the management of fluid balance. Blood Purif. 2009;27(1):75–80
  • Chamney PW, Wabel P, Moissl UM, et al. A whole-body model to distinguish excess fluid from the hydration of major body tissues. Am J Clin Nutr. 2007;85(1):80–89
  • Cohen J. A coefficient of agreement for nominal scales. Educ Psychol Meas. 1960;20:37–46
  • Goh KP. Management of hyponatremia. Am Fam Physician. 2004;69(10):2387–2394
  • Hoffer EC, Meador CK, Simpson DC. Correlation of whole-body impedance with total body water volume. J Appl Physiol. 1969;27:531–534
  • Lukaski HC, Johnson PE, Bolonchuk WW, Lykken GI. Assessment of fat-free mass using bioelectrical impedance measurements of the human body. Am J Clin Nutr. 1985;41:810–817
  • Spiegel DM, Bashir K, Fisch B. Bioimpedance resistance ratios for the evaluation of dry weight in hemodialysis. Clin Nephrol. 2000;53:108–114
  • Zhu F, Kuhlmann MK, Sarkar S, et al. Adjustment of dry weight in hemodialysis patients using intradialytic continuous multifrequency bioimpedance of the calf. Int J Artif Organs. 2004;27:104–109
  • Chamney PW, Kramer M, Rode C, Kleinekofort W, Wizemann V. A new technique for establishing dry weight in hemodialysis patients via whole body bio-impedance. Kidney Int. 2002;61:2250–2258
  • Chertow GM, Lazarus JM, Lew NL, Ma L, Lowrie EG. Development of a population specific regression equation to estimate total body water in hemodialysis patients. Kidney Int. 1997;51:1578–1582
  • Chertow GM, Lowrie EG, Wilmore DW, et al. Nutritional assessment with bioelectrical impe-dance analysis in maintenance hemodialysis patients. J Am Soc Nephrol. 1995;6:75–81
  • Ikizler TA, Wingard RL, Harvell J, Shyr Y, Hakum RM. Association of morbidity with markers of nutrition and inflammation in chronic hemodialysis patients: A prospective study. Kidney Int. 1999;55:1945–1951
  • Hur E, Yildiz G, Budak Kose S, et al. Bioimpedance and echocardiography used interchangeably in volume comparison of dialysis patients. Hippokratia. 2012;16(4):329–334
  • Hur E, Gungor O, Musayev O, et al. Bioimpedance spectroscopy for the detection of hypervolemia in peritoneal dialysis patients. Adv Perit Dial. 2011;27:65–70
  • Hur E, Usta M, Toz H, et al. Effect of fluid management guided by bioimpedance spectroscopy on cardiovascular parameters in hemodialysis patients: A randomized controlled trial. Am J Kidney Dis. 2013;61(6):957–965
  • Hür E, Özişik M, Ural C, et al. Hypervolemia for hypertension pathophysiology: A population-based study. Biomed Res Int. 2014;2014:895401
  • Sipahi S, Hur E, Demirtas S, et al. Body composition monitor measurement technique for the detection of volume status in peritoneal dialysis patients: The effect of abdominal fullness. Int Urol Nephrol. 2011;43(4):1195–1199
  • Kose SB, Hür E, Taskin H, Bicak S, Duman S. Volume status effected by gravity and body fluid shifts: New protocol for bioimpedance measurements. Ren Fail. 2014;36(10):1587–1588
  • Kim JS, Lee JY, Park H, Han BG, Choi SO, Yang JW. Estimation of body fluid volume by bioimpedance spectroscopy in patients with hyponatremia. Yonsei Med J. 2014;55(2):482–486

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.