71
Views
14
CrossRef citations to date
0
Altmetric
Research Article

Mass Spectrometry of Trace Elements in Biological Samples

, , , &
Pages 35-87 | Published online: 27 Sep 2008

References

  • Savory J., Wills M. R. Trace metals: essential nutrients or toxins. Clin Chem 1992; 38: 1565–73
  • Elinder C-G, Gerhardsson L., Oberdoerster G. Biological monitoring of toxic metals – overview. Biological monitoring of toxic metals', T. W. Clarkson, L. Friberg, G. F. Nordberg, P. R. Sager. Plenum Press, New York 1988; 1–71
  • O'Dell B. L. Bioavailability of trace elements. Nutr Rev 1984; 42: 301–08
  • Nielsen F. H. Possible future implications of ultratrace elements in human health and disease. Essential and toxic trace elements in human health and disease. Alan R. Liss, New York 1988; 272–92
  • Nielsen F. H. New essential trace elements for the life sciences. Biol Trace Elem Res 1990; 599–611
  • Nielsen F. H. Trace and ultratrace elements in health and disease. Compr Ther 1991; 17: 20–26
  • Imura N., Naganuma A., Satoh M., Chen I. T. Trace elements as useful tool for cancer chemotherapy. Essential and toxic trace elements in human health and disease. Alan R. Liss, New York 1988; 443–56
  • Weaver C. M. Assessing calcium status and metabolism. J Nutr 1990; 120: 1470–73
  • King J. C. Assessment of zinc status. J Nutr 1990; 120: 1474–79
  • Johnson M. A. Iron: nutrition monitoring and nutrition status assessment. J Nutr 1990; 120: 1486–91
  • Iyengar V., Woittiez J. Trace elements in human clinical specimens: evaluation of literature data to identify reference values. Clin Chem 1988; 34: 474–81
  • Wolf W. R. Accuracy in trace element analysis. Essential and toxic trace elements in human health and disease. Alan R. Liss, New York 1988; 533–44
  • Comelis R. A journey through the hazards of possible errors in the analysis of trace elements in body fluids and tissues. Mikrochim Acta 1991; 3: 37–44
  • Savory J., Wills M. R. Advances in the detection of trace elements in biological fluids and tissues. Trace elements in health and disease, A. Aitio, A. Aro, J. Jarvisalo, H. Vainio. Royal Society of Chemistry, Cambridge 1991; 3–17
  • Shamberger R. J. Trace metal analysis. Cancer Invest 1985; 3: 271–83
  • Veillon C., Alvarez R. Determination of trace metals in biological materials by stable isotope dilution. Metal ions in biological systems, H. Sigel. Marcel Dekker., New York 1983; Vol 16: 103–22
  • Dulka J. J., Risby T. H. Ultratrace metals in some environmental and biological systems. Anal Chem 1976; 48: 640A–53A
  • Schroeder H. A., Nason A. P. Trace element analysis in clinical chemistry. Clin Chem 1971; 17: 461–74
  • Versieck J., Vanballenberghe L., Wittoek A., Vermeir G., Vandecasteele C. Determination of mercury in human serum and packed blood cells by neutron activation analysis. Biol Trace Elem Res 1990; 683–89
  • Versieck J., Vanballenberghe L. Determination of tin in human blood serum by radiochemical neutron activation analysis. Anal Chem 1991; 63: 1143–46
  • Subramanian K. S. Determination of trace metals in human blood by graphite furnace atomic absorption spectrometry. Prog Anal Spectrosc 1986; 9: 237–334
  • Subramanian K. S. Determination of trace elements in biological fluids other than blood by graphite furnace atomic absorption spectrometry. Prog Anal Spectrosc 1988; 11: 511–608
  • Johnson P. E. Methodology for stable isotope analysis in biological materials (a review). J Micronutr Anal 1989; 6: 59–83
  • Heumann K. G. Mass spectrometric element analysis – advances and new perspectives in a modern analytic method. Comments Inorg Chem 1987; 6: 145–73
  • Fassett J. D., Paulsen P. J. Isotope dilution mass spectrometry for accurate elemental analysis. Anal Chem 1989; 61: 643A–9A
  • Heumann K. G. Isotope dilution mass spectrometry (IDMS) of the elements. Mass Spectrom Rev 1992; 11: 41–67
  • Moore L. J., Machlan L. A. High accuracy determination of calcium in blood serum by isotope dilution mass spectrometry. Anal Chem 1972; 44: 2291–95
  • VanderMerwe D. G., Sellschop JPF, Erasmus C. S., Pettifor J. M. A stable tracer technique for calcium metabolism studies. J Trace Elem Electrolytes Health Dis 1988; 2: 209–14
  • Janghorbani M., Young V. R. Use of stable isotopes to determine bioavailability of minerals in human diets using the method of fecal monitoring. Am J Clin Nutr 1980; 33: 2021–30
  • Janghorbani M., Young V. R. Stable isotope methods for bioavailability assessment of dietary minerals in humans. Advances in nutrition research, H. H. Draper. Plenum Press, New York 1980; Vol. 3: 127–55
  • Hachey D. L., Wong W. W., Boutton T. W., Klein P. D. Isotope ratio measurements in nutrition and biomedical research. Mass Spectrom Rev 1987; 6: 289–328
  • Janghorbani M., Ting BTG, Zesel S. H. Trace elements research with stable isotope tracers. Essential and toxic trace elements in human health and disease. Alan R Liss, New York 1988; 545–56
  • Tumlund J. R. The use of stable isotopes in mineral nutrition research. J Nutr 1989; 119: 7–14
  • Janghorbani M., Ting BTG. Stable isotope methods for studies of mineral/trace element metabolism. J Nutr Biochem 1990; 1: 4–19
  • Rabinowitz M. B., Wetherill G. W., Kopple J. D. Lead metabolism in normal human: stable isotope studies. Science 1973; 182: 725–27
  • Rabinowitz M. B. Stable isotope mass spectrometry in childhood lead poisoning. Biol Trace Elem Res 1987; 12: 223–29
  • Tumlund J. R., Michel M. C., Keyes W. R., King J. C., Margen S. Use of enriched stable isotopes to determine zinc and iron absorption in elderly men. Am J Clin Nutr 1982; 35: 1033–40
  • Tumlund J. R., Michel M. C., Keyes W. R., Schutz Y., Margen S. Copper absorption in elderly men determined by using stable 65Cu. Am J Clin Nutr 1982; 36: 587–91
  • Tumlund J. R. Use of stable isotopes to determine bioavailability of trace elements in humans. Sci Total Environ 1983; 28: 385–92
  • Swanson C. A., Tumlund J. R., King J. C. Effect of dietary zinc sources and pregnancy in zinc utilization in adult women fed controlled diets. J Nutr 1983; 113: 2557–67
  • Tumlund J. R. Trace element utilization in humans studied with enriched stable isotopes and thermal ionization mass spectrometry. Stable isotopes in nutrition. American Chemical Society Symp. Ser. 258, J. R. Tumlund, P. E. Johnson. American Chemical Society, Washington, DC 1984; 41–53
  • Wada L., Tumlund J. R., King J. C. Zinc utilization in young men fed adequate and low zinc intakes. J Nutr 1985; 115: 1345–54
  • Tumlund J. R., Costa F., Durkin N., Margen S. Stable isotope studies of zinc absorption and retention in young and elderly men. J Nutr 1986; 116: 1239–47
  • Tumlund J. R. Thermal ionization mass spectral analysis for stable isotope studies on mineral metabolisms in humans. In: Proc. 34th ASMS Conf. Mass Spectrometry and Allied Topics. Pp. 260–61. Cincinnati, OH. June 8 to 13, 1986
  • Tumlund J. R., Reager R. D., Costa F. Iron and copper absorption in young and elderly men. Nun-Res 1988; 8: 333–43
  • Turnlund J. R., Wada L., King J. C., Keyes W. R., Acord L. L. Copper absorption in young men fed adequate and low zinc diets. Biol Trace Elem Res 1988; 17: 31–41
  • Turnlund J. R., Keyes W. R., Anderson H. L., Acord L. L. Copper absorption and retention in young men at three levels of dietary copper using the stable isotope 65Cu. Am J Clin Nutr 1989; 49: 870–78
  • Tumlund J. R., Smith R. G., Kretsch M. J., Keyes W. R., Shah A. G. Milk's effect on the bioavailability of iron from cereal-based diets in young women by the use of in vitro and in vivo methods. Am J Clin Nutr 1990; 52: 373–78
  • Turnlund J. R., Keyes W. R. Automated analysis of stable isotopes of zinc, copper, iron, calcium and magnesium by thermal ionization mass spectrometry using double isotope dilution for tracer studies in humans. J Micronutr Anal 1990; 7: 117–45
  • Turnlund J. R. Multi-isotope dilution techniques used with multiple-collector, thermal ionization mass spectrometry to investigate mineral metabolism in humans. Proc 39th ASMS Conf. Mass Spectrometry and Allied Topics. Pp. 563–64. Nashville, TN. May 19 to 24, 1991
  • Yergey A. L., Vieira N. E., Hansen J. W. Isotope ratio measurements of urinary calcium with a thermal ionization probe in a quadrupole mass spectrometer. Anal Chem 1980; 52: 1811–4
  • Yergey A. L., Covell D. G., Vieira N. E., Muenzer J. Studies of calcium metabolism using isotope dilution thermal ionization mass spectrometry. Proc 34th ASMS Conf. Mass Spectrometry and Allied Topics. Pp 262–63. Cincinnati, OH. June 8 to 13, 1986
  • Yergey A. L., Vieira N. E., Covell D. G. Direct measurement of dietary fractional absorption using calcium isotopic tracers. Biomed Environ Mass Spectrom 1987; 14: 603–07
  • Hillman L. S., Tack E., Covell D. G., Vieira N. E., Yergey A. L. Measurement of true calcium absorption in premature infants using intravenous 46Ca and oral Ca. Pediatr Res 1988; 23: 589–94
  • Vieira N. E., Yergey A. L. Equilibration of Ca isotopic tracer in infant formula. Proc. 36th ASMS Conf. Mass Spectrometry and Allied Topics. Pp. 508–09. San Francisco, CA. June 5 to 10, 1988
  • Eastell R., Vieira N. E., Yergey A. L., Riggs B. L. New one day test using stable isotopes to measure true fractional Ca absorption. J Bone Min Res 1989; 4: 463–68
  • Yergey A. L., Abrams S. A., Vieira N. E., Eastell R., Hillman L. S., Covell D. G. Recent studies of human calcium metabolism using stable isotopic tracers. Can J Physiol Pharmacol 1990; 68: 973–76
  • Abrams S. A., Vieira N. E., Yergey A. L. Unequal distribution of a stable isotopic calcium tracer between casein and whey fractions of infant formulas, human milk and cow's milk. J Nutr 1990; 120: 1672–76
  • Abrams S. A., Esteban N. V., Vieira N. E., Yergey A. L. Dual tracer stable isotopic assessment of calcium absorption and endogenous fecal excretion in low birth weight infants. Pediatr Res. 1991; 29: 615–18
  • Yergey A. L., Abrams S. A., Esteban N. V., Vieira N. E. Absorption of dietary calcium using dual stable isotopic tracers and thermal ionization mass spectrometry. Proc. 39th ASMS Conf. Mass Spectrometry and Allied Topics. Pp. 565–66. Nashville, TN. May 19 to 24, 1991
  • Vieira N. E., Hachey D. L., Yergey A. L. The use of TIMS/IDMS to characterize the extraction of Ca-enriched biological fluids using ion exchange membrane filter. Proc. 39th Conf. Mass Spectrometry and Allied Topics. Pp. 1071–72. Nashville, TN. May 19 to 24, 1991
  • Vieira N. E., Montes J. G., Sjodin R. A., Wu Y., Yergey A. L. Measurement of the potassium isotope ratio for the study of cellular fluxes. Proc. 38th ASMS Conf. Mass Spectrometry and Allied Topics. Pp. 1449–50. Tucson, AZ. June 3 to 8, 1991
  • Vieira N. E., Montes J. G., Sjodin R. A., Wu Y., Yergey A. L. Measurement of magnesium isotopic ratios in the study of bidirectional cellular magnesium fluxes. Proc. 37th ASMS Conf. Mass Spectrometry and Allied Topics. Pp. 592–93. Miami Beach, FL. May 21 to 26, 1989
  • Price R. I., Kent G. N., Rosman KJR, Gutteridge D. H., Reeve J., Allen J. P., Stuckey BGA, Smith M., Gulefi G., Hickling C. J., Blakeman S. L. Kinetics of intestinal calcium absorption in humans measured using stable isotopes and high precision thermal ionization mass spectrometry. Biomed Environ Mass Spectrom 1990; 19: 353–59
  • Fleishman D. G., Nikiforov V. A., Saulus A. A. Endogenous lithium determination in blood plasma and urine by isotope dilution mass spectrometry and preliminary isolation of lithium fraction using paper chromatography. Biol Mass Spectrom 1992; 21: 80–84
  • Lloyd J. R., Field F. H. Analysis of lithium using a commercial quadrupole mass spectrometer. Biol Mass Spectrom 1981; 8: 19–24
  • Frederickson C. J., Manton W. I., Frederickson M. H., Howell G. A., Mallory M. A. Stable isotope dilution measurement of zinc and lead in rat hippocampus and spinal cord. Brain Res 1982; 246: 338–41
  • Klitenick M. A., Frederickson C. J., Manton W. I. Acid-vapor decomposition for determination of zinc in brain tissue by isotope dilution mass spectrometry. Anal Chem. 1983; 55(6)921–23
  • Fassett J. D., Kingston H. M. Determination of nanogram quantities of vanadium in biological material by isotope dilution thermal ionization mass spectrometry with ion counting detection. Anal Chem 1985; 57: 2474–78
  • Gramlich J. W., Machlan L. A., Brletic K. A., Kelly W. R. Thermal ionization isotope dilution mass spectrometry as a definitive method for determination of potassium in serum. Clin Chem 1982; 28: 1309–13
  • Vanderpool R. A., Johnson P. E. Natural abundance and enriched boron isotope ratios in plant material. Proc. 38th ASMS Conf. Mass Spectrometry and Allied Topics. Pp. 79–80. Tucson, AZ. June 3 to 8, 1991
  • Lang S. J., Rosman KJR. Determination of lead in fresh and canned pineapple by isotope dilution mass spectrometry and isotope systematics. Anal Chim Acta 1990; 235: 367–73
  • Jackson M. J., Jones D. A., Edwards RHT, Swainbank I. G., Coleman M. L. Zinc homeostasis in man: studies using a new stable isotope dilution technique. BrJNutr 1984; 51: 199–208
  • Beattie J. H., Macdonald A., Harthill J. J., Bacon J. R. A technique to improve the determination of copper metabolism in small animals using stable isotopes. J Nutr Biochem 1991; 2: 512–20
  • Kelly W. R., Fassett J. D., Hotes S. A. Determining picogram quantities of uranium in human urine by thermal ionization mass spectrometry. Health Phys 1987; 52: 331–36
  • Kelly W. R., Fassett J. D., Hotes S A. Determination of picogram quantities of uranium in biological tissues by isotope dilution thermal ionization mass spectrometry with ion counting detection. Anal Chem 1983; 55: 1040–44
  • Heumann K. G., Koppe M., Wachsmann M. New developments in negative thermal ionization mass spectrometry and its applications. Proc. 37th ASMS Conf. Mass Spectrometry and Allied Topics. Pp. 414–16. Miami Beach, FL. May 21 to 26, 1989
  • Heumann K. G. Isotope dilution mass spectrometry. Inorganic mass spectrometry, F. Adams, R. Gijbels, R. VanGrieken. John Wiley & Sons, New York 1988; 301–76
  • Houk R. S., Fassel V. A., Flesch G. D., Svec H. J., Gray A. L., Taylor C. F. Inductively coupled argon plasma as an ion source for mass spectrometric determination of trace elements. Anal Chem 1980; 52: 2283–89
  • Houk R. S., Thompson J. J. Trace metal isotopic analysis of microlitre solution volumes by inductively coupled plasma mass spectrometry. Biomed Mass Spectrom 1983; 10: 107–12
  • Gray A. L. Progress in plasma source mass spectrometry. Spectrochim Acta. 1983; 38B: 29–37
  • Douglas D. J., Houk R. S. Inductively coupled plasma mass spectrometry. Prog Anal At Spectrosc 1985; 8: 1–18
  • Houk R. S. Mass spectrometry of inductively coupled plasma. Anal Chem 1986; 58(97)A1–5A
  • Russ GP, III, Bazan J. M. Isotope ratio measurements with an inductively coupled plasma source mass spectrometer. Spectrochim Acta. 1987; 42B: 49–62
  • Houk R. S., Thompson J. J. Inductively coupled plasma mass spectrometry. Mass Spectrom Rev. 1988; 7: 425–61
  • Gray A. L. Mass spectrometry with an inductively coupled plasma as an ion source: the influence on ultra trace analysis of background and matrix response. Spectrochim Acta. 1986; 41B: 151–67
  • Date A. R., Cheung Y. Y., Stuart M. E. The influence of polyatomic ion interferences in analysis by inductively coupled plasma mass spectrometry. Spectrochim Acta. 1987; 42B: 3–20
  • Vaughan M. A., Horlick G. Oxide, hydroxide and double charged analyte species in ICP/MS. Appl Spectrom 1986; 40: 434–45
  • Tan S. H., Horlick G. Background spectral features in ICP/MS. Appl. Spectrom 1986; 40: 445–60
  • Bradshaw N., Hall EFH, Sanderson N. E. Inductively coupled plasma as an ion source for high resolution mass spectrometry. J Anal At Spectrom 1989; 4: 801–03
  • Vanhoe H., Vandecasteele C., Versieck J., Dams R. Determination of iron, cobalt, copper, zinc, rubidium, molybdenum and cesium in human serum by inductively coupled plasma mass spectrometry. Anal Chem 1989; 61: 1851–57
  • Vanhoe H., Vandecasteele C., Versieck J., Dams R. Determination of trace elements in a human serum reference material by inductively coupled plasma mass spectrometry. Mikrochim Acta 1989; 3: 373–79
  • Vandecasteele C., Vanhoe H., Dams R., Vanballenberghe L., Wittoek A., Versieck J. Determination of strontium in human serum by inductively coupled plasma mass spectrometry and neutron activation analysis: a comparison. Talanta 1990; 37: 819–23
  • Vandecasteele C., Vanhoe H., Dams R., Versieck J. Determination of bromine in human serum by inductively coupled plasma mass spectrometry. Anal Lett 1990; 23: 1827–11
  • Vanhoe H., Vandecasteele C., Versieck J., Dams R. Determination of lithium in biological samples by inductively coupled plasma mass spectrometry. Anal Chim Acta 1991; 244: 259–67
  • Vanhaecke F., Vanhoe H., Dams R., Vandecasteele C. The use of internal standards in ICP-MS. Talanta 1992; 39: 737–42
  • Lyon TDB, Fell G. S., Hutton R. C., Eaton A. N. Evaluation of inductively coupled argon plasma mass spectrometry for simultaneous multi-element trace analysis in clinical chemistry. J Anal At Spectrom 1988; 3: 265–71
  • Lyon TDB, Fell G. S., Hutton R. C., Eaton A. N. Elimination of chloride interference on the determination of selenium in serum by inductively coupled plasma mass spectrometry. J Anal At Spectrom 1988; 3: 601–03
  • Lyon TDB, Fell G. S. Isotopic composition of copper in serum by inductively coupled plasma mass spectrometry. J Anal At Spectrom 1990; 5: 135–37
  • Lyon TDB, Fell G. S., McKay K., Scott R. D. Accuracy of multi-element analysis of human tissue obtained at autopsy using inductively coupled plasma mass spectrometry. J Anal At Spectrom 1991; 6: 559–64
  • Abou-Shakra FR, Havercroft J. M., Ward N. I. Lithium and boron in biological tissues and fluids. Trace Elem Med 1989; 6: 142–46
  • Ward N. I., Abou-Shakra FR, Durrant S. F. Trace element content of biologic materials: a comparison of neutron activation analysis and inductively coupled plasma-mass spectrometry analysis. Biol Trace Elem Res 1990; 177–87
  • Schmit J. P., Youla M., Gelinas Y. Multielement analysis of biological tissues by inductively coupled plasma mass spectrometry. Anal Chim Acta 1991; 249: 495–501
  • Hinners T. A., Heithmar E. M., Spittler T. M., Henshaw J. M. Inductively coupled plasma mass spectrometric determination of lead isotopes. Anal Chem 1987; 59: 2658–02
  • Lasztity A., Viczian M., Wang X., Barnes R. M. Sample analysis by on-line isotope dilution inductively coupled plasma mass spectrometry. J Anal At Spectrom 1989; 4: 761–66
  • Viczian M., Lasztity A., Barnes R. M. Identification of potential environmental sources of childhood lead poisoning by inductively coupled plasma mass spectrometry: verification and case studies. J Anal At Spectrom 1990; 5: 293–300
  • Campbell M. J., Delves H. T. Accurate and precise determination of lead isotope ratios in clinical and environmental samples using inductively coupled plasma source mass spectrometry. J Anal At Spectrom 1989; 4: 235–36
  • Buckley W. T., Budac J. J., Godfrey D. V., Koenig K. M. Determination of selenium by inductively coupled plasma mass spectrometry utilizing a new hydride generation sample introduction system. Anal Chem 1992; 64: 724–29
  • Newman R. A., Osbom S., Siddik Z. H. Determination of tellurium in biological fluids by means of electrothermal vaporization inductively coupled plasma-mass spectrometry (ETV-ICP-MS). Clin ChimActa 1989; 179: 191–96
  • Tothill P., Matheson L. M., Smyth J. F., McKay K. Inductively coupled plasma mass spectrometry for the determination of platinum in animal tissues and a comparison with atomic absorption spectroscopy. J Anal At Spectrom 1990; 5: 619–22
  • Allain P., Berre S., Mauras Y., LeBouil A. Evaluation of inductively coupled plasma mass spectrometry for the determination of platinum in plasma. Biol Mass Spectrom 1992; 21: 141–43
  • Templeton D. M., Vaughan M. A. Principal components analysis for the determination of nickel in urine by ICP-MS. Trace elements in health disease, A. Aitio, A. Aro, J. Jarvislo, H. Vainio. Royal Society of Chemistry, Cambridge 1991; 19–28
  • Dalgarno B. G., Brown R. M., Pickford C. J. Potential of inductively coupled plasma mass spectrometry for trace element metabolism studies in man. Biomed Environ Mass Spectrom 1988; 16: 377–80
  • Allain P., Berre S., Premel-Cabic A., Mauras Y., Delaporte T., Coumot A. Investigation of the direct determination of uranium in plasma and urine by inductively coupled plasma mass spectrometry. Anal Chim Acta 1991; 251: 183–85
  • Igarashi Y., Kawamura H., Shiraishi K., Takaku Y. Determination of thorium and uranium in biological samples by inductively coupled plasma mass spectrometry using internal standardization. J Anal At Spectrom 1989; 4: 571–76
  • Kim C. K., Seki R., Morita S., Yamasaki S., Tsumura A., Takaku Y., Igarashi Y., Yamamoto M. Application of a high resolution inductively coupled plasma mass spectrometer to the measurement of long-lived radionuclides. J Anal At Spectrom 1991; 6: 205–09
  • Janghorbani M., Ting BTG., Young V. R. Absorption of iron in young men studied by monitoring excretion of a stable iron isotope (58Fe) in feces. J Nutr 1980; 110: 2190–97
  • Janghorbani M., Istfan N. W., Young V. R. Stable isotope approaches for measurement of dietary zinc availability in humans. Nutritional bioavailability of zinc. Symp. Ser. 210, G. E. Inglet. American Chemical Society, Washington, DC 1983; 41–59
  • Janghorbani M. Stable isotopes in nutrition and food science. Prog Food Nutr Sci 1984; 8: 303–32
  • Ehrenkranz R. A., Ackerman B. A., Nelli C. M., Janghorbani M. Absorption of calcium in premature infants as measured with a stable isotope 46Ca extrinsic tag. Pediatr Res 1985; 19: 178–84
  • Janghorbani M., Young V. R., Ehrenkranz R. A. Isotopic methods in the study of mineral metabolism in infants with special reference to stable isotopes. Trace elements in nutrition of children. Nestle's Nutrition Workshop Series, R. K. Chandra. Raven Press, New York 1985; Vol 8: 63–86
  • Janghorbani M., Ting BTG, Fomon S. J. Erythrocyte incorporation of ingested stable isotope analysis of iron (58Fe). Am J Hematol 1986; 21: 277–88
  • Ting BTG, Janghorbani M. Inductively coupled plasma mass spectrometry applied to isotopic analysis of iron in human fecal material. Anal Chem 1986; 58: 1334–40
  • Sun X. F., Ting BTG, Zeisel S. H., Janghorbani M. Accurate measurement of the stable isotopes of lithium by inductively coupled plasma mass spectrometry. Analyst 1987; 112: 1223–28
  • Ting BTG, Janghorbani M. Application of ICP-MS to accurate isotopic analysis for human metabolic studies. Spectrochim Acta. 1987; 42B: 21–7
  • Janghorbani M., Davis T. A., Ting BTG. Measurement of stable isotopes of bromine in biological fluids with inductively coupled plasma mass spectrometry. Analyst 1988; 113: 405–11
  • Schuette S., Vereault D., Ting BTG, Janghorbani M. Accurate measurements of stable isotopes of magnesium in biological materials with ICPMS. Analyst 1988; 113: 1837–42
  • Woodhead J. C., Drulis J. M., Rogers R. R., Zeigler E. E., Stumbo P. J., Janghorbani M., Ting BTG, Fomon S. J. Use of stable isotope 5*Fe for determining availability of non-heme iron in meals. PediatrRes 1988; 23: 495–99
  • Fomon S. J., Janghorbani M., Ting BTG, Zeigler E. E., Rogers R. R., Nelson S. E., Ostedgaard L. S., Edwards B. B. Erythrocyte incorporation of ingested 58Fe by infants. Pediatr Res 1988; 24: 20–4
  • Janghorbani M., Ting BTG. Comparison of pneumatic nebulization and hydride generation of ICP-MS for isotope analysis of selenium. Anal Chem 1989; 61: 701–8
  • Ting BTG, Mooers C. S., Janghorbani M. Quantitative isotopic analysis for selenium in biological materials with inductively coupled plasma mass spectrometry. Analyst 1989; 114: 667–74
  • Schuette S., Vereault D., Ting B., Janghorbani M. In vivo studies of magnesium exchange utilizing the stable isotope :5Mg in the rat. Mag Res 1989; 2: 51–2
  • Ehrenkranz R. A., Gettner P. A., Nelli C. M., Sherwonit E. A., Williams J. E., Ting BTG, Janghorbani M. Zinc and copper nutritional studies in very low birth weight infants: comparison of stable isotope extrinsic tag and chemical balance methods. Pediatr Res 1989; 26: 298–307
  • Schuette S., Hong J., Vereault D., Ting B., Janghorbani M. Effect of magnesium nutriture on the dynamics of administered 25Mg exchange in vivo on rat. J Nutr Biochem 1990; 1: 355–61
  • Schuette S., Zeigler E. E., Nelson S. E., Janghorbani M. Feasibility of using stable isotope 25Mg to study Mg metabolism in infants. Pediatr Res 1990; 27: 36–40
  • Janghorbani M. Inductively coupled plasma mass spectrometry as a tool in investigations of trace element metabolism. Proc. 39th ASMS Conf. Mass Spectrometry and Allied Topics. Pp. 560–61. Nashville, TN. May 19 to 24, 1991
  • Woodhead J. C., Drulis J. M., Nelson S. E., Janghorbani M., Fomon S. J. Gender-related differences in iron absorption by preadolescent children. Pediatr Res 1991; 29: 435–9
  • Schuette S. A., Hartmann S. C., Ting BTG, Janghorbani M. Feasibility of measuring organ magnesium turnover in vivo by continuous feeding of a stable isotope. J Nutr Biochem 1992; 3: 38–44
  • Serfass R. E., Thompson J. J., Houk R. S. Isotope ratio determinations by ICP/MS for zinc bioavailability studies. Anal Chim Acta 1986; 188: 73–84
  • Serfass R. E., Lindberg G. L., Olivares J. A. Intrinsic labeling of bovine milk with zinc stable isotope analysis by ICPMS. Fed Proc 1985; 44: 933
  • Serfass R. E., Thompson J. J., Zeigler E. E. Intrinsic and extrinsic zinc absorption by infants from cow milk formula. Fed Proc 1986; 45: 588
  • Serfass R. E., Thompson J. J., Houk R. S. Isotope ratios by ICPMS for mineral bioavailability studies. Proc. 34th ASMS Conf. Mass Spectrometry and Allied Topics. Pp. 264–65. Cincinnati, OH. June 8 to 13, 1986
  • Zeigler E. E., Serfass R. E., Nelson S. E., Figueroa-Colon R., Edwards B. B., Houk R. S., Thompson J. J. Effect of low zinc intake on absorption and excretion of zinc by infants studied with 70Zn as extrinsic tag. J Nutr 1989; 119: 1647–53
  • Serfass R. E., Zeigler E. E., Edwards B. B., Houk R. S. Intrinsic and extrinsic stable isotopic zinc absorption in infants from formulas. J Nutr 1989; 119: 1661–9
  • Smith F. G., Serfass F. E., Houk R. S. Improvements in sensitivity and precision of isotope ratio measurements by ICPMS. Proc. 38th ASMS Conf. Mass Spectrometry and Allied Topics. Pp. 83–84. Tucson, AZ. June 3 to 8, 1990
  • Serfass R. E., Smith F. G., Houk R. S. Boron concentrations and isotope ratios in human blood plasma and biological reference materials by ICPMS with direct injection nebulization. Proc. 39th ASMS Conf. Mass Spectrometry and Allied Topics. Pp. 562. Nashville, TN. May 19 to 24, 1991
  • Smith F. G., Wiederin D. R., Houk R. S., Egan C. B., Serfass R. E. Measurement of boron concentration and isotope ratios in biological samples by inductively coupled plasma mass spectrometry with direct injection nebulization. Anal Chim 1991; 248: 229–34
  • Whittaker P. G., Lind T., Williams J. G., Gray A. L. Inductively coupled plasma mass spectrometric determination of the absorption of iron in normal women. Analyst 1989; 114: 675–8
  • Whittaker P. G., Barrett JFR, Williams J. G. Precise determination of iron isotope ratios in whole blood using inductively coupled plasma mass spectrometry. J Anal At Spectrom 1992; 7: 109–13
  • Schwartz R. Stable magnesium isotopes as tracers using inductively coupled plasma mass spectrometry. J Micronutr Anal 1990; 8: 13–22
  • Dever M., Hausler D. W., Smith J. E. Comparison between radioactive isotope 5lCr and stable isotope 50Cr labels for the determination of red blood cell survival. J Anal At Spectrom 1989; 4: 361–3
  • Hu K., Clemons P. S., Houk R. S. Inductively coupled plasma mass spectrometry with an enlarged sampling orifice and offset ion lens. J Am Soc Mass Spectrom 1993; 4: 16–27
  • Smith D. L. Determination of stable isotopes of calcium in biological fluids by fast atom bombardment mass spectrometry. Anal Chem 1983; 55: 2391–3
  • Smith D. L., Atkin C., Westenfelder C. Stable isotopes of calcium as tracers: methodology. Clin Chim Acta 1985; 146: 97–101
  • Jiang X., Liu Y., Smith D. L., Shu I., Weaver C. Quantitation and use of stable isotopes of calcium in calcium nutrition studies. Proc. 34th ASMS Conf. Mass Spectrometry and Allied Topics. Pp. 266–67. Cincinnati, OH. June 8 to 13, 1986
  • Liu Y-M, Jiang X., Martin B, Weaver C., Smith D. L. Determination of isotopic abundances of calcium and magnesium by FABMS. Proc. 35th ASMS Conf. Mass Spectrometry and Allied Topics. Pp. 688–9. Denver, CO. May 24 to 29, 1987
  • Jiang X., Smith D. L. Quantitation of stable isotopic tracers of calcium by fast atom bombardment mass spectrometry. Anal Chem 1987; 59: 2570–4
  • Liu Y-M, Smith D. L., Neal P., Lemons J. Magnesium metabolism in humans: quantitation of stable isotopes by FABMS. Proc. 36th ASMS Conf. Mass Spectrometry and Allied Topics. Pp. 506–7. San Francisco, CA. June 5 to 10, 1988
  • Liu Y-M, Neal P., Ernst J., Weaver C., Rickard K., Smith D. L., Lemons J. Absorption of calcium and magnesium from fortified human milk by very low birth weight infants. PediatrRes 1989; 25: 496–502
  • Eagles J., Fairweather-Tait S. J., Self R. Stable isotope ratio mass spectrometry for iron bioavailability studies. Anal Chem 1985; 57: 469–71
  • Self R., Fairweather-Tait S. J., Eagles J. A double stable isotope labeling method for iron bioavailability studies using fast atom bombardment mass spectrometry. Anal Proc 1985; 22: 194–5
  • Gharaibeh AAR, Eagles J., Self R. Determination of total iron in food by isotope dilution fast atom bombardment mass spectrometry. Biomed Mass Spectrom 1985; 12: 344–7
  • Pratt D. E., Eagles J., Fairweather-Tait S. J. Fast atom bombardment mass spectrometry method for monitoring zinc and calcium stable isotopes in bioavailability studies. J Micronutr Anal 1987; 3: 107–17
  • Self R., Eagles J., Fairweather-Tait S. J., Portwood D. E. Fast atom bombardment mass spectrometry of mineral nutrients in human nutrition studies. Anal Proc 1987; 24: 366–7
  • Pratt D. E., Eagles J., Self R. The current state of quantitative metal analysis by mass spectrometry. Mass spectrometry, M. E. Rose. Royal Chemical Society, London 1987; Vol. 9: 47–30
  • Miller L. V., Goss C., Hambidge K. M., Fennessey P. V. Mass discrimination phenomena in fast atom bombardment of metal stable isotopes. Proc. 34th ASMS Conf. Mass Spectrometry and Allied Topics. Pp. 268–9. Cincinnati, OH. June 8 to 13, 1986
  • Fennessey P. V., Miller L. V. Dry FAB mass spectrometric techniques increase practicality of and access to trace metal analysis in man. Proc. 37th ASMS Conf. Mass Spectrometry and Allied Topics. Pp. 411–3. Miami Beach, FL. May 21 to 26, 1989
  • Pierce P. L., Hambidge K. M., Goss C. H., Miller L. V., Fennessey P. V. Fast atom bombardment mass spectrometry for the determination of zinc stable isotopes in biological samples. Anal Chem 1987; 59: 2034–7
  • Miller L. V., Fennessey P. V. The use of secondary ion energy selection to suppress polyatomic, isobaric interferences in isotope analysis by FAB-MS. Proc. 38th ASMS Conf. Mass Spectrometry and Allied Topics. Pp. 77–8. Tucson, AZ. June 3 to 8, 1990
  • Miller L. V., Hambidge K. M., Fennessey P. V. Analytical considerations in trace metal isotope analysis using fast atom bombardment-induced ionization. Anal Chim Acta 1990; 241: 249–54
  • Miller L. V., Hambidge K. M., Fennessey P. V. Isotope fractionation and hydride interference in metal isotope analysis by fast atom bombardment-induced secondary ion mass spectrometry. J Micronutr Anal 1990; 8: 179–197
  • Fennessey P. V., Lloyd-Kindstrand L., Hambidge K. M. The study of trace metal absorption using stable isotopes and mass spectrometry. Int J Mass Spectrom Ion Proc 1991; 111: 355–64
  • Eagles J., Fairweather-Tait S. J., Portwood D. E., Self R., Gotz A., Heumann KG. Comparison of fast atom bombardment mass spectrometry and thermal ionization quadrupole mass spectrometry for the measurement of zinc absorption in human nutrition studies. Anal Chem 1989; 61: 1023–5
  • Eagles J., Fairweather-Tait S. J., Mellon F. A., Portwood D. E., Self R., Gotz A., Heumann K. G., Crews H. M. Comparison of fast atom bombardment, thermal ionization and inductively coupled plasma mass spectrometry for the measurement of Znn stable isotopes in human nutrition studies. Rapid Comm Mass Spearom 1989; 3: 203–5
  • Fox T. E., Fairweather-Tait S. J., Eagles J., Wharf S. G. Intrinsic labeling of different foods with stable isotope of zinc (67Zn) for use in bioavailability studies. Br J Nutr 1991; 66: 57–63
  • Fairweather-Tait S. J., Fox T. E., Wharf S. G., Eagles J., Crews H. M., Massey R. Apparent zinc absorption by rats from foods labelled intrinsically and extrinsically with 67Zn. Br J Nutr 1991; 66: 65–71
  • Lehmann W. D., Fischer R., Heinrich H. C. Iron absorption in man calculated from erythrocyte incorporation of the stable isotope MFe determined by fast atom bombardment mass spectrometry. Anal Biochem 1988; 172: 151–9
  • Lehmann W. D., Schulten H. R. Determination of alkali elements by field desorption mass spectrometry. Anal Chem 1977; 49: 1744–6
  • Lehmann W. D., Bahr U., Schulten H. R. Determination of lithium in microlitre amounts of human body fluids at therapeutic and normal levels by stable isotope dilution and field desorption mass spectrometry. Biomed Mass Spectrom 1978; 5: 536–9
  • Achenbach C., Ziskoven R., Koehler F., Bahr U., Schulten H. R. Quantitative trace analysis of thallium in biological material. Angew Chem Int Ed Engl 1979; 18: 882–3
  • Achenbach C., Hauswirth O., Heindrichs C., Ziskoven R., Koehler F., Bahr U., Heindrichs A., Schulten H. R. Quantitative measurement of time-dependent thallium distribution in organs of mice by field desorption mass spectrometry. J Toxicol Environ Health 1980; 6: 519–28
  • Schulten H. R., Bohl B., Bahr U., Mueller K., Palavinskas R. Qualitative and quantitative trace metal analysis in physiological fluids of multiple sclerosis patients by field desorption mass spectrometry. Int J Mass Spectrom Ion Phys 1981; 38: 281–95
  • Bahr U., Schulten H. R., Achenbach C., Ziskoven R. Interlaboratory determinations of isotopically enriched metals by field desorption mass spectrometry. Z. Anal Chem 1982; 312: 307–10
  • Lehmann W. D., Schuken H. R. Stable isotopes, H. L. Schmidt, H. Forstel, K. Heinzinger. Elsevier, Amsterdam 1982; 635–7
  • Lehmann W. D., Kessler M. Calcium absorption studies in man by stable isotope dilution and field desorption mass spectrometry. Stable isotopes, H. L. Schmidt, H. Forstel, K. Heinzinger. Elsevier, Amsterdam 1982; 649–54
  • Schulten H. R., Monkhouse P. B. Fast quantitative trace analyses of metals in inorganic and biological materials. Am Lab March, 1983; 44–54
  • Schulten H. R., Palavinskas R., Kriesten K. Quantification of alkaline-earth metals in rabbit fetuses during the last two weeks of gestation by field desorption mass spectrometry. Z. Anal Chem 1983; 315: 459–63
  • Ramseyer GO, Morrison G. H. Relative sensitivity factors of elements in quantitative secondary ion mass spectrometric analysis of biological reference materials. Anal Chem 1983; 55: 1963–70
  • Burns-Bell-Horn MS, File D. M. Secondary ion mass spectrometry of standards for analysis of soft biological tissues. Anal Biochem 1979; 92: 213–21
  • Bums M. S. Selection of calcium isotopes for secondary ion mass spectrometric analysis of biological material. J Microsc 1984; 135: 209–12
  • Ramseyer G. O., Brenna J. T., Morrison G. H., Schwartz R. Elemental isotopic abundance determinations of magnesium in biological materials by secondary ion mass spectrometry. Anal Chem 1984; 56: 407–11
  • Kron T., Wittmaack K., Hansen C., Wemer E. Stable isotopes for determining biokinetic parameters of tellurium in rabbits. Anal Chem 1991; 63: 2603–7
  • Heurteaux C., Ripoll C., Ouznadji S., Ouznadji H., Wissocq J-C, Thellier M. Lithium transport in the mouse brain. Brain Res 1991; 547: 122–8
  • Smith D. H., Young J. P., Shaw R. W. Elemental resonance ionization mass spectrometry: a review. Mass Spectrom Rev 1989; 8: 345–78
  • Fassett J. D., Travis J. C. Analytical applications of resonance ionization mass spectrometry. Spectrochim Acta. 1988; 43B: 1408–22
  • Fassett J. D., Walker R. J., Travis J. C., Ruegg F. C. Measurement of low abundance isotopes by laser resonance ionization mass spectrometry. Anal Instr 1988; 17: 69–86
  • Fassett J. D., Powell L. J., Moore L. J. Determination of iron in serum and water by resonance ionization isotope dilution mass spectrometry. Anal Chem 1984; 56: 2228–33
  • Moore L. J., Parks J. E., Taylor E. H., Beekman D. W., Spaar M. T. Medical and biological applications of resonance ionization spectroscopy (RIS). Resonance ionization spectroscopy, G. S. Hurst, M. G. Payne. Institute of Physics, Bristol 1987; 239
  • Nogar N. S., Estler R. C. Chromium detection by laser desorption and resonance ionization mass spectrometry. Anal Chem 1992; 64: 465–8
  • Estler R. C., Conia J., Nogar N. S. RIMS in biochemical systems. 6th Int. Symp. Resonance Ionization Spectroscopy and its Applications. Santa Fe, NM. May 24 to 29, 1992
  • Litherland A. E. Ultrasensitive mass spectrometry with accelerators. Annu Rev Nucl Sci 1980; 30: 437–73
  • Kutschera W. Accelerator mass spectrometry: a versatile tool for research. Nucl Instr Methods PhysRes. 1990; B50: 252–61
  • Vogel J. S., Turteltaub K. W., Felton J. S., Gledhili B. L., Nelson D. E., Southon J. R., Proctor I. D., Davis J. C. Applications of AMS to the biomedical sciences. Nucl Instr Methods Phys Res. 1990; B52: 524–30
  • Elmore D. Ultrasensitive radioisotope, stable isotope and trace-element analysis in the biological sciences using tandem accelerator mass spectrometry. Biol Trace Elem Res 1987; 12: 231–45
  • Middleton R., Klein J. 26A1: measurement and applications. Philos Trans R Soc London Ser A 1987; 323: 121–43
  • Meirav O., Sutton RAL, Fink D., Middleton R., Klein J., Walker V. R., Halabe A., Vetterli D., Johnson R. R. Accelerator mass spectrometry: application to study of aluminum kinetics in the rat. Am J Physiol 1991; 260: F466–9
  • Barker J., Day J. P., Priest N. D., Newton D., Drumm P. V., Lilley J. S., Newton GWA. Development of 26A1 accelerator mass spectrometry for aluminum absorption experiments in humans. Nucl lnstr Methods Phys Res. 1992; B68: 319–22
  • Elmore D., Bhattacharyya M. H., Sacco-Gibson N., Peterson D. D. 41Ca as a long term biological tracer for bone resorption. Nucl lnstr Methods Phys Res. 1990; B52: 531–5
  • King F. L., Harrison Glow W. W. discharge mass spectrometry: an introduction to the technique and its utility. Mass Spectrom Rev 1988; 9: 285–318
  • Stuewer D. Glow discharge mass spectrometry – a versatile tool for chemical analysis. 7. Anal Chem 1990; 337: 737–42
  • Evetts I., Milton D., Mason R. Trace element analysis in body fluids by glow discharge mass spectrometry: a study of lead mobilization by the drug cis-platin. Biol Mass Spectrom 1991; 153–9
  • Verbueken A., Michiels E., VanGrieken R. Total analysis of plant material and biological tissue by spark source mass spectrometry. Z. Anal Chem 1981; 309: 300–4
  • Vos L., VanGrieken R. Spark source mass spectrometry for trace analysis of diverse biological matrices. Int J Mass Spectrom Ion Phys 1983; 47: 303–6
  • Bacon J. R., Ure A. M. Matrix effects and interferences in the spark source mass spectrometry on non-conducting powders of agricultural interest. Adv Mass Spectrom. 1980; 8A: 362–73
  • Poon G. K., Mistry P., Lewis S. Electrospray ionization mass spectrometry of platinum anticancer agents. Biol Mass Spectrom 1991; 20: 687–92
  • Belcher R., Martin R. J., Stephen W. I., Henderson D. E., Kamalizad A., Uden P. C. Gas chromatography of divalent transition metal chelates. Anal Chem 1973; 45: 1197–1203
  • Sucre L., Jennings W. Detection of metal ions by glass capillary gas-chromatographic separation of their volatile chelates. J High Resolut Chromatogr Chromatogr Commun 1980; 3: 452–60
  • Schwedt G., Russel H. A. Gas chromatography of Tl, Se, Te, Hg, As, Sb, Bi, Sn as phenyl compounds. Z. Anal Chem 1973; 264: 301–3
  • Rodriguez-Vazquez J. A. Quantitative inorganic analysis by gas chromatography: a review. Anal Chim Acta 1974; 73: 1–32
  • Uden P. C., Henderson D. E. Determination of metals by gas chromatography of metal complexes: a review. Analyst. 1977; 102(1221)889–916
  • Sokolov D. N. Gas-chromatographic analysis of metals as volatile complexes. Russ Chem Rev 1977; 46: 388–93
  • Sievers R. E., Sadlowski J. E. Volatile metal complexes. Science 1978; 201(4352)217–23
  • Schwedt G. Chromatography in inorganic trace analysis. Topics Curr Chem 1979; 85: 159–212
  • Neeb R. Metal-chelate gas-chromatography for trace element analysis. Pure Appl Chem 1982; 54: 847–52
  • Riekkola M-L. Gas chromatographic behavior of some metal di(trifluoroethyl)- and di-isobutyldithiocarbamate chelates on short capillary columns. Mikrochim Acta 1983; 2: 381–9
  • Riekkola M-L. Mass spectrometric study on several metal dialkyldithiocarbamate chelates. Acta Chem Scand. 1983; A37: 691–6
  • Uden P. C. Inorganic gas chromatography. J Chromatogr 1984; 313: 3–31
  • Nickless G. Trace metal determination by chromatography. J Chromatogr 1985; 313: 129–59
  • Johnson P. E. A mass spectrometric method for use of stable isotopes as tracers in studies of iron, zinc and copper absorption in human subjects. J Nutr 1982; 112: 1414–24
  • Johnson P. E. Stable isotopes of iron, zinc and copper used to study mineral absorption in humans. Stable isotopes in nutrition. ACS Symp. Ser. 258, J. R. Tumlund, P. E. Johnson. American Chemical Society, Washington, DC 1984; 139–55
  • Johnson P. E., Lykken G. I. 65Cu absorption by men fed intrinsically and extrinsically labeled whole wheat bread. J Agric Food Chem 1988; 36: 537–40
  • Johnson P. E., Stuart M. A., Hunt J. R., Mullen L., Starks T. L. Cu absorption by women fed intrinsically and extrinsically labeled goose meat, goose iiver, peanut butter and sunflower butter. JNutr 1988; 118: 1522–8
  • Davis B. A., Hui K. S., Durden D. A., Boulton A. A. Qualitative and quantitative mass spectrometry of some biologically important trace metals as their tetraphenyl porphyrin chelates. Biomed Mass Spectrom 1976; 3: 71–6
  • Hui K. S., Davis B. A., Boulton A. A. Analysis of copper in brain by the mass spectrometric integrated-ion-current procedure. Neurochem Res 1977; 2: 495–506
  • Buckley W. T., Hucken S. N., Budac J. J., Elgendorf G. K. Mass spectrometric determination of a stable isotope tracer for copper in biological materials. Anal Chem 1982; 54: 504–10
  • Hachey D. L., Blais J., Klein P. D. High precision isotope ratio analysis of volatile metal chelates. Anal Chem 1980; 52: 1131–5
  • Schwartz R., Giesecke C. C. Mass spectrometry of a volatile magnesium chelate in the measurement of stable 26Mg when used as a tracer. Clin Chim Acta 1979; 97: 1–8
  • Schwartz R., Grunes D. L., Wentworth R. A., Wien E. M. Magnesium absorption from leafy vegetables intrinsically labelled with stable isotope 26Mg. J Nutr 1980; 110: 1365–71
  • Schwartz R. 26Mg as a probe in research on the role of magnesium in nutrition and metabolism. FedProc. 1982; 41: 2709–13
  • Schwartz R. Stable :6Mg for dietary magnesium availability measurements. Stable isotopes in nutrition. ACS Symp. Ser. 258, J. R. Tumlund, P. E. Johnson. American Chemical Society, Washington, DC 1984; 77–89
  • Kowantzki R., Peters F., Reil G. H., Maa B. G. Volatile complexes for the determination of calcium in blood plasma by isotope dilution mass spectrometry. Biomed Mass Spectrom 1980; 7: 540–43
  • Kowantzki R., Peters F., Reil G. H. Determination of calcium isotopes in blood plasma by mass spectrometry. Z. Anal Chem 1980; 301: 179–80
  • Miller D. D., VanCampen D. A method for the detection and assay of iron stable isotope tracers in blood serum. Am J Clin Nutr 1979; 32: 2354–61
  • Veillon C., Wolf W. R., Guthrie B. E. Determination of chromium in biological materials by stable isotope dilution. Anal Chem 1979; 51: 1022–24
  • Reamer D. C., Veillon C. Determination of selenium in biological materials by stable isotope dilution gas chromatography-mass spectrometry. Anal Chem 1981; 53: 2166–69
  • Reamer D. C., Veillon C. A double isotope dilution method for using stable selenium isotopes in metabolic tracer studies: analysis by gas chromatography/mass spectrometry. J Nutr 1983; 113: 786–92
  • Swanson C. A., Reamer D. C., Veillon C., King J. C., Levander O. A. Quantitative and qualitative aspects of selenium utilization in pregnant and nonpregnant women: an application of stable isotope methodology. Am J Clin Nutr 1983; 38: 169–80
  • Wolf W. R., LaCroix D. E., Kochansky J. Evaluation of 4-trifluoromethyl-o-phenylenediamine for determination of selenium in biological materials by gas chromatography-atomic absorption spectrometry and stable isotope dilution mass spectrometry. J Micronutr Anal 1988; 4: 145–54
  • Moser-Veillon P. B., Mangels A. R., Patterson K. Y., Veillon C. Utilization of two different chemical forms of selenium during lactation using stable isotope tracers: an example of speciation in nutrition. Analyst 1992; 117: 559–62
  • Soltani-Neshan A., Domer K., Schaub J. Application of gas chromatography/mass spectrometry to the investigation of metabolic pathways of trace elements using stable isotopes as tracers. Z. Anal Chem 1988; 331: 202–4
  • Christie D. B., Hall M., Moynihan C. M., Hambidge K. M., Fennessey P. V. Bioactive trace metals and trace metal stable isotopes: quantitative analysis using mass spectrometric techniques. Stable isotopes in nutrition. ACS Symp. Sen 258, J. R. Turnlund, P. E. Johnson. American Chemical Society, Washington, DC 1984; 127–38
  • Brunmark P, Skarping G., Schutz A. Determination of methylmercury in human blood using capillary gas chromatography and selected ion monitoring. J Chromatogr 1992; 573: 35–41
  • Aggarwal S. K., Kinter M., Wills M. R., Savory J., Herold D. A. Determination of isotope ratios of chromium, nickel, zinc and copper by gas chromatography-mass spectrometry by using volatile metal chelates. Anal Chim Acta 1989; 224: 83–95
  • Aggarwal S. K., Kinter M., Wills M. R., Savory J., Herold D. A. Isotope dilution gas chromatogra-phy/mass spectrometry for the determination of nickel in biological materials. Anal Chem 1989; 61: 1099–1103
  • Aggarwal S. K., Kinter M., Wills M. R., Savory J., Herold D. A. Determination of chromium in urine by stable isotope dilution gas chromatography/mass spectrometry using lithium bis(trifluoroethyl)dithiocarbamate as a chelating agent. Anal Chem 1990; 62: 111–5
  • Aggarwal S. K., Kinter M., Herold D. A. Isotope dilution gas chromatography/mass spectrometry for platinum determination in urine. J Am Soc Mass Spectrom 1991; 2: 85–90
  • Aggarwal S. K., Kinter M., Herold D. A. Determination of copper in urine and serum by gas chromatography-mass spectrometry. Anal Biochem 1991; 194: 140–5
  • Aggarwal S. K., Kinter M., Herold D. A. Determination of selenium in urine by isotope dilution gas chromatography-mass spectrometry using 4-nitro-o-phenylenediamine, 3,5-dibromo-o-phenylenediamine and 4-trifluoromethyl-ophenylenediamine as derivatizing reagents. Anal Biochem 1992; 202: 367–74
  • Aggarwal S. K., Kinter M., Herold D. A. Determination of cobalt in urine by gas chromatography-mass spectrometry employing nickel as an internal standard. Chromatogr BiomedAppl 1992; 576: 297–304
  • Aggarwal S. K., Orth R. G., Wendling J., Kinter M., Herold D. A. Isotope dilution gas chromatography-mass spectrometry for cadmium determination in urine. J Anal Toxicol 1993; 17: 5–10
  • Herold D. A., Aggarwal S. K., Kinter M. Mercury determination by GC-MS using Li bis(trifluoroethyl)dithiocarbamate as the chelating agent. Clin Chem 1992; 38: 997
  • Herold D. A., Aggarwal S. K., Kinter M. Tellurium determination by GC-MS in biological samples. Clin Chem 1993; 39: 1237
  • Herold D. A., Aggarwal S. K., Kinter M. An improved GC-MS method for analysis of lead. Clin Chem 1993; 39: 1239
  • Aggarwal S. K., Gemma N., Kinter M., Nicholson J., Shipe JR, Jr, Herold D. A. Determination of platinum in urine, ultrafiltrate and whole plasma by isotope dilution gas chromatography-mass spectrometry and electrothermal atomic absorption spectrometry. Anal Biochem 1993; 210: 113–8
  • Herold D. A., Aggarwal S. K., Kinter M. Trace metal analysis by gas chromatography/mass spectrometry: a less-invasive analytical technique. Clin Chem 1992; 38: 1647–9

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.