11,498
Views
77
CrossRef citations to date
0
Altmetric
Review Article

Legionella detection by culture and qPCR: Comparing apples and oranges

&
Pages 65-74 | Received 02 Oct 2013, Accepted 17 Jan 2014, Published online: 03 Mar 2014

References

  • Al-Bana BH, Haddad MT, Garduno RA. (2013). Stationary phase and mature infectious forms of Legionella pneumophila produce distinct viable but non-culturable cells. Environ Microbiol 16:382–95
  • Al-Matawah QA, Al-Zenki SF, Qasem JA, et al. (2012). Detection and quantification of Legionella pneumophila from water systems in Kuwait residential facilities. J Pathogens 2012. Article ID: 138389
  • Alary M, Joly JR. (1992). Comparison of culture methods and an immunofluorescence assay for the detection of Legionella pneumophila in domestic hot water devices. Curr Microbiol 25:19–23
  • Alleron L, Merlet N, Lacombe C, Frère J. (2008). Long-term survival of Legionella pneumophila in the viable but nonculturable state after monochloramine treatment. Curr Microbiol 57:497–502
  • Asadi E, Costa JJ, Gameiro da Silva M. (2011). Indoor air quality audit implementation in a hotel building in Portugal. Building Environ 46:1617–23
  • Aurell H, Catala P, Farge P, et al. (2004). Rapid detection and enumeration of Legionella pneumophila in hot water systems by solid-phase cytometry. Appl Environ Microbiol 70:1651–7
  • Ballard AL, Fry NK, Chan L, et al. (2000). Detection of Legionella pneumophila using a real-time PCR hybridization assay. J Clin Microbiol 38:4215–18
  • Behets J, Declerck P, Delaedt Y, et al. (2007). Development and evaluation of a Taqman duplex real-time PCR quantification method for reliable enumeration of Legionella pneumophila in water samples. J Microbiol Meth 68:137–44
  • Benkel DH, McClure EM, Woolard D, et al. (2000). Outbreak of Legionnaires' disease associated with a display whirlpool spa. Int J Epidemiol 29:1092–8
  • Bonetta S, Bonetta S, Ferretti E, et al. (2010). Evaluation of Legionella pneumophila contamination in Italian hotel water systems by quantitative real-time PCR and culture methods. J Appl Microbiol 108:1576–83
  • Bopp CA, Sumner JW, Morris GK, Wells JG. (1981). Isolation of Legionella spp. from environmental water samples by low-pH treatment and use of a selective medium. J Clin Microbiol 13:714–19
  • Borges A, Simões M, Martínez-Murcia A, Saavedra M. (2012). Detection of Legionella spp. in natural and man-made water systems using standard guidelines. J Microbiol Res 2:95–102
  • Brooks T, Osicki R, Springthorpe V, et al. (2004). Detection and identification of Legionella species from groundwaters. J Toxicol Environ Health Part A 67:1845–59
  • Carvalho FS, Vazoller R, Foronda A, Pellizari V. (2007). Phylogenetic study of Legionella species in pristine and polluted aquatic samples from a tropical Atlantic forest ecosystem. Curr Microbiol 55:288–93
  • Casati S, Gioria-Martinoni A, Gaia V. (2009). Commercial potting soils as an alternative infection source of Legionella pneumophila and other Legionella species in Switzerland. Clin Microbiol Infection 15:571–5
  • CDC. (2005). Procedures for the recovery of Legionella from the environment. Atlanta: Centers for Disease Control and Prevention
  • Chang B, Sugiyama K, Taguri T, et al. (2009). Specific detection of viable Legionella cells by combined use of photoactivated ethidium monoazide and PCR/real-time PCR. Appl Environ Microbiol 75:147–53
  • Chang CW, Hwang YH, Cheng WY, Chang CP. (2007). Effects of chlorination and heat disinfection on long-term starved Legionella pneumophila in warm water. J Appl Microbiol 102:1636–44
  • Chen NT, Chang CW. (2010). Rapid quantification of viable Legionellae in water and biofilm using ethidium monoazide coupled with real-time quantitative PCR. J Appl Microbiol 109:623–34
  • Cianciotto NP. (2001). Pathogenicity of Legionella pneumophila. Int J Medical Microbiol 291:331–43
  • Cooper IR, Meikle ST, Standen G, et al. (2009). The rapid and specific real-time detection of Legionella pneumophila in water samples using Optical Waveguide Lightmode Spectroscopy. J Microbiolog Meth 78:40–4
  • Cristino S, Legnani PP, Leoni E. (2012). Plan for the control of Legionella infections in long-term care facilities: role of environmental monitoring. Int J Hygiene Environ Health 215:279–85
  • Declerck P, Behets J, Lammertyn E, et al. (2006). Detection and quantification of Legionella pneumophila in water samples using competitive PCR. Can J Microbiol 52:584–90
  • Delgado-Viscogliosi P, Solignac L, Delattre J-M. (2009). Viability PCR, a culture-independent method for rapid and selective quantification of viable Legionella pneumophila cells in environmental water samples. Appl Environ Microbiol 75:3502–12
  • Deloge Abarkan M, Deloge Abarkan T-L, Ha E, et al. (2007). Detection of airborne Legionella while showering using liquid impingement and fluorescent in situ hybridization (FISH). J Environ Monitor 9:91--7
  • Devos L, Clymans K, Boon N, Verstraete W. (2005). Evaluation of nested PCR assays for the detection of Legionella pneumophila in a wide range of aquatic samples. J Appl Microbiol 99:916–25
  • Diederen CMA, de Jong I, Aarts M, et al. (2007). Molecular evidence for the ubiquitous presence of Legionella species in Dutch tap water installations. J Water Health 5:375--83
  • Edagawa A, Kimura A, Doi H, et al. (2008). Detection of culturable and nonculturable Legionella species from hot water systems of public buildings in Japan. J Appl Microbiol 105:2104–14
  • Feeley JC, Gibson RJ, Gorman GW, et al. (1979). Charcoal-yeast extract agar: primary isolation medium for Legionella pneumophila. J Clin Microbiol 10:437–41
  • Fields BS, Benson RF, Besser RE. (2002). Legionella and Legionnaires’ disease: 25 years of investigation. Clin Microbiol Rev 15:506–26
  • Fittipaldi M, Codony F, Adrados B, et al. (2011). Viable real-time PCR in environmental samples: can all data be interpreted directly? Microbial Ecol 61:7–12
  • Fittipaldi M, Codony F, Morato J. (2010). Comparison of conventional culture and real-time quantitative PCR using SYBR Green for detection of Legionella pneumophila in water samples. Water SA 36:417–24
  • Fiume L, Bucca Sabattini MA, Poda G. (2005). Detection of Legionella pneumophila in water samples by species-specific real-time and nested PCR assays. Lett Appl Microbiol 41:470–5
  • Flekna G, Štefanič P, Wagner M, et al. (2007). Insufficient differentiation of live and dead Campylobacter jejuni and Listeria monocytogenes cells by ethidium monoazide (EMA) compromises EMA/real-time PCR. Res Microbiol 158:405–12
  • Fliermans CB, Cherry WB, Orrison LH, et al. (1981). Ecological distribution of Legionella pneumophila. Appl Environ Microbiol 41:9–16
  • García MT, Jones S, Pelaz C, et al. (2007). Acanthamoeba polyphaga resuscitates viable non-culturable Legionella pneumophila after disinfection. Environ Microbiol 9:1267–77
  • Goetz AM, Stout JE, Jacobs SL, et al. (1998). Nosocomial Legionnaires’ disease discovered in community hospitals following cultures of the water system: seek and ye shall find. Am J Infection Control 26:8–11
  • Guillemet TA, Lévesque B, Gauvin D, et al. (2010). Assessment of real-time PCR for quantification of Legionella spp. in spa water. Lett Appl Microbiol 51:639–44
  • Haupt TEMS, Heffernan RTMPH, Kazmierczak JJDVM, et al. (2012). An outbreak of legionnaires disease associated with a decorative water wall fountain in a hospital. Infection Control Hospital Epidemiol 33:185–91
  • Hein I, Flekna G, Wagner M. (2006). Possible errors in the interpretation of ethidium bromide and picogreen DNA staining results from ethidium monoazide-treated DNA. Appl Environm Microbiol 72:6860–2
  • Hsu B-M, Lin C-L, Shih F-C. (2009). Survey of pathogenic free-living amoebae and Legionella spp. in mud spring recreation area. Water Res 43:2817–28
  • Huang S-W, Hsu B-M, Chen N-H, et al. (2011a). Isolation and identification of Legionella and their host amoebae from weak alkaline carbonate spring water using a culture method combined with PCR. Parasitol Res 109:1233–41
  • Huang S-W, Hsu B-M, Huang C-C, Chen J-S. (2011b). Utilization of polymerase chain reaction and selective media cultivation to identify Legionella in Taiwan spring water samples. Environ Monitor Assess 174:427–37
  • Joly P, Falconnet, P-A, Andre J, et al. (2006). Quantitative real-time Legionella PCR for environmental water samples: data interpretation. Appl Environ Microbiol 72:2801–8
  • Josephson KL, Gerba CP, Pepper IL. (1993). Polymerase chain reaction detection of nonviable bacterial pathogens. Appl Environ Microbiol 59:3513–15
  • Khweek A, Dávila NF, Caution K, et al. (2013). Biofilm-derived Legionella pneumophila evades the innate immune response in macrophages. Cellular Infect Microbiol 3:18–26
  • Kim BR, Anderson JE, Mueller SA, et al. (2002). Literature review – efficacy of various disinfectants against Legionella in water systems. Water Res 36:4433–44
  • Klont RR, Rijs AJM, Warris A, et al. (2006). Legionella pneumophila in commercial bottled mineral water. FEMS Immunol Medical Microbiol 47:42–4
  • Kobayashi H, Oethinger M, Tuohy MJ, et al. (2009). Unsuitable distinction between viable and dead Staphylococcus aureus and Staphylococcus epidermidis by ethidium bromide monoazide. Lett Appl Microbiol 48:633–8
  • Krøjgaard L, Krogfelt K, Albrechtsen H-J, Uldum S. (2011). Detection of Legionella by quantitative-polymerase chain reaction (qPCR) for monitoring and risk assessment. BMC Microbiol 11:254
  • La Scola B, Mezi L, Weiller PJ, Raoult D. (2001). Isolation of Legionella anisa using an amoebic coculture procedure. J Clin Microbiol 39:365–6
  • Lee JV, Lai S, Exner M, et al. (2011). An international trial of quantitative PCR for monitoring Legionella in artificial water systems. J Appl Microbiol 110:1032–44
  • Leoni E, De Luca G, Legnani PP, et al. (2005). Legionella waterline colonization: detection of Legionella species in domestic, hotel and hospital hot water systems. J Appl Microbiol 98:373–9
  • Leoni E, Legnani PP. (2001). Comparison of selective procedures for isolation and enumeration of Legionella species from hot water systems. J Appl Microbiol 90:27–33
  • Levi K, Smedley J, Towner KJ. (2003). Evaluation of a real-time PCR hybridization assay for rapid detection of Legionella pneumophila in hospital and environmental water samples. Clin Microbiol Infect 9:754–8
  • Mahbubani MH, Bej AK, Miller R, et al. (1990). Detection of Legionella with polymerase chain reaction and gene probe methods. Molec Cell Probes 4:175–87
  • McCoy WF, Downes EL, Leonidas LF, et al. (2012). Inaccuracy in Legionella tests of building water systems due to sample holding time. Water Res 46:3497–506
  • Miranda-Castro R, de-los-Santos-Álvarez P, et al. (2007). Hairpin-DNA probe for enzyme-amplified electrochemical detection of Legionella pneumophila. Anal Chem 79:4050–5
  • Morio F, Corvec S, Caroff N, et al. (2008). Real-time PCR assay for the detection and quantification of Legionella pneumophila in environmental water samples: utility for daily practice. Int J Hygiene Environ Health 211:403–11
  • Morrill WE, Barbaree J, Fields B, et al. (1990). Increased recovery of Legionella micdadei and Legionella bozemanii on buffered charcoal yeast extract agar supplemented with albumin. J Clin Microbiol 28:616–18
  • Murga R, Forster TS, Brown E, et al. (2001). Role of biofilms in the survival of Legionella pneumophila in a model potable-water system. Microbiology 147:3121–6
  • Nazarian EJ, Bopp DJ, Saylors A, et al. (2008). Design and implementation of a protocol for the detection of Legionella in clinical and environmental samples. Diagn Microbiol Infect Dis 62:125–32
  • Neil K, Berkelman R. (2008). Increasing incidence of Legionellosis in the United States, 1990–2005: changing epidemiologic trends. Clin Infect Dis 47:591–9
  • Nhu Nguyen TM, Ilef D, Jarraud S, et al. (2006). A community-wide outbreak of Legionnaires disease linked to industrial cooling towers – how far can contaminated aerosols spread? J Infect Dis 193:102–11
  • Nocker A, Sossa-Fernandez P, Burr MD, Camper AK. (2007). Use of propidium monoazide for live/dead distinction in microbial ecology. Appl Environ Microbiol 73:5111–17
  • O’Connor B, Carman A, Eckert K, et al. (2007). Does using potting mix make you sick? Results from a Legionella longbeachae case-control study in South Australia. Epidemiol Infect 135:34–9
  • Oh B-K, Kim Y-K, Lee W, et al. (2003). Immunosensor for detection of Legionella pneumophila using surface plasmon resonance. Biosens Bioelectron 18:605–11
  • Parthuisot N, West NJ, Lebaron P, Baudart J. (2010). High diversity and abundance of Legionella spp. in a Pristine river and impact of seasonal and anthropogenic effects. Appl Environ Microbiol 76:8201–10
  • Pendland SL, Martin SJ, Chen C, et al. (1997). Comparison of charcoal- and starch-based media for testing susceptibilities of Legionella species to macrolides, azalides, and fluoroquinolones. J Clin Microbiol 35:3004–6
  • Pine L, George JR, Reeves MW, Harrell WK. (1979). Development of a chemically defined liquid medium for growth of Legionella pneumophila. J Clin Microbiol 9:615–26
  • Pisz JM, Lawrence JR, Schafer AN, Siciliano SD. (2007). Differentiation of genes extracted from non-viable versus viable micro-organisms in environmental samples using ethidium monoazide bromide. J Microbiol Meth 71:312–18
  • Qasem JA, Mustafa AS, Khan ZU. (2008). Legionella in clinical specimens and hospital water supply facilities: molecular detection and genotyping of the isolates. Med Principles Pract 17:49–55
  • Qin T, Tian Z, Ren H, et al. (2012). Application of EMA-qPCR as a complementary tool for the detection and monitoring of Legionella in different water systems. World J Microbiol Biotechnol 28:1881–90
  • Reeves MW, Pine L, Hutner SH, et al. (1981). Metal requirements of Legionella pneumophila'. J Clin Microbiol 13:688–95
  • Roberts KP, August CM, Nelson Jr JD. (1987). Relative sensitivities of environmental Legionellae to selective isolation procedures. Appl Environ Microbiol 53:2704–7
  • Rogers J, Dowsety AB, Dennis PJ, et al. (1994). Influence of plumbing materials on biofilm formation and growth of Legionella pneumophila in potable water systems. Appl Environ Microbiol 60:1842–51
  • Rowbotham TJ. (1983). Isolation of Legionella pneumophila from clinical specimens via amoebae, and the interaction of those and other isolates with amoebae. J Clin Pathol 36:978–86
  • Sathapatayavongs B, Kohler R, Wheat L, et al. (1983). Rapid diagnosis of Legionnaires' disease by latex agglutination. Am Rev Respiratory Dis 127:559--62
  • Shih H-Y, Lin YE. (2006). Caution on interpretation of Legionella results obtained using real-time PCR for environmental water samples. Appl Environ Microbiol 72:6859
  • Steele TW. (1990). Distribution of Legionella longbeachae serogroup 1 and other Legionellae in potting soils in Australia. Appl Environ Microbiol 56:2984--8
  • Steele TW, Moore CV, Sangster N. (1990). Distribution of Legionella longbeachae serogroup 1 and other Legionellae in potting soils in Australia. Appl Environ Microbiol 56:2984–8
  • Steinert M, Emody L, Amann R, Hacker J. (1997). Resuscitation of viable but nonculturable Legionella pneumophila Philadelphia JR32 by Acanthamoeba castellanii. Appl Environ Microbiol 63:2047–53
  • Stout JE. (1992). Legionella pneumophila in residential water supplies: environmental surveillance with clinical assessment for Legionnaires' disease. Epidemiol Infect 109:45--57
  • Ta AC, Stout JE, Yu VL, Wagener MM. (1995). Comparison of culture methods for monitoring Legionella species in hospital potable water systems and recommendations for standardization of such methods. J Clin Microbiol 33:2118–23
  • Templeton KE, Scheltinga SA, Sillekens P, et al. (2003). Development and clinical evaluation of an internally controlled, single-tube multiplex real-time PCR assay for detection of Legionella pneumophila and other Legionella species. J Clin Microbiol 41:4016–21
  • Thomas V, Bouchez T, Nicolas V, et al. (2004). Amoebae in domestic water systems: resistance to disinfection treatments and implication in Legionella persistence. J Appl Microbiol 97:950–63
  • Touron-Bodilis A, Pougnard C, Frenkiel-Lebossé H, Hallier-Soulier S. (2011). Usefulness of real-time PCR as a complementary tool to the monitoring of Legionella spp., Legionella pneumophila by culture in industrial cooling systems. J Appl Microbiol 111:499–510
  • Tung M-C, Chang T-Y, Hsu B-M, et al. (2013). Seasonal distribution of Legionella spp., L. pneumophila in a river in Taiwan evaluated with culture-confirmed and direct DNA extraction methods. J Hydrol 496:100–6
  • Wadowsky RM, Yee R. (1981). Glycine-containing selective medium for isolation of Legionellaceae from environmental specimens. Appl Environ Microbiol 42:768–72
  • Wang H, Edwards M, Falkinham JO, Pruden A. (2012). Molecular survey of the occurrence of Legionella spp., Mycobacterium spp., Pseudomonas aeruginosa, and amoeba hosts in two chloraminated drinking water distribution systems. Appl Environ Microbiol 78:6285–94
  • Warren WJ, Miller RD. (1979). Growth of Legionnaires disease bacterium (Legionella pneumophila) in chemically defined medium. J Clin Microbiol 10:50–5
  • Wellinghausen N, Frost C, Marre R. (2001). Detection of Legionellae in hospital water samples by quantitative real-time lightcycler PCR. Appl Environ Microbiol 67:3985–93
  • Wilson I. (1997). Inhibition and facilitation of nucleic acid amplification. Appl Environ Microbiol 63:3741–51
  • Wullings BA, Bakker G, van der Kooij D. (2011). Concentration and diversity of uncultured Legionella spp. in two unchlorinated drinking water supplies with different concentrations of natural organic matter. Appl Environ Microbiol 77:634–41
  • Wullings BA, van der Kooij D. (2006). Occurrence and genetic diversity of uncultured Legionella spp. in drinking water treated at temperatures below 15 °C. Appl Environ Microbiol 72:157–66
  • Yáñez MA, Barberá VM, Catalán V. (2007). Validation of a new seminested PCR-based detection method for Legionella pneumophila. J Microbiolog Meth 70:214–17
  • Yáñez MA, Carrasco-Serrano C, Barberá VM, Catalán V. (2005). Quantitative detection of Legionella pneumophila in water samples by immunomagnetic purification and real-time PCR amplification of the dotA gene. Appl Environ Microbiol 71:3433–41
  • Yáñez MA, Nocker A, Soria-Soria E, et al. (2011). Quantification of viable Legionella pneumophila cells using propidium monoazide combined with quantitative PCR. J Microbiol Meth 85:124–30
  • Yaradou DF, Hallier-Soulier S, Moreau S, et al. (2007). Integrated real-time PCR for detection and monitoring of Legionella pneumophila in water systems. Appl Environ Microbiol 73:1452–6
  • Yasmon A, Yusmaniar J, Karuniawati A, Bela B. (2010). Simultaneous detection of Legionella species and Legionella pneumophila by duplex PCR (dPCR) assay in cooling tower water samples from Jakarta, Indonesia. Med J Indonesia 19:223–7