References
- Ai, H. M., Wu, S. C., Zhao, L., et al. (2009). Key technologies and hot issues in microwave hyperthermia. J. Clin. Rehabil. Tissue Eng. Res. 13:731–734
- Christensen, D., Durney, C. (1981). Hyperthermia production for cancer therapy: A review of fundamentals and methods. J. Microwave Power. 16:89–105
- Ebara, M., Ohto, M., Sugiura, N., et al. (1990). Percutaneous ethanol injection for the treatment of small hepatocellular carci-noma study of 95 patients. J. Gastroenterol. Hepatol. 5:616–626
- Godlewsdi, G., Rowy, S., Pigmodei, C., et al. (1988). Deep localized Neodymium (ND)-YAG laser photocoagulation on liver using a new water cooled and echoguided handpiece. Lasers Surg. Med. 8:501–509
- Goldberg, S. N., Gazelle, G. S., Mueller, P. R. (2000). Thermal ablation therapy for focal malignancy: A unified approach to underlying principles, techniques, and diagnostic imaging guidance. Am. J. Roentgenol. 174:323–331
- Gu, Z., Rappaport, M., Wang, P. J., VanderBrink, B. A. (2000). Development and experimental verification of the wide-aperture catheter-based microwave cardiac ablation antenna. IEEE. Trans. Microwave Theory Tech. 48:1892–1900
- Ji, Z., Brace, C. L. (2011). Expanded modelling of temperature-dependent dielectric properties for microwave thermal ablation. Phys. Med. Biol. 56:5249–5264
- Jiang, H. B., Hao, J., Li, A. H. (1992). Microwave phantom muscle tissue. Chin. J. Biomed. Eng. 11:199–203
- Kang, Y. X., Zhang, H. L. (2008). The research progress of tumor heat treatment mechanism. J. Med. Oncol. 16:473–475
- Kasevich, R. S., Mcqueeney, J. F., Crooker, R. H. (1991). Microwave balloon angioplasty. US Patent 5,057,106
- Labonte, S., Ali, H., Roy, L. (1995). Monopoles for microwave catheter ablation of heart tissue. IEEE MTT SYMP. Dig. 1:303–306
- Langberg, J., Chin, M. C., Griffin, J. C., et al. (1991). Ablation of atrioventricular junction using radiofrequency energy using a new electrode catheter. Am. J. Cardiol. 67:142–147
- Li, W. J., Hao, J. (2003). Preparation of microwave phantom and its specific dielectric properties. Chin. J. Biomed. Eng. 22:79–82
- Li, X., Zhang, L., Fan, W. J., et al. (2011). Comparison of microwave ablation and multipolar radiofrequency ablation, both using a pair of internally cooled interstitial applicators: Results in ex vivo porcine livers. Int. J. Hyperthermia. 27:240–248
- Liang, P., Dong, B. W., Yu, X. L., et al. (2002). In vitro simulation and verification of implanted microwave thermal distribution in pig liver. Chin. J. Med. Imag. 10:197–199
- Liu, F. Y., Yu, X. L., Han, Z. Y., Wang, Y. (2008). Clinical application of ultrasound-guided percutaneous biopsy in mediastinal lesions. Chin. J. Med. Imag. Tech. 24:1459–1461
- Liu, F. Y., Yu, X. L., Liang, P., et al. (2009). Comparison of implanted cooled-shaft 915 MHz and 2450 MHz microwave ablation of in vivo porcine livers. Chin. J. Med. Imag. Tech. 25:1765–1768
- Liu, P., Rappaport, C. (1996). Microwave assisted balloon angioplasty. IEEE Trans. Microwave Theory Tech. 44:1819–1831
- Liu, Y. J., Yang, X. Y., Nan, Q., et al. (2007). Phantom experimental study on microwave ablation with water-cooled antenna. Int. J. Hyperthermia. 23:381–386
- Lopresto, V., Pinto, R., Lovisolo, G. A., Cavagnaro, M. (2012). Changes in the dielectric properties of ex vivo bovine liver during microwave thermal ablation at 2.45 GHz. Phys. Med. Biol. 57:2309–2327
- Lu, Y. L., Nan, Q., Du, J. J., Li, L., et al. (2010). Experimental study on thermal field in the vicinity of arterial bifurcation in microwave ablation therapy. Int. J. Hyperthermia. 26:316–326
- Qu, B., Chen, X. L., Wang, Z. Y., et al. (2003). Thermocouple device for temperature measurement used in the microwave diathermy apparatus. J. Transducer. Tech. 22:29–31
- Rosen, A., Wallinski, P., Smith, D., et al. (1990). Percutaneous transluminal microwave balloon angioplasty. IEEE Trans. Microwave Theory Tech. 38:90–93
- Ryan, T. P., Turner, P. F., Hamilton, B. (2010). Interstitial microwave transition from hyperthermia to ablation: Historical perspectives and current trends in thermal therapy. Int. J. Hyperthermia 26:415–433
- Seki, T., Nonaka, T., Kubota, Y., et al. (1989). Ultrasonically guided percutaneous ethanol injection therapy for hepatocellular carcinoma. Am. J. Gastorenterol. 84:1400–1407
- Seki, T., Wakabayashi, M., Nakagawa, T., et al. (1999). Percutaneous microwave coagulation therapy for patients with small hepatocellular carcinoma. Cancer. 85:1694–1702
- Stone, H. B., Dewey, W. C. (1987). Biologic basis and clinical potential of local-regional hyperthermia. In: Phillips, T. L. Radiation Oncology. Vol. 2. New York: Raven Press. pp. 1–2
- Szwarnowski, S., Sheppard, R. J., Grant, E. H., Bleehen, N. M. (1980). A thermocouple for measuring temperature biological mate-rial heated by microwaves at 2.45 GHz. Br. J. Radiol. 53:711–715
- Yu, Z. C., Liu, W. C., Fan, L., et al. (2009). The efficacy and safety of percutaneous microwave coagulation by a new microwave delivery system in large hepatocellular carcinomas: Four case studies. Int. J. Hyperthermia. 25:392–398
- Zhao, L., Sheng, X. J., Wu, S. C., et al. (2009). Effect of thermal properties of biologic tissue during microware hyperthermia. China Med. Dev. 24:15–22