990
Views
6
CrossRef citations to date
0
Altmetric
Hip and knee

Retrieval analysis of alumina ceramic-on-ceramic bearing couples

, , &
Pages 133-140 | Received 24 Apr 2013, Accepted 09 Dec 2013, Published online: 20 Mar 2014

  • Affatato S, Traina F, De Fine M, Carmignato S, Toni A. Alumina-on-alumina hip implants: A wear study of retrieved components. J Bone Joint Surg (Br) 2012; 94 (1): 37–42.
  • Boutin P, Christel P, Dorlot JM, Meunier A, de Roquancourt A, Blanquaert D, et al. The use of dense alumina-alumina ceramic combination in total hip replacement. J Biomed Mater Res 1988; 22 (12): 1203–32.
  • Dowson D. New joints for the Millennium: wear control in total replacement hip joints. Proc Inst Mech Eng H 2001; 215 (4): 335–58.
  • Hannouche D, Zaoui A, Zadegan F, Sedel L, Nizard R. Thirty years of experience with alumina-on-alumina bearings in total hip arthroplasty. Int Orthop 2011; 35 (2): 207–13.
  • Jeffers J RT, Walter WL. Ceramic-on-ceramic bearings in hip arthroplasty: state of the art and the future. J Bone Joint Surg (Br) 2012; 94 (6): 735–45.
  • Mabuchi K, Sakai R, Ota M, Ujihira M. Appropriate radial clearance of ceramic-on-ceramic total hip prostheses to realize squeeze-film lubrication. Clin Biomech (Bristol. Avon) 2004; 19 (4): 362–9.
  • Mittelmeier H, Heisel J. Sixteen-years’ experience with ceramic hip prostheses. Clin Orthop 1992; (282): 64–72.
  • Nevelos JE, Ingham E, Doyle C, Fisher J, Nevelos AB. Analysis of retrieved alumina ceramic components from Mittelmeier total hip prostheses. Biomaterials 1999; 20 (19): 1833–40.
  • Nevelos JE, Prudhommeaux F, Hamadouche M, Doyle C, Ingham E, Meunier A, et al. Comparative analysis of two different types of alumina-alumina hip prosthesis retrieved for aseptic loosening. J Bone Joint Surg (Br) 2001; 83 (4): 598–603.
  • Nizard R, Sedel L, Hannouche D, Hamadouche M, Bizot P. Alumina pairing in total hip replacement. J Bone Joint Surg (Br) 2005; 87 (6): 755–8.
  • Prudhommeaux F, Hamadouche M, Nevelos J, Doyle C, Meunier A, Sedel L. Wear of alumina-on-alumina total hip arthroplasties at a mean 11-year followup. Clin Orthop 2000; (379): 113–22.
  • Rieker C, Konrad R, Schön R. In vitro comparison of the two hard-hard articulations for total hip replacements. Proc Inst Mech Eng H 2001; 215 (2): 153–60.
  • Savarino L, Baldini N, Ciapetti G, Pellacani A, Giunti A. Is wear debris responsible for failure in alumina-on-alumina implants? Acta Orthop 2009; 80 (2): 162–7.
  • Scholes SC, Unsworth A. Comparison of friction and lubrication of different hip prostheses. Proc Inst Mech Eng H 2000; 214 (1): 49–57.
  • Scholes SC, Unsworth A. The effects of proteins on the friction and lubrication of artificial joints. Proc Inst Mech Eng H 2006; 220 (6): 687–93.
  • Sedel L. Evolution of Alumina-on-Alumina Implants. Clin Orthop 2000; (379): 48–54.
  • Stewart TD, Tipper JL, Insley G, Streicher RM, Ingham E, Fisher J. Long-term wear of ceramic matrix composite materials for hip prostheses under severe swing phase microseparation. J Biomed Mater Res B Appl Biomater 2003; 66 (2): 567–73.
  • Tateiwa T, Clarke IC, Williams PA, Garino J, Manaka M, Shishido T, et al. Ceramic total hip arthroplasty in the United States: safety and risk issues revisited. Am J Orthop (Belle Mead NJ) 2008; 37 (2): E26–31.
  • Tipper JL, Hatton A, Nevelos JE, Ingham E, Doyle C, Streicher R, et al. Alumina-alumina artificial hip joints. Part II: characterisation of the wear debris from in vitro hip joint simulations. Biomaterials 2002; 23 (16): 3441–8.
  • Unsworth A. The effects of lubrication in hip joint prostheses. Phys Med Biol 1978; 23 (2): 253–68.
  • Yoon TR, Rowe SM, Jung ST, Seon KJ, Maloney WJ. Osteolysis in association with a total hip arthroplasty with ceramic bearing surfaces. J Bone Joint Surg (Am) 1998; 80 (10): 1459–68.
  • Zecchino M. Characterising surface quality. Why average roughness is not enough. [Internet]. Veeco Instruments Inc. 2003. Available from: http://www.veeco.com/pdfs/appnotes/an511_roughness_64.pdf