- Affatato S, Traina F, De Fine M, Carmignato S, Toni A. Alumina-on-alumina hip implants: A wear study of retrieved components. J Bone Joint Surg (Br) 2012; 94 (1): 37–42.
- Boutin P, Christel P, Dorlot JM, Meunier A, de Roquancourt A, Blanquaert D, et al. The use of dense alumina-alumina ceramic combination in total hip replacement. J Biomed Mater Res 1988; 22 (12): 1203–32.
- Dowson D. New joints for the Millennium: wear control in total replacement hip joints. Proc Inst Mech Eng H 2001; 215 (4): 335–58.
- Hannouche D, Zaoui A, Zadegan F, Sedel L, Nizard R. Thirty years of experience with alumina-on-alumina bearings in total hip arthroplasty. Int Orthop 2011; 35 (2): 207–13.
- Jeffers J RT, Walter WL. Ceramic-on-ceramic bearings in hip arthroplasty: state of the art and the future. J Bone Joint Surg (Br) 2012; 94 (6): 735–45.
- Mabuchi K, Sakai R, Ota M, Ujihira M. Appropriate radial clearance of ceramic-on-ceramic total hip prostheses to realize squeeze-film lubrication. Clin Biomech (Bristol. Avon) 2004; 19 (4): 362–9.
- Mittelmeier H, Heisel J. Sixteen-years’ experience with ceramic hip prostheses. Clin Orthop 1992; (282): 64–72.
- Nevelos JE, Ingham E, Doyle C, Fisher J, Nevelos AB. Analysis of retrieved alumina ceramic components from Mittelmeier total hip prostheses. Biomaterials 1999; 20 (19): 1833–40.
- Nevelos JE, Prudhommeaux F, Hamadouche M, Doyle C, Ingham E, Meunier A, et al. Comparative analysis of two different types of alumina-alumina hip prosthesis retrieved for aseptic loosening. J Bone Joint Surg (Br) 2001; 83 (4): 598–603.
- Nizard R, Sedel L, Hannouche D, Hamadouche M, Bizot P. Alumina pairing in total hip replacement. J Bone Joint Surg (Br) 2005; 87 (6): 755–8.
- Prudhommeaux F, Hamadouche M, Nevelos J, Doyle C, Meunier A, Sedel L. Wear of alumina-on-alumina total hip arthroplasties at a mean 11-year followup. Clin Orthop 2000; (379): 113–22.
- Rieker C, Konrad R, Schön R. In vitro comparison of the two hard-hard articulations for total hip replacements. Proc Inst Mech Eng H 2001; 215 (2): 153–60.
- Savarino L, Baldini N, Ciapetti G, Pellacani A, Giunti A. Is wear debris responsible for failure in alumina-on-alumina implants? Acta Orthop 2009; 80 (2): 162–7.
- Scholes SC, Unsworth A. Comparison of friction and lubrication of different hip prostheses. Proc Inst Mech Eng H 2000; 214 (1): 49–57.
- Scholes SC, Unsworth A. The effects of proteins on the friction and lubrication of artificial joints. Proc Inst Mech Eng H 2006; 220 (6): 687–93.
- Sedel L. Evolution of Alumina-on-Alumina Implants. Clin Orthop 2000; (379): 48–54.
- Stewart TD, Tipper JL, Insley G, Streicher RM, Ingham E, Fisher J. Long-term wear of ceramic matrix composite materials for hip prostheses under severe swing phase microseparation. J Biomed Mater Res B Appl Biomater 2003; 66 (2): 567–73.
- Tateiwa T, Clarke IC, Williams PA, Garino J, Manaka M, Shishido T, et al. Ceramic total hip arthroplasty in the United States: safety and risk issues revisited. Am J Orthop (Belle Mead NJ) 2008; 37 (2): E26–31.
- Tipper JL, Hatton A, Nevelos JE, Ingham E, Doyle C, Streicher R, et al. Alumina-alumina artificial hip joints. Part II: characterisation of the wear debris from in vitro hip joint simulations. Biomaterials 2002; 23 (16): 3441–8.
- Unsworth A. The effects of lubrication in hip joint prostheses. Phys Med Biol 1978; 23 (2): 253–68.
- Yoon TR, Rowe SM, Jung ST, Seon KJ, Maloney WJ. Osteolysis in association with a total hip arthroplasty with ceramic bearing surfaces. J Bone Joint Surg (Am) 1998; 80 (10): 1459–68.
- Zecchino M. Characterising surface quality. Why average roughness is not enough. [Internet]. Veeco Instruments Inc. 2003. Available from: http://www.veeco.com/pdfs/appnotes/an511_roughness_64.pdf
Acta Orthopaedica
Volume 85, 2014 - Issue 2
Open access
991
Views
6
CrossRef citations to date
0
Altmetric
Hip and knee
Retrieval analysis of alumina ceramic-on-ceramic bearing couples
Muhammad KorimUniversity Hospitals of Leicester, Leicester General Hospital,
LeicesterCorrespondence[email protected]
, Susan ScholesSchool of Mechanical and Systems Engineering,
Newcastle University, Newcastle
, Anthony UnsworthSchool of Engineering and Computing Sciences,
Durham University, Durham, UK.
& Richard PowerUniversity Hospitals of Leicester, Leicester General Hospital,
Leicester
Pages 133-140
|
Received 24 Apr 2013, Accepted 09 Dec 2013, Published online: 20 Mar 2014
Related research
People also read lists articles that other readers of this article have read.
Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.
Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.