- Akbarnia BA, Mundis G M Jr, Salari P, Yaszay B, Pawelek JB. Innovation in growing rod technique: a study of safety and efficacy of a magnetically controlled growing rod in a porcine model. Spine 2012; 37: 1109–14.
- Burghardt RD, Herzenberg JE, Specht SC, Paley D. Mechanical failure of the Intramedullary Skeletal Kinetic Distractor in limb lengthening. J Bone Joint Surg (Br) 2011; 93: 639–43.
- Cheung KM, Cheung JP, Samartzis D. Magnetically controlled growing rods for severe spinal curvature in young children: a prospective case series. Lancet 2012; 379: 1967–74.
- Cole JD, Justin D, Kasparis T, DeVlught D, Knobloch C. The intramedullary skeletal kinetic distractor (ISKD): first clinical results of a new intramedullary nail for lengthening of the femur and tibia. Injury (Suppl 4) 2001; 32: SD129–39.
- Ellipse Inc., Irvine, California, USA. Remote control technology for the treatment of limb length discrepancies: PRECICE®. Available at: http://www.ellipse-tech.com/pages/PRECICE (accessed 25 May 2013).
- Kenawey M, Krettek C, Liodakis E, Wiebking U, Hankemeier S. Leg lengthening using intramedullary skeletal kinetic distractor: results of 57 consecutive applications. Injury 2011; 42: 150–5.
- Mahboubian S, Seah M, Fragomen AT, Rozbruch SR. Femoral lengthening with lengthening over a nail has fewer complications than intramedullary skeletal kinetic distraction. Clin Orthop 2012; (470): 1221–31.
- Paley D. Problems, obstacles, and complications of limb lengthening by the Ilizarov technique. Clin Orthop 1990; (250): 81–104.
- Papanna MC, Monga P, Al-Hadithy N, Wilkes RA. Promises and difficulties with the use of femoral intra-medullary lengthening nails to treat limb length discrepancies. Acta Orthop Belg 2011; 77: 788–94.
- Schiedel FM, Pip S, Wacker S, Pöpping J, Leidinger B, Rödl R. Intramedullary limb lengthening with the Intramedullary Skeletal Kinetic Distractor in the lower limb. J Bone Joint Surg (Br) 2011; 93: 788–92.
- Simpson AH, Shalaby H, Keenan G. Femoral lengthening with the Intramedullary Skeletal Kinetic Distractor. J Bone Joint Surg (Br) 2009; 91: 955–61.
- Thonse R, Herzenberg JE, Standard SC. Limb lengthening with a fully implantable, telescopic, intramedullary nail. Oper Tech Orthop 2005; 15: 355–62.
- Wang K, Edwards E. Intramedullary skeletal kinetic distractor in the treatment of leg length discrepancy—a review of 16 cases and analysis of complications. J Orthop Trauma 2012; 26: e138–44.
Acta Orthopaedica
Volume 85, 2014 - Issue 3
Open access
2,921
Views
109
CrossRef citations to date
0
Altmetric
Lower leg
How precise is the PRECICE compared to the ISKD in intramedullary limb lengthening?
Reliability and safety in 26 procedures
Frank M Schiedel Department of Pediatric Orthopedics, Deformity Correction and Foot SurgeryCorrespondence[email protected]
, Björn Vogt Department of Pediatric Orthopedics, Deformity Correction and Foot Surgery
, Henning L Tretow Department of Pediatric Orthopedics, Deformity Correction and Foot Surgery
, Britta SchuhknechtDepartment of Orthopedics and Tumor Orthopedics,
Münster University Hospital, Münster, Germany.
, Georg GoshegerDepartment of Orthopedics and Tumor Orthopedics,
Münster University Hospital, Münster, Germany.
, Melanie J Horter Department of Pediatric Orthopedics, Deformity Correction and Foot Surgery
& Robert Rödl Department of Pediatric Orthopedics, Deformity Correction and Foot Surgery
show all
Pages 293-298
|
Received 15 Aug 2013, Accepted 20 Feb 2014, Published online: 23 Apr 2014
Related research
People also read lists articles that other readers of this article have read.
Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.
Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.