1,866
Views
23
CrossRef citations to date
0
Altmetric
Hip and pelvis

Metal release and metal allergy after total hip replacement with resurfacing versus conventional hybrid prosthesis

5-year follow-up of 52 patients

, , , , , , , & show all
Pages 348-354 | Received 27 May 2013, Accepted 07 Mar 2014, Published online: 16 Jun 2014

  • Baad-Hansen T, Storgaard Jakobsen S, Soballe K. Two-year migration results of the ReCap hip resurfacing system-a radiostereometric follow-up study of 23 hips. Int Orthop 2011; 35 (4): 497-502.
  • Benson MK, Goodwin PG, Brostoff J. Metal sensitivity in patients with joint replacement arthroplasties. Br Med J 1975; 4 (5993): 374-5.
  • Chan FW, Bobyn JD, Medley JB, Krygier JJ, Tanzer M. The otto aufranc award. wear and lubrication of metal-on-metal hip implants. Clin Orthop 1999; (369): 10-24.
  • Coleman RF, Herrington J, Scales JT. Concentration of wear products in hair, blood, and urine after total hip replacement. Br Med J 1973; 1 (5852): 527-9.
  • Corr SC, O’Neill LA. Genetic variation in toll-like receptor signalling and the risk of inflammatory and immune diseases. J Innate Immun 2009; 1 (4): 350-7.
  • Cousen PJ, Gawkrodger DJ. Metal allergy and second-generation metal-on-metal arthroplasties. Contact Dermatitis 2012; 66 (2): 55-62.
  • Doorn PF, Campbell PA, Worrall J, Benya PD, McKellop HA, Amstutz HC. Metal wear particle characterization from metal on metal total hip replacements: Transmission electron microscopy study of periprosthetic tissues and isolated particles. J Biomed Mater Res 1998; 42 (1): 103-11.
  • Elves MW, Wilson JN, Scales JT, Kemp HB. Incidence of metal sensitivity in patients with total joint replacements. Br Med J 1975; 4 (5993): 376-8.
  • Firkins PJ, Tipper JL, Saadatzadeh MR, Ingham E, Stone MH, Farrar R, Fisher J. Quantitative analysis of wear and wear debris from metal-on-metal hip prostheses tested in a physiological hip joint simulator. Biomed Mater Eng 2001; 11 (2): 143-57.
  • Gallo J, Konttinen Y, Goodman S, Thyssen J, Gibon E, Pajarinen J, Takakubo Y, Schalock P, Mackiewicz Z, Jämsen E, Petrek M, Trebse R, Coer A, Takagi M. Aseptic loosening of total hip arthroplasty as a result of local failure of tissue homeostasis, recent advances in arthroplasty, dr. samo fokter (ed.), ISBN: 978-953-307-990-5, InTech, available from: Http://Www.intechopen.com/books/recent-advances-in-arthroplasty/aseptic-loosening-of-total- hip-arthroplasty-as-a-result-of-local-failure-of-tissue-homeostasis 2012: 319-63.
  • Gawkrodger DJ. Metal sensitivities and orthopaedic implants revisited: The potential for metal allergy with the new metal-on-metal joint prostheses. Br J Dermatol 2003; 148 (6): 1089-93.
  • Granchi D, Cenni E, Tigani D, Trisolino G, Baldini N, Giunti A. Sensitivity to implant materials in patients with total knee arthroplasties. Biomaterials 2008; 29 (10): 1494-500.
  • Grigoris P, Roberts P, Panousis K, Jin Z. Hip resurfacing arthroplasty: The evolution of contemporary designs. Proc Inst Mech Eng H 2006; 220 (2): 95-105.
  • Hallab NJ, Merritt K, Jacobs JJ. Metal sensitivity in patients with orthopaedic implants. J Bone Joint Surg (Am) 2001; 83 (3): 428-36.
  • Hallab NJ, Anderson S, Caicedo M, Skipor A, Campbell P, Jacobs JJ. Immune responses correlate with serum-metal in metal-on-metal hip arthroplasty. J Arthroplasty (Suppl 3) 2004; 19 (8): 88-93.
  • Hallab NJ, Anderson S, Stafford T, Glant T, Jacobs JJ. Lymphocyte responses in patients with total hip arthroplasty. J Orthop Res 2005; 23 (2): 384-91.
  • Jacobs JJ, Hallab NJ. Loosening and osteolysis associated with metal-on-metal bearings: A local effect of metal hypersensitivity? J Bone Joint Surg (Am) 2006; 88 (6): 1171-2.
  • Jacobs JJ, Urban RM, Hallab NJ, Skipor AK, Fischer A, Wimmer MA. Metal-on-metal bearing surfaces. J Am Acad Orthop Surg 2009; 17 (2): 69-76.
  • Kiilunen M, Jarvisalo J, Makitie O, Aitio A. Analysis, storage stability and reference values for urinary chromium and nickel. Int Arch Occup Environ Health 1987; 59 (1): 43-50.
  • Konttinen YT, Pajarinen J. Adverse reactions to metal-on-metal implants. Nat Rev Rheumatol 2013; 9 (1): 5-6.
  • Lhotka C, Szekeres T, Steffan I, Zhuber K, Zweymuller K. Four-year study of cobalt and chromium blood levels in patients managed with two different metal-on-metal total hip replacements. J Orthop Res 2003; 21 (2): 189-95.
  • MacDonald SJ, McCalden RW, Chess DG, Bourne RB, Rorabeck CH, Cleland D, Leung F. Metal-on-metal versus polyethylene in hip arthroplasty: A randomized clinical trial. Clin Orthop 2003; (406): 282-96.
  • Marco R, Katorza E, Gonen R, German U, Tshuva A, Pelled O, Paz-Tal O, Adout A, Karpas Z. Normalisation of spot urine samples to 24-h collection for assessment of exposure to uranium. Radiat Prot Dosimetry 2008; 130 (2): 213-23.
  • Marshall A, Ries MD, Paprosky W, Implant Wear Symposium 2007 Clinical Work Group. How prevalent are implant wear and osteolysis, and how has the scope of osteolysis changed since 2000? J Am Acad Orthop Surg (Suppl 1) 2008; 16: S1-6.
  • Pandit H, Glyn-Jones S, McLardy-Smith P, Gundle R, Whitwell D, Gibbons CL, Ostlere S, Athanasou N, Gill HS, Murray DW. Pseudotumours associated with metal-on-metal hip resurfacings. J Bone Joint Surg (Br) 2008; 90 (7): 847-51.
  • Petersen MK, Andersen NT, Mogensen P, Voight M, Soballe K. Gait analysis after total hip replacement with hip resurfacing implant or mallory-head exeter prosthesis: A randomised controlled trial. Int Orthop 2011; 35 (5): 667-74.
  • Potnis PA, Dutta DK, Wood SC. Toll-like receptor 4 signaling pathway mediates proinflammatory immune response to cobalt-alloy particles. Cell Immunol 2013; 282 (1): 53-65.
  • Rieker C, Kottig P. In vivo tribological performance of 231 metal-on-metal hip articulations. HIP Int 2002; 12: 73-6.
  • Schalock PC, Menne T, Johansen JD, Taylor JS, Maibach HI, Liden C, Bruze M, Thyssen JP. Hypersensitivity reactions to metallic implants–diagnostic algorithm and suggested patch test series for clinical use. Contact Dermatitis 2012; 66 (1): 4-19.
  • Scifert CF, Brown TD, Pedersen DR, Callaghan JJ. A finite element analysis of factors influencing total hip dislocation. Clin Orthop 1998; (355): 152-62.
  • Shimmin A, Beaule PE, Campbell P. Metal-on-metal hip resurfacing arthroplasty. J Bone Joint Surg (Am) 2008; 90 (3): 637-54.
  • Sieber HP, Rieker CB, Kottig P. Analysis of 118 second-generation metal-on-metal retrieved hip implants. J Bone Joint Surg (Br) 1999; 81 (1): 46-50.
  • Thienpont E, Berger Y. No allergic reaction after TKA in a chrome-cobalt-nickel-sensitive patient: Case report and review of the literature. Knee Surg Sports Traumatol Arthrosc 2013; 21 (3): 636-40.
  • Thyssen JP, Menne T. Metal allergy--a review on exposures, penetration, genetics, prevalence, and clinical implications. Chem Res Toxicol 2010; 23 (2): 309-18.
  • Thyssen JP, Jakobsen SS, Engkilde K, Johansen JD, Soballe K, Menne T. The association between metal allergy, total hip arthroplasty, and revision. Acta Orthop 2009a; 80 (6): 646-52.
  • Thyssen JP, Johansen JD, Menne T, Nielsen NH, Linneberg A. Nickel allergy in danish women before and after nickel regulation. N Engl J Med 2009b; 360 (21): 2259-60.
  • Thyssen JP, Linneberg A, Menne T, Nielsen NH, Johansen JD. The association between hand eczema and nickel allergy has weakened among young women in the general population following the danish nickel regulation: Results from two cross-sectional studies. Contact Dermatitis 2009c; 61 (6): 342-8.
  • Tyson-Capper AJ, Lawrence H, Holland JP, Deehan DJ, Kirby JA. Metal-on-metal hips: Cobalt can induce an endotoxin-like response. Ann Rheum Dis 2013; 72 (3): 460-1.