In vivo change of elastic property in polyethylene acetabular components

, , &
Pages 140-145 | Received 16 May 2007, Accepted 31 Oct 2007, Published online: 02 Jan 2014

References

  • Schmalzried TP, Clarke IC, McKellop HA. Bearing Surface. In: The Adult Hip. Callaghan JJ, Rosenberg AG, Rubash HE, editors. Philadelphia, New York: Lippincott-Raven; 1998. pp. 247–65.
  • Li S. Polyethylene. In: The Adult Hip. Callaghan JJ, Rosenberg AG, Rubash HE, eds. Philadelphia, New York: Lippincott-Raven; 1998. pp. 105–22.
  • Kurtz SM, Hozack WJ, Purtill JJ, Marcolongo M, Kraay MJ, Goldberg VM, et al. Significance of in vivo degradation for poly-ethylene in total hip arthroplasty. Clin Orthop. 2006;453:47–57.
  • Eyerer P, Ke YC. Property changes of UHMW polyethylene hip cup endoprostheses during implantation. J Biomed Mater Res. 1984;18:1137–51.
  • Kurtz SM, Rimnac CM, Hozack WJ, Turner J, Marcolongo M, Goldberg VM, et al. In vivo degradation of polyethylene liners after gamma sterilization in air. J Bone Joint Surg. 2005; 87–A:815–23.
  • Kurz SM, Bartel DL, Rimnac CM. Postirradiation aging affects stress and strain in polyethylene components. Clin Orthop. 1998;350:209–20.
  • Li S, Burstein AH. Ultra-high molecular weight polyethylene. The material, its use in total joint implants. J Bone, Joint Surg. 1994;76–A:1080–90.
  • Ries MD, Weaver K, Beals N. Safety and efficacy of ethylene oxide sterilized polyethylene in total knee arthroplasty. Clin Orthop. 1996;331:159–63.
  • Wannomae KK, Bhattacharyya S, Freiberg A, Estok D, Harris WH, Muratoglu 0. In vivo oxidation of retrieved cross-linked ultra-high molecular-weight polyethylene acetabular components with residual free radicals. J Arthroplasty. 2006;21:1005–11.
  • Ries MD, Weaver K, Rose RM, Gunther J, Sauer W, Beals N. Fatigue strength of polyethylene after sterilization by gamma irradiation or ethylene oxide. Clin Orthop. 1996;333:87–95.
  • Watanabe E, Suzuki M, Nagata K, Kaneeda T, Harada Y, Utsumi M, et al. Oxidation-induced dynamic changes in morphology reflected on freeze-fractured surface of gamma-irradiated ultra-high molecular weight polyethylene components. J Biomed Mater Res. 2002;62:540–9.
  • Bloebaum RD, Nelson K, Don LD, Hofmann AA, Lyman DJ. Investigation of early surface delamination observed in retrieved heat-pressed tibial inserts. Clin Orthop. 1991;269:120–7.
  • Mckellop H, Shen FW, Lu B, Campbell P, Salovey R. Effect of sterilization method, other modifications on the wear resistance of acetabular cups made of ultra-high molecular weight poly-ethylene. A hip-simulator study. J Bone Joint Surg. 2000;82–A:1708–25.
  • Williams IR, Mayor MB, Collier JP. The impact of sterilization method on wear in knee arthroplasty. Clin Orthop. 1998; 356:170–80.
  • Wroblewski BM. Direction, rate of socket wear in Charnley low-friction arthroplasty. J Bone Joint Surg. 1985;67–B:757–61.
  • Kurtz SM, Rimnac CM, Santner TJ, Bartel DL. Exponential model for the tensile true stress-strain behavior of as-irradiated and oxidatively degraded ultra high molecular weight polyeth-ylene. J Orthop Res. 1996;14:755–61.
  • Kurtz SM, Rimnac CM, Bartel DL. Degradation rate of ultra-high molecular weight polyethylene. J Orthop Res. 1997;15:57–61.
  • Kurtz SM, Hozack W, Marcolongo M, Turner J, Rimnac C, Edidin A. Degradation of mechanical properties of UHMWPE acetabular liners following long-term implantation. J Arthro-plasty. 2003;18(Suppl 1):68–78.
  • Digas G, Thanner J, Nivbrant B, Rohr' S, Strom H, Kärrholm J. Increase in early polyethylene wear after sterilization with eth-ylene oxide: radiostereometric analyses of 201 total hips. Acta Orthop Scand. 2003;74: 531–41.
  • Rohr' SM, Nivbrant B, Strom H, Nilsson KG. Effect of aug-mented cup fixation on stability, wear, and osteolysis: a 5-year follow-up of total hip arthroplasty with RSA. J Arthroplasty. 2004;19:962–71.
  • Sychterz CJ, Orishimo KF, Engh CA. Sterilization and polyeth-ylene wear: clinical studies to support laboratory data. J Bone Joint Surg Am. 2004;86–A(5):1017–22.
  • Oonishi H, Tsuji E, Kim YY. Retrieved total hip prostheses. Part I: the effects of cup thickness, head sizes and fusion defects on wear. J Mater Sci Mater Med. 1998;9:393–401.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.