Towards the quantification of residual milk allergens in caseinate-fined white wines using HPLC coupled with single-stage Orbitrap mass spectrometry

, , , &
Pages 1304-1314 | Received 26 Mar 2011, Accepted 30 May 2011, Published online: 21 Jul 2011
 

Abstract

A method based on LC-ESI-high-resolution (HR)-MS analysis, using a single-stage Orbitrap mass spectrometer, was developed for the quantification of casein allergens potentially present in white wines as a result of fining by caseinate. The method consists of (1) extraction from the matrix by ultrafiltration, (2) digestion with trypsin and (3) detection/quantification of residual caseins, obtained by monitoring the LC-MS response of representative tryptic peptides (peak areas in extracted-ion chromatograms). Method linearity was assessed first on caseinate solutions prepared either in water or in wine matrix (the ultrafiltration residue of a protein-free white wine). Limits of detection (LOD) ranged from 0.1 to 0.3 µg ml−1 (S/N = 3) in water, and between 0.15 and 0.7 µg ml−1 in wine matrix, depending on the selected peptide. Method repeatability and reproducibility, measured as response variability (standard deviation) due to LC-MS analysis alone and to both enzymatic digestion and LC-MS analysis, were assessed on caseinate standard solutions in water and ranged from 5 to 12% and from 8 to 20%, respectively. A higher variability was usually observed for the peptide marker response in the case of matrix-matched samples, the only exception being peptide GPFPIIV from β-casein, the marker also providing the highest sensitivity. The method was finally applied to a casein-free white wine (‘Greco di Tufo’) fined with caseinate at different concentrations, after discarding the precipitate due to casein–wine components aggregation. Minimum detectable added caseinate concentrations (i.e. those corresponding to responses with S/N = 3) were estimated between 39 and 51 µg ml−1, according to the peptide marker chosen. These limits are compatible with caseinate concentrations typically adopted for wine-fining purposes. Moreover, a cross-check with the calibration performed in wine matrix led to an estimation of the concentration of dissolved caseinate to be in the low ng ml−1 range.

Acknowledgements

The authors are grateful to Elisabetta De Angelis and Barbara Introna for their valuable help in performing LC-MS analyses.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.