21
Views
42
CrossRef citations to date
0
Altmetric
ANALYTICAL BIOCHEMISTRY AND CLINICAL ANALYSIS

Enzyme Electrodes For L-Glutamate Using Chemical Redox Mediators and Enzymatic Substrate Amplification

, , , , &
Pages 1273-1288 | Received 15 May 1986, Accepted 20 May 1986, Published online: 06 Dec 2006

Keep up to date with the latest research on this topic with citation updates for this article.

Read on this site (7)

Luis Hernandez, Jose Escalona, Phillipe Verdeguer & NorbertoA. Guzman. (1993) In Vivo Monitoring of Brain Glutamate by Microdialysis Coupled to Capillary Electrophoresis and Laser Induced Fluorescence Detection. Journal of Liquid Chromatography 16:9-10, pages 2149-2160.
Read now
Xiurong Yang, Dorothea Pfeiffer, Gillis Johansson & Frieder Scheller. (1991) Nanomolar Level Amperometric Determination of ATP Through Substrate Recycling in an Enzyme Reactor in a FIA System. Analytical Letters 24:8, pages 1401-1417.
Read now
PaulD. Hale, Hung-Sui Lee, Yoshi Okamoto & TerjeA. Skotheim. (1991) Glutamate Biosensors Based on Electrical Communication Between L-Glutamate Oxidase and a Flexible Redox Polymer. Analytical Letters 24:3, pages 345-356.
Read now
U. Wollenberger, F. Schubert, F. Scheller, B. Danielsson & K. Mosbach. (1987) A Biosensor for ADP with Internal Substrate Amplification. Analytical Letters 20:5, pages 657-668.
Read now
F. Schubert, D. Kirstein, F. Scheller, M. Abraham & L. Boross. (1986) Enzyme Electrode for Fructose, Glucose-6-Phosphate and ATP Determination. Analytical Letters 19:21-22, pages 2155-2167.
Read now

Articles from other publishers (35)

I.S. Kucherenko, O.O. Soldatkin, S.V. Dzyadevych & A.P. Soldatkin. (2020) Electrochemical biosensors based on multienzyme systems: Main groups, advantages and limitations – A review. Analytica Chimica Acta 1111, pages 114-131.
Crossref
Yong Duk Han, Yo Han Jang & Hyun C. Yoon. 2014. Biosensors Based on Aptamers and Enzymes. Biosensors Based on Aptamers and Enzymes 221 251 .
Malika Ammam & Jan Fransaer. (2010) Highly sensitive and selective glutamate microbiosensor based on cast polyurethane/AC-electrophoresis deposited multiwalled carbon nanotubes and then glutamate oxidase/electrosynthesized polypyrrole/Pt electrode. Biosensors and Bioelectronics 25:7, pages 1597-1602.
Crossref
Fumio MIZUTANI, Dai KATO, Ryoji KURITA, Yasuhiro MIE, Yukari SATO & Osamu NIWA. (2008) Highly-sensitive Biosensors with Chemically-amplified Responses. Electrochemistry 76:8, pages 515-521.
Crossref
Wanida Khampha, Vithaya Meevootisom & Suthep Wiyakrutta. (2004) Spectrophotometric enzymatic cycling method using l-glutamate dehydrogenase and d-phenylglycine aminotransferase for determination of l-glutamate in foods. Analytica Chimica Acta 520:1-2, pages 133-139.
Crossref
Maite Sanz Alaejos & Francisco Jorge García Montelongo. (2004) Application of Amperometric Biosensors to the Determination of Vitamins and α-Amino Acids. Chemical Reviews 104:7, pages 3239-3266.
Crossref
Frieder Scheller, Ulla Wollenberger, Christian G, Axel Warsinke, Alexander Makower & Frank Bier. 2002. Biomolecular Sensors. Biomolecular Sensors.
Osamu Niwa, Tsutomu Horiuchi, Ryoji Kurita, Hisao Tabei & Keiichi Torimitsu. (1998) Microfabricated On-Line Sensor for Continuous Monitoring of l-Glutamate. Analytical Sciences 14:5, pages 947-953.
Crossref
Sonia Tucci, Pedro Rada, M.Jacqueline Sepúlveda & Luis Hernandez. (1997) Glutamate measured by 6-s resolution brain microdialysis: capillary electrophoretic and laser-induced fluorescence detection application. Journal of Chromatography B: Biomedical Sciences and Applications 694:2, pages 343-349.
Crossref
U. Wollenberger, F. Lisdat & F. W. Scheller. 1996. Frontiers in Biosensorics II. Frontiers in Biosensorics II 45 69 .
Frank F. Bier, Eva Ehrentreich-Förster, Frieder W. Scheller, Alexander Makower, Arkadi Eremenko, Ulla Wollenberger, Christian G. Bauer, Dorothea Pfeiffer & Norbeit Michael. (1996) Ultrasensitive biosensors. Sensors and Actuators B: Chemical 33:1-3, pages 5-12.
Crossref
Frank F Bier, Eva Ehrentreich-Förster, Alexander Makower & Frieder W Scheller. (1996) An enzymatic amplification cycle for high sensitive immunoassay. Analytica Chimica Acta 328:1, pages 27-32.
Crossref
Ulla Wollenberger, Florian Schubert, Dorothea Pfeiffer & Frieder W. Scheller. 1996. Biochemical Technology. Biochemical Technology 381 390 .
Hanns‐Ludwig Schmidt, Wolfgang Schuhmann, Tu München, Friedrich W. Scheller & Florian Schubert. 1995. Sensors Set. Sensors Set 717 817 .
Shoichiro Yoshida, Hiroshi Kanno & Tadashi Watanabe. (1995) Glutamate Sensors Carrying Glutamate Oxidase/Peroxidase Bienzyme System on Tin Oxide Electrode. Analytical Sciences 11:2, pages 251-256.
Crossref
A.L. Ghindilis, A. Makower, C.G. Bauer, F.F. Bier & F.W. Scheller. (1995) Determination of p-aminophenol and catecholamines at picomolar concentrations based on recycling enzyme amplification. Analytica Chimica Acta 304:1, pages 25-31.
Crossref
F.W. Scheller, A. Makower, A.L. Ghindilis, F.F. Bier, E. Forster, U. Wollenberger, C. Bauer, D. Pfeiffer, J. Szeponik & W. Oelzner. (1995) Ultrasensitive Biosensors. Ultrasensitive Biosensors.
Jinlan Xia, Yexiang Liu & J M Levert. (1994) Bisensors for amino acids. Journal of Central South University of Technology 1:1, pages 51-58.
Crossref
Francesco Botrè, Claudio Botrè, Giampiero Lorenti, Franco Mazzei, Fernando Porcelli & Giancarlo Scibona. (1993) Determination of l-glutamate and l-glutamine in pharmaceutical formulations by amperometric l-glutamate oxidase based enzyme sensors. Journal of Pharmaceutical and Biomedical Analysis 11:8, pages 679-686.
Crossref
Ulla Wollenberger, Florian Schubert, Dorothea Pfeiffer & Frieder W. Scheller. (1993) Enhancing biosensor performance using multienzyme systems. Trends in Biotechnology 11:6, pages 255-262.
Crossref
John H. T. Luong, A. -L. Nguyen & George G. Guilbault. 1993. Measurement and Control. Measurement and Control 85 115 .
Claudio Botrè, Francesco Botrè, Marco Galli, Giampiero Lorenti, Franco Mazzei & Fernando Porcelli. (1992) Determination of glutamic acid decarboxylase activity and inhibition by an H2O2-sensing glutamic acid oxidase biosensor. Analytical Biochemistry 201:2, pages 227-232.
Crossref
J.‐M. Kauffmann & G. G. Guilbault. 1992. Methods of Biochemical Analysis. Methods of Biochemical Analysis 63 113 .
. 1992. Biosensors. Biosensors 329 351 .
Hanns‐Ludwig Schmidt, Wolfgang Schuhmann, Tu München, Friedrich W. Scheller & Florian Schubert. 1991. Sensors. Sensors 717 817 .
Bernd A.A. Dremel, Rolf D. Schmid & Otto S. Wolfbeis. (1991) Comparison of two fibre-optic l-glutamate biosensors based on the detection of oxygen or carbon dioxide, and their application in combination with flow-injection analysis to the determination of glutamate. Analytica Chimica Acta 248:2, pages 351-359.
Crossref
Xiurong Yang, Gillis Johansson, Dorothea Pfeiffer & Frieder Scheller. (2005) Enzyme electrodes for ADP/ATP with enhanced sensitivity due to chemical amplification and intermediate accumulation. Electroanalysis 3:7, pages 659-663.
Crossref
Florian Schubert, Jürgen Lutter & Frieder Scheller. (1991) Augmentation of enzyme electrode sensitivity using biocatalytic preconcentration. Analytica Chimica Acta 243, pages 17-21.
Crossref
Florian Schubert, Selwayan Saini & Anthony P.F. Turner. (1991) Mediated amperometric enzyme electrode incorporating peroxidase for the determination of hydrogen peroxide in organic solvents. Analytica Chimica Acta 245, pages 133-138.
Crossref
Florian Schubert, Frieder Scheller & Nikolina G. Krasteva. (2005) Lactate‐dehydrogenase‐based biosensors for glyoxylate and NADH determination: A novel principle of analyte recyling. Electroanalysis 2:5, pages 347-351.
Crossref
Ulla Wollenberger, Frieder W. Scheller, Anette Böhmer, Margrit Passarge & Hans-Georg Müller. (1989) A specific enzyme electrode for l-glutamate-development and application. Biosensors 4:6, pages 381-391.
Crossref
Frieder Scheller & Florian SchubertFrieder Scheller & Florian Schubert. 1989. Biosensoren. Biosensoren 320 346 .
Frieder W. Scheller, Plorian Schubert, Dietmar Weigelt, Peter Mohr & Ulla Wollenberger. (2011) Molecular recognition and signal processing in biosensors. Makromolekulare Chemie. Macromolecular Symposia 17:1, pages 429-439.
Crossref
FRIEDER W. SCHELLER, FLORIAN SCHUBERT, DOROTHEA PFEIFFER & REINHARD RENNEBERG. (2006) Intelligent Biosensors. Annals of the New York Academy of Sciences 501:1, pages 240-248.
Crossref
Thomas Schulmeister. (1987) Mathematical treatment of concentration profiles and anodic current of amperometric enzyme electrodes with chemically-amplified response. Analytica Chimica Acta 201, pages 305-310.
Crossref

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.