247
Views
36
CrossRef citations to date
0
Altmetric
MILITARY MEDICINE

Use of Ultrasonography to Avoid an Unnecessary Procedure in the Prehospital Combat Environment: A Case Report

, , MD, MCR & , MD
Pages 502-506 | Received 19 Jan 2006, Accepted 19 Jun 2006, Published online: 02 Jul 2009

Keep up to date with the latest research on this topic with citation updates for this article.

Read on this site (2)

Nicholas von Foerster, Marek A. Radomski & Christian Martin-Gill. (2022) Prehospital Ultrasound: A Narrative Review. Prehospital Emergency Care 0:0, pages 1-13.
Read now
Christopher R. McNeil, John McManus & Sumeru Mehta. (2009) The Accuracy of Portable Ultrasonography to Diagnose Fractures in an Austere Environment. Prehospital Emergency Care 13:1, pages 50-52.
Read now

Articles from other publishers (34)

Giti Nadim, Christian B. Laursen, Pia I. Pietersen, Daniel Wittrock, Michael K. Sørensen, Lars B. Nielsen, Claus-Henrik Rasmussen, Helle Marie Christensen, Simon Helmerik, Gitte Jørgensen, Ingrid L. Titlestad, Annmarie T. Lassen & Søren Mikkelsen. (2021) Prehospital emergency medical technicians can perform ultrasonography and blood analysis in prehospital evaluation of patients with chronic obstructive pulmonary disease: a feasibility study. BMC Health Services Research 21:1.
Crossref
E. Brooke Lerner, David C. Cone & Donald M. Yealy. 2021. Emergency Medical Services. Emergency Medical Services 457 466 .
Andrew Cathers & Nikolai Schnittke. 2021. Manual of Austere and Prehospital Ultrasound. Manual of Austere and Prehospital Ultrasound 93 113 .
Patrick G A Duncan & J Mackey. (2020) Point-of-care ultrasound at Role 1: is it time for a rethink?. BMJ Military Health 166:6, pages 406-410.
Crossref
Joseph Betcher, Torben K. Becker, Peter Stoyanoff, Jim Cranford & Nik Theyyunni. (2018) Military trainees can accurately measure optic nerve sheath diameter after a brief training session. Military Medical Research 5:1.
Crossref
Muneichi Shibata, Hiroshi Chiba, Kazuhiro Sasaki, Shinsaku Ueda, Osamu Yamamura & Kazuhiko Hanzawa. (2017) The utility of on-site ultrasound screening in population at high risk for deep venous thrombosis in temporary housing after the great East Japan Earthquake. Journal of Clinical Ultrasound 45:9, pages 566-574.
Crossref
Tim Harris, Adam Bystrzycki & Stefan M. Mazur. 2017. Emergency Point‐of‐Care Ultrasound. Emergency Point‐of‐Care Ultrasound 423 439 .
Laleh Gharahbaghian, Kenton L. Anderson, Viveta Lobo, Rwo-Wen Huang, Cori McClure Poffenberger & Phi D. Nguyen. (2017) Point-of-Care Ultrasound in Austere Environments. Emergency Medicine Clinics of North America 35:2, pages 409-441.
Crossref
E. Falzone, P. Pasquier, C. Hoffmann, O. Barbier, M. Boutonnet, A. Salvadori, A. Jarrassier, J. Renner, B. Malgras & S. Mérat. (2017) Triage in military settings. Anaesthesia Critical Care & Pain Medicine 36:1, pages 43-51.
Crossref
Frances Corcoran, Adam Bystrzycki, Syed Masud, Stefan M Mazur, David Wise & Tim Harris. (2015) Ultrasound in pre-hospital trauma care. Trauma 18:2, pages 101-110.
Crossref
S. M. Wydo, M. J. Seamon, S. W. Melanson, P. Thomas, D. P. Bahner & S. P. Stawicki. (2015) Portable ultrasound in disaster triage: a focused review. European Journal of Trauma and Emergency Surgery 42:2, pages 151-159.
Crossref
Jacob A. Quick, Rindi M. Uhlich, Salman Ahmad, Stephen L. Barnes & Jeffrey P. Coughenour. (2015) In-flight ultrasound identification of pneumothorax. Emergency Radiology 23:1, pages 3-7.
Crossref
Olga Maurin, S De Regloix, H Lefort, G Delort, L Domanski, J-P Tourtier & B Palmier. (2014) French military general practitioner: ultrasound practice. Journal of the Royal Army Medical Corps 160:3, pages 213-216.
Crossref
Jen-Tang Sun, Chun-Yen Huang, Yi-Shin Huang, Shyh-Shyong Sim, Kah-Meng Chong, Hsiu-Po Wang & Wan-Ching Lien. (2014) Prehospital Ultrasound. Journal of Medical Ultrasound 22:2, pages 71-77.
Crossref
Paul McBethInnes CrawfordCorina TirutaZhengwen XiaoGeorge Qiaohao ZhuMichael ShusterLes SewellNova PanebiancoDavid LautnerSavvas NicolaouChad G. BallMichael BlaivasChristopher J. DenteAmy D. WyrzykowskiAndrew W. Kirkpatrick. (2013) Help Is in Your Pocket: The Potential Accuracy of Smartphone- and Laptop-Based Remotely Guided Resuscitative Telesonography. Telemedicine and e-Health 19:12, pages 924-930.
Crossref
Muneichi Shibata & Tomoyuki Yambe. (2013) The use of portable ultrasound machine to assess a shelter's environment using venous thromboembolism screening. The use of portable ultrasound machine to assess a shelter's environment using venous thromboembolism screening.
Linping Pian, Lawrence M. Gillman, Paul B. McBeth, Zhengwen Xiao, Chad G. Ball, Michael Blaivas, Douglas R. Hamilton & Andrew W. Kirkpatrick. (2013) Potential Use of Remote Telesonography as a Transformational Technology in Underresourced and/or Remote Settings. Emergency Medicine International 2013, pages 1-9.
Crossref
Matthew Lyon, Perry Walton, Valori Bhalla & Stephen A. Shiver. (2012) Ultrasound detection of the sliding lung sign by prehospital critical care providers. The American Journal of Emergency Medicine 30:3, pages 485-488.
Crossref
Lori Whelan, William Justice, Jeffrey M. Goodloe, Jeff D. Dixon & Stephen H. Thomas. (2012) Trauma Ultrasound in Civilian Tactical Medicine. Emergency Medicine International 2012, pages 1-6.
Crossref
Andrew Beckett, Erin Savage, Dylan Pannell, Sanjay Acharya, Andy Kirkpatrick & Homer C. Tien. (2011) Needle Decompression for Tension Pneumothorax in Tactical Combat Casualty Care: Do Catheters Placed in the Midaxillary Line Kink More Often Than Those in the Midclavicular Line?. Journal of Trauma: Injury, Infection & Critical Care 71:5, pages S408-S412.
Crossref
Bret P. Nelson, Edward R. Melnick & James Li. (2011) Portable Ultrasound for Remote Environments, Part II: Current Indications. The Journal of Emergency Medicine 40:3, pages 313-321.
Crossref
Bret P. Nelson, Edward R. Melnick & James Li. (2011) Portable Ultrasound for Remote Environments, Part I: Feasibility of Field Deployment. The Journal of Emergency Medicine 40:2, pages 190-197.
Crossref
Phillip D. Levy, Tracey Wielinski & Alan Greszler. (2011) Micropower Impulse Radar: A Novel Technology for Rapid, Real-Time Detection of Pneumothorax. Emergency Medicine International 2011, pages 1-5.
Crossref
Hans Xaver Hoyer, Stefan Vogl, Uwe Schiemann, Alexander Haug, Erwin Stolpe & Thomas Michalski. (2010) Prehospital ultrasound in emergency medicine: incidence, feasibility, indications and diagnoses. European Journal of Emergency Medicine 17:5, pages 254-259.
Crossref
Henrik Jørgensen, Carsten H. Jensen & Jesper Dirks. (2010) Does prehospital ultrasound improve treatment of the trauma patient? A systematic review. European Journal of Emergency Medicine 17:5, pages 249-253.
Crossref
Justin J. Madill. (2010) In-Flight Thoracic Ultrasound Detection of Pneumothorax in Combat. The Journal of Emergency Medicine 39:2, pages 194-197.
Crossref
William Heegaard, David Hildebrandt, David Spear, Kevin Chason, Bret Nelson & Jeffrey Ho. (2010) Prehospital Ultrasound by Paramedics: Results of Field Trial. Academic Emergency Medicine 17:6, pages 624-630.
Crossref
Stanislaw Peter Stawicki. (2010) Portable ultrasonography in mass casualty incidents: The CAVEAT examination. World Journal of Orthopedics 1:1, pages 10.
Crossref
Andrew W. Kirkpatrick. (2010) Trauma Association of Canada 2009 Presidential Address: Trauma Ultrasound in Canada—Have We Lost a Generation?. Journal of Trauma: Injury, Infection & Critical Care 68:1, pages 2-8.
Crossref
Vivek S. Tayal & Casey M. Glass. 2010. Rosen's Emergency Medicine – Concepts and Clinical Practice. Rosen's Emergency Medicine – Concepts and Clinical Practice 2531 2539 .
Lawrence M Gillman, Chad G Ball, Nova Panebianco, Azzam Al-Kadi & Andrew W Kirkpatrick. (2009) Clinician performed resuscitative ultrasonography for the initial evaluation and resuscitation of trauma. Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine 17:1.
Crossref
Azzam S. Al-Kadi, Lawrence M. Gillman, Chad G. Ball, Nova L. Panebianco & Andrew W. Kirkpatrick. (2009) Resuscitative Long-Bone Sonography for the Clinician: Usefulness and Pitfalls of Focused Clinical Ultrasound to Detect Long-Bone Fractures During Trauma Resuscitation. European Journal of Trauma and Emergency Surgery 35:4, pages 357-363.
Crossref
. (2009) Emergency Ultrasound Guidelines. Annals of Emergency Medicine 53:4, pages 550-570.
Crossref
Maarten J.J. Hoejenbos, John McManus & Timothy Hodgetts. (2012) Is There One Optimal Medical Treatment and Evacuation Chain for All Situations: “Scoop-and-Run” or “Stay-and-Play”. Prehospital and Disaster Medicine 23:S2, pages s74-s78.
Crossref

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.