21
Views
61
CrossRef citations to date
0
Altmetric
Original Article

Design of a clinical deep-body hyperthermia system based on the ‘coaxial TEM’ applicator

&
Pages 413-421 | Received 06 Mar 1987, Published online: 09 Jul 2009

Keep up to date with the latest research on this topic with citation updates for this article.

Read on this site (29)

H. Petra Kok, Martijn De Greef, Niek Van Wieringen, Davi Correia, Maarten C.C.M. Hulshof, Paul J. Zum Vörde Sive Vörding, Jan Sijbrands, Arjan Bel & Johannes Crezee. (2010) Comparison of two different 70 MHz applicators for large extremity lesions: Simulation and application. International Journal of Hyperthermia 26:4, pages 376-388.
Read now
P. Wust, M. Seebass, J. Nadobny, P. Deuflhard, G. Mönich & R. Felix. (2009) Simulation studies promote technological development of radiofrequency phased array hyperthermia. International Journal of Hyperthermia 25:7, pages 517-528.
Read now
A. A. C. De Leeuw, M. Van Vulpen, J. B. Van De Kamer, C. C. Wárlám-Rodenhuis & J. J. W. Lagendijk. (2003) Increasing the systemic temperature during regional hyperthermia: effect of a cooling strategy on tumour temperatures and side-effects. International Journal of Hyperthermia 19:6, pages 655-663.
Read now
H. Kroeze, M. Van Vulpen, A. A. C. De Leeuw, J. B. Van De Kamer & Jan J. W. Lagendijk. (2003) Improvement of absorbing structures used in regional hyperthermia. International Journal of Hyperthermia 19:6, pages 598-616.
Read now
J. B. Van De Kamer, A. A. C. De Leeuw, S. N. Hornsleth, H. Kroeze, A. N. T. J. Kotte, J. J. W. Lagendijk. (2001) Development of a regional hyperthermia treatment planning system. International Journal of Hyperthermia 17:3, pages 207-220.
Read now
H. Kroeze, M. Van Vulpen, A. A. C. De Leeuw, J. B. Van De Kamer, J. J. W. Lagendijk. (2001) The use of absorbing structures during regional hyperthermia treatment. International Journal of Hyperthermia 17:3, pages 240-257.
Read now
P. Wust, H. Fähling, T. Helzel, M. Kniephoff, W. Wlodarczyk, G. Mönich & R. Felix. (1998) Design and test of a new multi-amplifier system with phase and amplitude control. International Journal of Hyperthermia 14:5, pages 459-477.
Read now
J. J. W. Lagendijk, G. C. Van Rhoon, S. N. Hornsleth, P. Wust, A. C. C. De Leeuw, C. J. Schneider, J. D. P. Van Ddk, J. Van Der Zee, R. Van Heek-Romanowski, S. A. Rahman & C. Gromoll. (1998) Esho Quality Assurance Guidelines for Regional Hyperthermia. International Journal of Hyperthermia 14:2, pages 125-133.
Read now
J Behari & G P Srivastava. (1997) Electromagnetic Field Interaction with Biological Systems and Microwave Hyperthermia. IETE Technical Review 14:3, pages 141-147.
Read now
J. Van Der Zee, H. D. Wiersema, M. P. Broekmeyer-Reurink & G. C. Van Rhoon. (1997) Intraspinal temperatures during regional deep hyperthermia induced by electromagnetic radiation in the Macaco, mulatta. International Journal of Hyperthermia 13:2, pages 149-155.
Read now
P. Wust, M. Seebass, J. Nadobny, P. Deuflhard, G. Mönich & R. Felix. (1996) Simulation studies promote technological development of radiofrequency phased array hyperthermia. International Journal of Hyperthermia 12:4, pages 477-494.
Read now
G. H. Nussbaum, J. Sidi, M. Dipalma, R. Adam, M. D. Ghnassia, P. Navarro, J. W. Hand, M. Nagi, M. Rotarsky, N. P. Plaza, M. Ionescu-Goga, P. Morel, P. Alhomme, J. M. Vannetzel, H. Bismuth & C. Jasmin. (1996) Production and manipulation of elevated temperatures in pig abdomen with a three-electrode capacitive heating device. International Journal of Hyperthermia 12:3, pages 421-430.
Read now
P. Wust, H. Fähling, R. Felix, S. Rahman, R. D. Issels, H. Feldmanns, G. Van Rhoon & J. Van Der Zee. (1995) Quality control of the SIGMA applicator using a lamp phantom: a four-centre comparison. International Journal of Hyperthermia 11:6, pages 755-768.
Read now
C. A. Van Es, H. K. Wyrdeman, A. A. C. De Leeuw, J. Mooibroek, J. J. W. Lagendijk & J. J. Battermann. (1995) Regional hyperthermia of pelvic tumours using the Utrecht ‘Coaxial TEM’ system: a feasibility study. International Journal of Hyperthermia 11:2, pages 173-186.
Read now
P. Wust, H. Stahl, J. Löffel, M. Seebass, H. Riess & R. Felix. (1995) Clinical, physiological and anatomical determinants for radiofrequency hyperthermia. International Journal of Hyperthermia 11:2, pages 151-167.
Read now
Povl Raskmark, Sten N. Hornsleth, Lisbeth N. Salling, Jacob C. Lindegaard & Jens Overgaard. (1994) Deep Heating Using a Movable Applicator Phased Array Hyperthermia System: A preclinical feasibility study. Acta Oncologica 33:4, pages 451-455.
Read now
C. J. Schneider, J. D. P. Van Dijk, A. A. C. De Leeuw, P. Wust & W. Baumhoer. (1994) Quality assurance in various radiative hyperthermia systems applying a phantom with LED matrix. International Journal of Hyperthermia 10:5, pages 733-747.
Read now
X. Jia, K. D. Paulsen, D. N. Buechler, F. A. Gibbs & P. M. Meaney. (1994) Finite element simulation of Sigma 60 heating in the Utah phantom: computed and measured data compared. International Journal of Hyperthermia 10:6, pages 755-774.
Read now
P. Wust, H. Fähling, A. Jordan, J. Nadobny, M. Seebass & R. Felix. (1994) Development and testing of SAR-visualizing phantoms for quality control in RF hyperthermia. International Journal of Hyperthermia 10:1, pages 127-142.
Read now
A. A. C. De Leeuw, J. Crezee & J. J. W. Lagendijk. (1993) Temperature and SAR measurements in deep-body hyperthermia with thermocouple thermometry. International Journal of Hyperthermia 9:5, pages 685-697.
Read now
C. J. Schneider, A. A. C. De Leeuw & J. D. P. Van Dijk. (1992) Quantitative determination of SAR profiles from photographs of the light-emitting diode matrix. International Journal of Hyperthermia 8:5, pages 609-619.
Read now
G. C. Van Rhoon, J. van der Zee, M. P. Broekmeyer-Reurink, A. G. Visser & H. S. Reinhold. (1992) Radiofrequency capacitive heating of deep-seated tumours using pre-cooling of the subcutaneous tissues: Results on thermometry in Dutch patients. International Journal of Hyperthermia 8:6, pages 843-854.
Read now
A. A. C. de Leeuw, J. Mooibroek & J. J. W. Lagendijk. (1991) Specific absorption rate steering by patient positioning in the ‘Coaxial TEM’ system: Phantom investigation. International Journal of Hyperthermia 7:4, pages 605-611.
Read now
A. A. C. De Leeuw, J. J. W. Lagendijk & P. M. Van Den Berg. (1990) SAR distribution of the‘coaxial TEM’system with variable aperture width: Measurements and model computations. International Journal of Hyperthermia 6:2, pages 445-451.
Read now
R. Valdagni. (1990) International Consensus Meeting on Hyperthermia: Final Report Castel Ivano, Trento, Italy 2–6 May 1989. International Journal of Hyperthermia 6:5, pages 837-877.
Read now
D. Anhalt, K. Hynynen, D. Deyoung, D. Shimm, M. Kundrat & T. Cetas. (1990) The CDRH Helix: An in vivo evaluation. International Journal of Hyperthermia 6:1, pages 241-252.
Read now
William H. Harrison & F. Kristian Storm. (1989) Loosely coupled coaxial TEM applicators for deep-heating. International Journal of Hyperthermia 5:3, pages 297-306.
Read now
A. P. M. Zwamborn & P. M. Van Den Berg. (1989) A computational model for heat generation in a radially layered tissue inside a ‘coaxial TEM’ applicator. International Journal of Hyperthermia 5:2, pages 211-223.
Read now

Articles from other publishers (32)

Riccardo Ferrero, Ioannis Androulakis, Luca Martino, Robin Nadar, Gerard C. van Rhoon & Alessandra Manzin. (2022) Design and Characterization of an RF Applicator for In Vitro Tests of Electromagnetic Hyperthermia. Sensors 22:10, pages 3610.
Crossref
Johannes Crezee, Geertjan Van Tienhoven, Merel W. Kolff, Jan Sijbrands, Gerard Van Stam, Sabine Oldenborg, Elisabeth D. Geijsen, Maarten C.C.M. Hulshof & Henny P. Kok. (2017) Development of a 70 MHz unit for hyperthermia treatment of deep-seated breast tumors. International Journal of Microwave and Wireless Technologies 9:6, pages 1317-1324.
Crossref
J Crezee, G van Tienhoven, M W Kolff, J Sijbrands, G van Stam, S Oldenborg, E D Geysen, M C C M Hulshof & H P Kok. (2016) Development of a 70 MHz unit for hyperthermia treatment of deep seated breast tumors. Development of a 70 MHz unit for hyperthermia treatment of deep seated breast tumors.
Anna Andreychenko, Hugo Kroeze, Dennis W. J. Klomp, Jan J. W. Lagendijk, Peter R. Luijten & Cornelis A. T. van den Berg. (2013) Coaxial waveguide for travelling wave MRI at ultrahigh fields. Magnetic Resonance in Medicine 70:3, pages 875-884.
Crossref
S. E. Combs. 2013. Strahlentherapie. Strahlentherapie 225 248 .
M de Greef, H P Kok, D Correia, P-P Borsboom, A Bel & J Crezee. (2011) Uncertainty in hyperthermia treatment planning: the need for robust system design. Physics in Medicine and Biology 56:11, pages 3233-3250.
Crossref
H P Kok, M de Greef, J Wiersma, A Bel & J Crezee. (2010) The impact of the waveguide aperture size of the 3D 70 MHz AMC-8 locoregional hyperthermia system on tumour coverage. Physics in Medicine and Biology 55:17, pages 4899-4916.
Crossref
P. Wust, B. Rau & P. M. Schlag. 2010. Praxis der Viszeralchirurgie Onkologische Chirurgie. Praxis der Viszeralchirurgie Onkologische Chirurgie 319 332 .
H. P. Kok, M. de Greef, A. Bel & J. Crezee. (2009) Acceleration of high resolution temperature based optimization for hyperthermia treatment planning using element grouping. Medical Physics 36:8, pages 3795-3805.
Crossref
Cornelis A T Van den Berg, Jeroen B Van de Kamer, Astrid A C De Leeuw, Cécile R L P N Jeukens, Bas W Raaymakers, Marco van Vulpen & Jan J W Lagendijk. (2006) Towards patient specific thermal modelling of the prostate. Physics in Medicine and Biology 51:4, pages 809-825.
Crossref
S. E. Combs. 2006. Strahlentherapie. Strahlentherapie 177 196 .
P. Wust, B. Rau & P. M. Schlag. 2006. Praxis der Viszeralchirurgie. Praxis der Viszeralchirurgie 247 258 .
H P Kok, P M A Van Haaren, J B Van de Kamer, J Wiersma, J D P Van Dijk & J Crezee. (2005) High-resolution temperature-based optimization for hyperthermia treatment planning. Physics in Medicine and Biology 50:13, pages 3127-3141.
Crossref
Jacek Nadobny, Waldemar Wlodarczyk, Lothar Westhoff, Johanna Gellermann, Beate Rau, Gerhard Mönich & Peter Wust. (2003) Development and evaluation of a three-dimensional hyperthermia applicator with water-coated antennas (WACOA). Medical Physics 30:8, pages 2052-2064.
Crossref
W. Wlodarczyk, P. Wust, M. Seebass, J. Gellermann & J. Nadobny. (2002) RF hyperthermia: modeling and clinical systems. RF hyperthermia: modeling and clinical systems.
H Kroeze, J B Van de Kamer, A A C De Leeuw & J J W Lagendijk. (2001) Regional hyperthermia applicator design using FDTD modelling. Physics in Medicine and Biology 46:7, pages 1919-1935.
Crossref
J B Van de Kamer, H Kroeze, A A C De Leeuw & J J W Lagendijk. (2001) Quasistatic zooming of FDTD E -field computations: the impact of down-scaling techniques . Physics in Medicine and Biology 46:5, pages 1539-1551.
Crossref
J B Van de Kamer, A A C De Leeuw, H Kroeze & J J W Lagendijk. (2001) Quasistatic zooming for regional hyperthermia treatment planning. Physics in Medicine and Biology 46:4, pages 1017-1030.
Crossref
J B Van de Kamer, J J W Lagendijk, A A C De Leeuw & H Kroeze. (2001) High-resolution SAR modelling for regional hyperthermia: testing quasistatic zooming at 10 MHz. Physics in Medicine and Biology 46:1, pages 183-196.
Crossref
P. Wust, B. Rau & P. Schlag. 2001. Praxis der Viszeralchirurgie. Praxis der Viszeralchirurgie 227 239 .
P. Wust, J. Gellermann, B. Rau, J. Löffel, A. Speidel, H. Stahl, H. Riess, T. J. Vogl, R. Felix & P. M. Schlag. 1996. New Perspectives in Molecular and Clinical Management of Gastrointestinal Tumors. New Perspectives in Molecular and Clinical Management of Gastrointestinal Tumors 281 309 .
H. J. Feldmann & M. Molls. 1996. Strahlentherapie. Strahlentherapie 181 188 .
M. Heinrich Seegenschmiedt, Peter Fessenden & Clare C. VernonM. Heinrich Seegenschmiedt & Horst J. Feldmann. 1996. Thermoradiotherapy and Thermochemotherapy. Thermoradiotherapy and Thermochemotherapy 3 23 .
F. Bardati, A. Borrani, A. Gerardino & G.A. Lovisolo. (1995) SAR optimization in a phased array radiofrequency hyperthermia system. IEEE Transactions on Biomedical Engineering 42:12, pages 1201-1207.
Crossref
C. J. Schneider, R. Olmi & J. D. P. van Dijk. 1995. Thermoradiotherapy and Thermochemotherapy. Thermoradiotherapy and Thermochemotherapy 381 397 .
P. Wust, M. Seebass, J. Nadobny & R. Felix. 1995. Thermoradiotherapy and Thermochemotherapy. Thermoradiotherapy and Thermochemotherapy 219 251 .
G. C. van Rhoon, P. Raskmark, S. N. Hornseth & P. M. van den Berg. (1994) Radio-frequency ring applicator: energy distributions measured in the CDRH phantom. Medical and Biological Engineering and Computing 32:6, pages 643-648.
Crossref
C.H. Durney. (1992) Antennas and other electromagnetic applicators in biology and medicine. Proceedings of the IEEE 80:1, pages 194-199.
Crossref
J. W. Hand. 1990. Methods of External Hyperthermic Heating. Methods of External Hyperthermic Heating 1 59 .
R. B. Roemer. 1990. Thermal Dosimetry and Treatment Planning. Thermal Dosimetry and Treatment Planning 119 214 .
G. C. van Rhoon, G. van den Bos & J. van der Zee. 1990. Consensus on Hyperthermia for the 1990s. Consensus on Hyperthermia for the 1990s 57 77 .
Chung-Kwang Chou & Kenneth H. Luk. 1990. Emerging Electromagnetic Medicine. Emerging Electromagnetic Medicine 205 223 .

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.