1,155
Views
20
CrossRef citations to date
0
Altmetric
Research Article

A randomized study on migration of the Spectron EF and the Charnley flanged 40 cemented femoral components using radiostereometric analysis at 2 years

, , , , , , , , & show all
Pages 538-544 | Received 11 Oct 2010, Accepted 24 Apr 2011, Published online: 24 Nov 2011

Keep up to date with the latest research on this topic with citation updates for this article.

Read on this site (5)

Mika Junnila, Inari Laaksonen, Antti Eskelinen, Pekka Pulkkinen, Leif Ivar Havelin, Ove Furnes, Anne Marie Fenstad, Alma B Pedersen, Søren Overgaard, Johan Kärrholm, Göran Garellick, Henrik Malchau & Keijo T Mäkelä. (2016) Implant survival of the most common cemented total hip devices from the Nordic Arthroplasty Register Association database. Acta Orthopaedica 87:6, pages 546-553.
Read now
Rami Madanat, Tatu J Mäkinen, Hannu T Aro, Charles Bragdon & Henrik Malchau. (2014) Adherence of hip and knee arthroplasty studies to RSA standardization guidelines. Acta Orthopaedica 85:5, pages 447-455.
Read now
Martin Clauss, Silke Gersbach, Andre Butscher & Thomas Ilchmann. (2013) Risk factors for aseptic loosening of Müller-type straight stems. Acta Orthopaedica 84:4, pages 353-359.
Read now
Einar Lindalen, Jon Dahl, Lars Nordsletten, Finnur Snorrason, Øystein Høvik & Stephan Röhrl. (2012) Reverse hybrid and cemented hip replacement compared using radiostereometry and dual-energy X-ray absorptiometry. Acta Orthopaedica 83:6, pages 592-598.
Read now

Articles from other publishers (15)

Paul Johan Høl, Geir Hallan, Ove Furnes, Anne Marie Fenstad, Kari Indrekvam & Thomas Kadar. (2022) Similarly low blood metal ion levels at 10‐years follow‐up of total hip arthroplasties with Oxinium, CoCrMo, and stainless steel femoral heads. Data from a randomized clinical trial . Journal of Biomedical Materials Research Part B: Applied Biomaterials 111:4, pages 821-828.
Crossref
Cécile Batailler, Jobe Shatrov, Axel Schmidt, Elvire Servien, Jean Marc Puch & Sébastien Lustig. (2021) Similar stress repartition for a standard uncemented collared femoral stem versus a shortened collared femoral stem. SICOT-J 7, pages 58.
Crossref
Bernhard Flatøy, Jon Dahl, Stephan Maximilian Röhrl & Lars Nordsletten. (2019) Does radiopaque cement conceal periprosthetic bone loss around femoral stems?. HIP International 30:6, pages 731-738.
Crossref
T. B. KristensenE. DybvikO. FurnesL. B. EngesæterJ-E. Gjertsen. (2018) More reoperations for periprosthetic fracture after cemented hemiarthroplasty with polished taper-slip stems than after anatomical and straight stems in the treatment of hip fractures. The Bone & Joint Journal 100-B:12, pages 1565-1571.
Crossref
Matthew G Teeter, Richard W McCalden, Xunhua Yuan, Steven J MacDonald & Douglas D Naudie. (2018) Predictive accuracy of RSA migration thresholds for cemented total hip arthroplasty stem designs. HIP International 28:4, pages 363-368.
Crossref
Nicolas Bonin, Jean-Emmanuel Gedouin, Vincent Pibarot, Jacques Bejui-Hughues, Hugo Bothorel, Mo Saffarini & Cécile Batailler. (2017) Proximal femoral anatomy and collared stems in hip arthroplasty: is a single collar size sufficient?. Journal of Experimental Orthopaedics 4:1.
Crossref
Per-Erik Johanson, Martin Antonsson, Bita Shareghi & Johan Kärrholm. (2016) Early Subsidence Predicts Failure of a Cemented Femoral Stem With Minor Design Changes. Clinical Orthopaedics & Related Research 474:10, pages 2221-2229.
Crossref
George C. Hartofilakidis, Kalliopi I. Lampropoulou-Adamidou, Ioannis P. Stathopoulos & John A. Vlamis. (2015) The Outcome of 241 Charnley Total Hip Arthroplasties Performed by One Surgeon 30 to 40Years Ago. The Journal of Arthroplasty 30:10, pages 1767-1771.
Crossref
Aileen Clarke, Ruth Pulikottil-Jacob, Amy Grove, Karoline Freeman, Hema Mistry, Alexander Tsertsvadze, Martin Connock, Rachel Court, Ngianga-Bakwin Kandala, Matthew Costa, Gaurav Suri, David Metcalfe, Michael Crowther, Sarah Morrow, Samantha Johnson & Paul Sutcliffe. (2015) Total hip replacement and surface replacement for the treatment of pain and disability resulting from end-stage arthritis of the hip (review of technology appraisal guidance 2 and 44): systematic review and economic evaluation. Health Technology Assessment 19:10, pages 1-668.
Crossref
Ben J. Burston, Jane H. Wood, James R. Lewis, Gareth H. Prosser, Laura Firth, David J. Wood & Piers J. Yates. (2014) High Failure Rates of the Spectron EF Stem at a Minimum of 10Year's Follow-up. The Journal of Arthroplasty 29:10, pages 1956-1960.
Crossref
P. Mesnil, L. Vasseur, G. Wavreille, C. Fontaine, A. Duquennoy & H. Migaud. (2014) La proth?se de hanche ciment?e m?tal-poly?thyl?ne en 22,2mm est-elle un gold standard?? R?sultats d?une s?rie de 105?proth?ses primaires au recul minimal de 10ans. Revue de Chirurgie Orthop?dique et Traumatologique 100:4, pages 279-283.
Crossref
P. Mesnil, L. Vasseur, G. Wavreille, C. Fontaine, A. Duquennoy & H. Migaud. (2014) Is cemented metal-polyethylene 22.2mm hip arthroplasty a gold standard? Results of a series of 105?primary arthroplasties at a minimum of ten years follow-up. Orthopaedics & Traumatology: Surgery & Research 100:4, pages 369-373.
Crossref
Georgios Digas & Johan Kärrholm. 2014. Bone-Implant Interface in Orthopedic Surgery. Bone-Implant Interface in Orthopedic Surgery 35 54 .
Ren? H.M. ten Broeke, Steffie E.J.M. Harings, Pieter J. Emans, Liesbeth M.C. Jutten, Alfons G.H. Kessels & Rudolph G.T. Geesink. (2013) Randomized Comparison Between the Cemented Scientific Hip Prosthesis and Omnifit: 2-Year DEXA and Minimum 10-Year Clinical Follow-Up. The Journal of Arthroplasty 28:8, pages 1354-1361.
Crossref
Thomas Kadar, Eva Dybvik, Geir Hallan, Ove Furnes & Leif Ivar Havelin. (2012) Head Material Influences Survival of a Cemented Total Hip Prosthesis in the Norwegian Arthroplasty Register. Clinical Orthopaedics and Related Research® 470:11, pages 3007-3013.
Crossref