199
Views
25
CrossRef citations to date
0
Altmetric
Original Article

Wear of the acetabular socket: Comparison of polyacetat and polyethylene

, , &
Pages 193-196 | Published online: 08 Jul 2009

Keep up to date with the latest research on this topic with citation updates for this article.

Read on this site (11)

PaulA. Williams, Kengo Yamamoto, Toshinori Masaoka, Hironobu Oonishi & IanC. Clarke. (2007) Highly Crosslinked Polyethylenes in Hip Replacements: Improved Wear Performance or Paradox?. Tribology Transactions 50:2, pages 277-290.
Read now
Georgios Digas. (2005) New polymer materials in total hip arthroplasty. Acta Orthopaedica 76:sup315, pages 4-82.
Read now
Astor Reigstad & Magne Røkkum. (1992) An intrapelvlc granuloma induced by acetabular cup loosening. Acta Orthopaedica Scandinavica 63:4, pages 465-466.
Read now
. (1992) Role of granulomas in prosthetic loosening. Acta Orthopaedica Scandinavica 63:6, pages 685-685.
Read now
L Ahnfelt, P Herberts, H Malchau & G B J Andersson. (1990) Prognosis of total hip replacement. Acta Orthopaedica Scandinavica 61:sup238, pages 2-26.
Read now
Herbert Franzén & Bengt Mjöberg. (1990) Wear and loosening of the hip prosthesis: A roentgen stereophotogrammetric 3-year study of 14 cases. Acta Orthopaedica Scandinavica 61:6, pages 499-501.
Read now
Acke Ohlin. (1990) Failure of the Christiansen hip: Survival analysis of 265 cases. Acta Orthopaedica Scandinavica 61:1, pages 7-11.
Read now
Acke Ohlin & Lars-Gunnar Kindblom. (1988) The ultrastructure of the tissue surrounding the Christiansen total hip. Acta Orthopaedica Scandinavica 59:6, pages 629-634.
Read now
Bengt Mjoberg. (1986) Loosening of the cemented hip prosthesis. Acta Orthopaedica Scandinavica 57:sup221, pages 3-40.
Read now
Leif Ivar Havelin, Nils Roar Gjerdet, Ole Dankert Lunde, Milan Rait & Einar Sudmann. (1986) Wear of the Christiansen hip prosthesis. Acta Orthopaedica Scandinavica 57:5, pages 419-422.
Read now

Articles from other publishers (14)

Bengt Mjöberg. (2021) Hip prosthetic loosening: A very personal review. World Journal of Orthopedics 12:9, pages 629-639.
Crossref
Einar Sudmann, Knut Rasmus Ramstad & Lars Birger Engesæter. (2013) Christiansens kunstige hofteledd – kva var det som gjekk gale?. Tidsskrift for Den norske legeforening 133:23/24, pages 2513-2517.
Crossref
Toshinori Masaoka, Ian C. Clarke, Kengo Yamamoto, Jiro Tamura, Paul A. Williams, Victoria D. Good, Hiromu Shoji & Atsuhiro Imakiire. (2003) Validation of volumetric and linear wear-measurement in UHMWPE cups—a hip simulator analysis. Wear 254:5-6, pages 391-398.
Crossref
S. M. Kurtz, C. L. Muhlstein & A. A. Edidin. (2000) Surface morphology and wear mechanisms of four clinically relevant biomaterials after hip simulator testing. Journal of Biomedical Materials Research 52:3, pages 447-459.
Crossref
Douglas Danner & Roderick H. Turner. 1999. Revision Total Hip Arthroplasty. Revision Total Hip Arthroplasty 583 598 .
Douglas Danner & Roderick H. Turner. 1999. Revision Total Hip Arthroplasty. Revision Total Hip Arthroplasty 583 598 .
Bengt Mjöberg. (1997) The Theory of Early Loosening of Hip Prostheses. Orthopedics 20:12, pages 1169-1175.
Crossref
S Li & A H Burstein. (1994) Ultra-high molecular weight polyethylene. The material and its use in total joint implants.. The Journal of Bone & Joint Surgery 76:7, pages 1080-1090.
Crossref
Acke Ohlin & G?ran Selvik. (1993) Socket wear assessment. The Journal of Arthroplasty 8:4, pages 427-431.
Crossref
G.W. STACHOWIAK. 1993. Advances in Composite Tribology. Advances in Composite Tribology 509 557 .
Harry A. McKellop, Tord Röstlund & Gary Bradley. (1993) Evaluation of wear in an all-polymer total knee replacement. Part 1: Laboratory testing of polyethylene on polyacetal bearing surfaces. Clinical Materials 14:2, pages 117-126.
Crossref
Sven-Arne Jacobsson, Krister Djerf & Ola Wahlström. (1990) A comparative study between McKee-Farrar and charnley arthroplasty with long-term follow-up periods. The Journal of Arthroplasty 5:1, pages 9-14.
Crossref
A. Ohlin & P.G. Persson. (1989) Failed christiansen total hip arthroplasty. The Journal of Arthroplasty 4:3, pages 207-215.
Crossref
E. B. Mathiesen, J. U. Lindgren, F. P. Reinholt & E. Sudmann. (1987) Tissue reactions to wear products from polyacetal (Delrin®) and UHMW polyethylene in total hip replacement. Journal of Biomedical Materials Research 21:4, pages 459-466.
Crossref

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.