Huy Xuan Ngo, Yunpeng Bai, Jingjing Sha, Shinji Ishizuka, Erina Toda, Rie Osako, Akira Kato, Reon Morioka, Mrunalini Ramanathan, Hiroto Tatsumi, Tatsuo Okui & Takahiro Kanno. (2021) A Narrative Review of u-HA/PLLA, a Bioactive Resorbable Reconstruction Material: Applications in Oral and Maxillofacial Surgery. Materials 15:1, pages 150.
Crossref
Erdogan Utku Ureturk & Aysegul Apaydin. (2018) Does fixation method affects temporomandibular joints after mandibular advancement?. Journal of Cranio-Maxillofacial Surgery 46:6, pages 923-931.
Crossref
Sandra Carolina Cifuentes, Sandra Carolina Cifuentes, Rosario Benavente, Marcela Lieblich, José Luis González-Carrasco & José Luis González-Carrasco. 2017. Handbook of Composites from Renewable Materials. Handbook of Composites from Renewable Materials
109
143
.
Ahmed M.S. Ibrahim, Pieter G.L. Koolen, Kuylhee Kim, Gabe S. Perrone, David L. Kaplan & Samuel J. Lin. (2015) Absorbable Biologically Based Internal Fixation. Clinics in Podiatric Medicine and Surgery 32:1, pages 61-72.
Crossref
Paula R. Beckenkamp, Chung-Wei Christine Lin, Sakina Chagpar, Robert D. Herbert, Hidde P. van der Ploeg & Anne M. Moseley. (2014) Prognosis of Physical Function Following Ankle Fracture: A Systematic Review With Meta-analysis. Journal of Orthopaedic & Sports Physical Therapy 44:11, pages 841-851.
Crossref
Koichiro Ueki, Kohei Marukawa, Akinori Moroi, Megumi Sotobori, Yuri Ishihara, Ran Iguchi, Akihiko Kosaka, Yoshio Nakano, Masatoshi Higuchi, Ryuichi Nakazawa & Hiroumi Ikawa. (2014) Evaluation of overlapped cortical bone area after modified plate fixation with bent plate in sagittal split ramus osteotomy. Journal of Cranio-Maxillofacial Surgery 42:5, pages e210-e216.
Crossref
Koichiro Ueki, Katsuhiko Okabe, Kohei Marukawa, Aya Mukozawa, Akinori Moroi, Mao Miyazaki, Megumi Sotobori, Yuri Ishihara, Kunio Yoshizawa & Kazuhiro Ooi. (2014) Skeletal stability after mandibular setback surgery: Comparison between the hybrid technique for fixation and the conventional plate fixation using an absorbable plate and screws. Journal of Cranio-Maxillofacial Surgery 42:4, pages 351-355.
Crossref
Ji-Young Lee, Young-Kyun Kim, Pil-Young Yun, Nam-Ki Lee, Jong-Wan Kim & Joon-Ho Choi. (2014) Evaluation of Stability After Orthognathic Surgery With Minimal Orthodontic Preparation. Journal of Craniofacial Surgery 25:3, pages 911-915.
Crossref
Taha Ma'ruf, Widowati Siswomihardjo, Marsetyawan HNE Soesatyo & Alva Edy Tontowi. (2013) Polyvinyl alcohol - hydroxyapatite composite reinforced with catgut fibers as biodegradable bone plates. Polyvinyl alcohol - hydroxyapatite composite reinforced with catgut fibers as biodegradable bone plates.
Sushil Rangdal, Daljit Singh, Narendra Joshi, Ashwani Soni & Radheshyam Sament. (2012) Functional outcome of ankle fracture patients treated with biodegradable implants. Foot and Ankle Surgery 18:3, pages 153-156.
Crossref
C. Oprisan, E. Budescu & V. Cotoros. 2012. Advances in Mechanisms Design. Advances in Mechanisms Design
345
350
.
Koichiro Ueki, Katsuhiko Okabe, Mao Miyazaki, Aya Mukozawa, Akinori Moroi, Kohei Marukawa, Kiyomasa Nakagawa & Etsuhide Yamamoto. (2011) Skeletal Stability After Mandibular Setback Surgery: Comparisons Among Unsintered Hydroxyapatite/Poly-L-Lactic Acid Plate, Poly-L-Lactic Acid Plate, and Titanium Plate. Journal of Oral and Maxillofacial Surgery 69:5, pages 1464-1468.
Crossref
Katsuhiko Okabe, Koichiro Ueki, Kohei Marukawa, Aya Mukozawa, Mao Miyazaki & Kiyomasa Nakagawa. (2010) An experimental study of use of absorbable plate in combination with self-setting ?-tricalcium phosphate for orthognathic surgery. Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology 110:5, pages 560-569.
Crossref
Arvo Kukk & Janne T. Nurmi. (2009) A retrospective follow-up of ankle fracture patients treated with a biodegradable plate and screws. Foot and Ankle Surgery 15:4, pages 192-197.
Crossref
Mellick J. Chehade, Lucian B. Solomon, Stuart A. Callary, Sam H. Benveniste, Anthony P. Pohl & Donald W. Howie. (2009) Differentially Loaded Radiostereometric Analysis to Monitor Fracture Stiffness: A Feasibility Study. Clinical Orthopaedics & Related Research 467:7, pages 1839-1847.
Crossref
Jayant S Jainandunsing, Maarten van der Elst & Christian van der Werken. (2009) Bioresorbable fixation devices for musculoskeletal injuries in adults. Cochrane Database of Systematic Reviews.
Crossref
Petteri Väänänen, Arto Koistinen, Janne Nurmi & Reijo Lappalainen. (2008) Biomechanical in vitro evaluation of the effect of cyclic loading on the postoperative fixation stability and degradation of a biodegradable ankle plate. Journal of Orthopaedic Research 26:11, pages 1485-1488.
Crossref
Martin R Downing, P Blair Ashcroft, Alan J Johnstone, Olaf Bach, Suzi Mackenzie & G Patrick Ashcroft. (2008) Assessment of Inducible Fracture Micromotion in Distal Radial Fractures Using Radiostereometry. Journal of Orthopaedic Trauma 22:Supplement 8, pages S96-S105.
Crossref
Johan K??rrholm, Richie H S Gill & Edward R Valstar. (2006) The History and Future of Radiostereometric Analysis. Clinical Orthopaedics and Related Research 448, pages 10-21.
Crossref
Laura Bragonzoni, Alessandro Russo, Mauro Girolami, Ugo Albisinni, Andrea Visani, Nicoletta Mazzotti & Maurilio Marcacci. (2006) The distal tibiofibular syndesmosis during passive foot flexion. RSA-based study on intact, ligament injured and screw fixed cadaver specimens. Archives of Orthopaedic and Trauma Surgery 126:5, pages 304-308.
Crossref
R. Madanat, N. Moritz, S. Larsson & H. T. Aro. (2016) RSA Applications in Monitoring of Fracture Healing in Clinical Trials. Scandinavian Journal of Surgery 95:2, pages 119-127.
Crossref
Takashi Ohkawa, Koushin Nakamura, Moritoshi Itoman, Feng Zhe Jin, Suong Hyu Hyon & Sadami Tsutsumi. (2006) Evaluated of the γ-Ray Radiosterilized Cross-Linked PLLA and PLLA/HA In Vivo. Key Engineering Materials 309-311, pages 1117-1120.
Crossref
Stephen J. Ferguson, Urs Weber, Brigitte von Rechenberg & Joerg Mayer. (2006) Enhancing the mechanical integrity of the implant–bone interface with BoneWelding® technology: Determination of quasi-static interfacial strength and fatigue resistance. Journal of Biomedical Materials Research Part B: Applied Biomaterials 77B:1, pages 13-20.
Crossref
P. Bonnevialle. (2006) Fracturas epifisarias del adulto. EMC - Aparato Locomotor 39:3, pages 1-14.
Crossref
P. Bonnevialle. (2006) Fractures ?piphysaires de l'adulte. EMC - Appareil locomoteur 1:2, pages 1-14.
Crossref
JS Jainandunsing, M van der Elst & CC van der Werken. 1996. Cochrane Database of Systematic Reviews. Cochrane Database of Systematic Reviews.
Michael Yaszemski, Debra Trantolo, Kai-Uwe Lewandrowski, Vasif Hasirci, David Altobelli & Donald WisePetek Korkusuz & Feza Korkusuz. 2003. Biomaterials in Orthopedics. Biomaterials in Orthopedics
1
40
.
Shinsuke Ishii, Jiro Tamura, Taizo Furukawa, Takashi Nakamura, Yoshitaka Matsusue, Yasuo Shikinami & Masaki Okuno. (2003) Long-term study of high-strength hydroxyapatite/poly(L-lactide) composite rods for the internal fixation of bone fractures: A 2-4-year follow-up study in rabbits. Journal of Biomedical Materials Research 66B:2, pages 539-547.
Crossref
L.Russell Alberts, Kenneth O. Phillips, Harold K. Tu, Warren W. Stinson & Andrew Friedman. (2003) A biologic model for assessment of osseous strain patterns and plating systems in the human maxilla. Journal of Oral and Maxillofacial Surgery 61:1, pages 79-88.
Crossref
James A. Rano, Ruth T. Savoy-Moore & Lawrence M. Fallat. (2002) Strength comparison of allogenic bone screws, bioabsorbable screws, and stainless steel screw fixation. The Journal of Foot and Ankle Surgery 41:1, pages 6-15.
Crossref
David B. Thordarson, Michael Samuelson, Lane E. Shepherd, Paul F. Merkle & Jackson Lee. (2016) Bioabsorbable Versus Stainless Steel Screw Fixation of the Syndesmosis in Pronation-Lateral Rotation Ankle Fractures: A Prospective Randomized Trial. Foot & Ankle International 22:4, pages 335-338.
Crossref
Taizo Furukawa, Yoshitaka Matsusue, Tsunoru Yasunaga, Yasuaki Nakagawa, Yasuo Shikinami, Masaki Okuno & Takashi Nakamura. (2000) Bone Bonding Ability of a New Biodegradable Composite for Internal Fixation of Bone Fractures. Clinical Orthopaedics and Related Research 379, pages 247-258.
Crossref
Taizo Furukawa, Yoshitaka Matsusue, Tsunoru Yasunaga, Yasuaki Nakagawa, Yoshifumi Okada, Yasuo Shikinami, Masaki Okuno & Takashi Nakamura. (2000) Histomorphometric study on high-strength hydroxyapatite/poly(L-lactide) composite rods for internal fixation of bone fractures. Journal of Biomedical Materials Research 50:3, pages 410-419.
Crossref
Taizo Furukawa, Yoshitaka Matsusue, Tsunoru Yasunaga, Yasuo Shikinami, Masaki Okuno & Takashi Nakamura. (2000) Biodegradation behavior of ultra-high-strength hydroxyapatite/poly (l-lactide) composite rods for internal fixation of bone fractures. Biomaterials 21:9, pages 889-898.
Crossref
R. Hoffmann, A. Weiler, H.-J. Helling & K. E. Rehm. 1998. Biodegradierbare Implantate und Materialien. Biodegradierbare Implantate und Materialien
238
251
.
A. Weiler, H.-J. Helling, U. Kirch & K. E. Rehm. 1998. Biodegradierbare Implantate und Materialien. Biodegradierbare Implantate und Materialien
146
159
.
LOWELL H. GILL, DAVID F. MARTIN, JAMES M. COUMAS & GARY M. KIEBZAK. (1997) Fixation with Bioabsorbable Pins in Chevron Bunionectomy*. The Journal of Bone & Joint Surgery 79:10, pages 1510-8.
Crossref
David B. Thordarson, Thomas P. Hedman, Dominic Gross & George Magre. (2016) Biomechanical Evaluation of Polylactide Absorbable Screws Used for Syndesmosis Injury Repair. Foot & Ankle International 18:10, pages 622-627.
Crossref
C. Gatzka, H. J. Helling, A. Prokop, R. Fischbach & K. E. Rehm. 1997. 61. Jahrestagung. 61. Jahrestagung
766
769
.
O. M. B??stman. (1996) Metallic or Absorbable Fracture Fixation Devices. Clinical Orthopaedics & Related Research 329, pages 233-239.
Crossref