218
Views
0
CrossRef citations to date
0
Altmetric
Original Articles

Impactor collection efficiencies can modify the uncertainty of multiply charged particles in optical extinction measurements

ORCID Icon, ORCID Icon, ORCID Icon, ORCID Icon & ORCID Icon
Pages 562-576 | Received 19 Dec 2022, Accepted 06 Mar 2023, Published online: 10 Apr 2023
 

Abstract

The complex distribution of particle charge states resulting from neutralization processes by radioactive or soft X-ray charge neutralizers is a well-documented problem in aerosol science. Here, we demonstrate that non-idealities in the collection efficiency of an impactor allows for the transmission of an unexpected population of multiply charged particles by a differential mobility analyzer that can bias optical measurements. The extinction cross sections (Cext) of ammonium sulfate particles were quantified using cavity ring-down spectroscopy and particle counting. Particles were selected by electrical mobility (i.e., a metric of particle size) using a differential mobility analyzer (DMA) or electrical mobility and mass selected by a tandem DMA and aerosol particle mass analyzer (APM), respectively, to elucidate multiple charging artifacts. Measured Cext exhibited statistically significant differences at particle sizes near the impactor cut point implying that these multiply charged particles should not be present and could not be confirmed by parallel size distribution measurements. Additionally, comparison of Cext with Mie theory demonstrates that misclassification of the multiply charged particles can give rise to numerically accurate results. To understand these observations, the collection efficiency (CE) of four impactors from similar electrostatic classifiers was investigated. From these measurements, it was determined that the nominal and actual diameters of the impactors differed by −0.5% (457 μm vs. (455 ± 1) μm, respectively (uncertainty is 1σ standard deviation)) but the average Stk50 (the Stokes number at the cut-point, D50) values differed by ≈ 23% (0.23 vs. 0.18 ± 0.01, respectively). The measured CE as a function of √Stk (a metric of particle aerodynamic size) exhibits a long tail toward higher √Stk values, allowing for transmission of the larger and multiply charged particles observed in the optical measurements. These measurements highlight the utility of using orthogonal, spectroscopic methods to quantify the presence of multiply charged particles.

Copyright © 2023 American Association for Aerosol Research

Graphical Abstract

Editor:

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 61.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 165.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.