Abstract
In this paper, we consider a controller failure time analysis problem for a class of symmetric linear time-invariant (LTI) systems controlled by a pre-designed symmetric static output feedback controller. We assume that the controller fails from time to time due to a physical or purposeful reason, and we analyse stability and disturbance attenuation properties of the entire system. Our aim is to find conditions concerning controller failure time, under which the system's stability and
disturbance attenuation properties are preserved to a desired level. For both stability and
disturbance attenuation analysis, we show that if the unavailability rate of the controller is smaller than a specified constant, then global exponential stability of the entire system and a reasonable
disturbance attenuation level is achieved. The key point is to establish a common quadratic Lyapunov-like function for the entire system in two different situations.
Acknowledgements
The authors would like to thank Prof. Xinkai Chen of Kinki University, Prof. Shigemasa Takai and Prof. Kazunori Yasuda of Wakayama University for their valuable comments.