52
Views
4
CrossRef citations to date
0
Altmetric
Original Articles

Can high-performance liquid chromatography coupled with fluorescence detection under all conditions be regarded as a sufficiently conclusive confirmatory method for B-group substances?

, , , &
Pages 1149-1156 | Received 01 Dec 2005, Accepted 21 Jun 2006, Published online: 11 Feb 2011
 

Abstract

Commission Decision 2002/657/EC requires confirmatory analysis of B-group compounds when detected at levels above the permitted limit. In contrast to banned substances, for B-group substances, the use of mass spectrometric techniques is not obligatory and several techniques including liquid chromatography (LC)-ultraviolet light (UV) on two different LC columns and (single-column) high-performance liquid chromatography (HPLC)-fluorescence (Flu) are considered to deliver sufficient evidence for the identification of the detected substance. The analysis of sodium salicylate in animal drinking water collected at poultry farms is presented here as an example to show that even in a simple matrix such as animal drinking water, fluorescence detection in some cases may provide inadequate specificity. Of 50 samples analysed by LC-Flu, 18 tested positive for sodium salicylate. However, only in one sample was the presence of the analyte confirmed with mass spectrometric detection; the others were blank. Consequently, the LC-Flu results obtained were false-non-compliant for sodium salicylate. A second case concerning the analysis of avermectins in milk by HLPC-Flu is briefly described. For a number of samples analysed in the framework of a proficiency test, false non-compliant results for emamectin were reported due to a background interference sometimes present that practically co-eluted with the analyte. The observed retention time difference (1%) was well below the criterion (2.5%) specified in Commission Decision 2002/657/EC. Considering the impact of positive findings on individual farmers as well as on trade, product image and food safety perception by the consumer, it is concluded that also for B-group substances false-non-compliant results should be avoided whenever possible. This is especially important when the results are treated as and are expected to have the same repercussions as in the case of banned A-group substances. In these circumstances, only results obtained by mass spectrometry should be considered for confirmatory purposes.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 61.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 799.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.