Mass Spectrometry-Based Intraoperative Tumor Diagnostics

, , &
Article: FSO373 | Received 21 Sep 2018, Accepted 08 Jan 2019, Published online: 07 Mar 2019

Figures & data

Table 1. Overview about publications analyzing cancer specimen with mass spectrometric tools coupled to intraoperative sampling mechanisms.

Figure 1. Schematic figure of mass spectrometry based methods for intraoperative cancer diagnosis (left) with corresponding examples of mass spectra (right).

(A) Desorption electrospray ionization. Left: Schematic representation of desorption electrospray ionization. Under the influence of high voltage a methanol-water solution is sprayed on the sample surface, dissolving desorbed ions to be transferred in the atmospheric inlet of the mass spectrometer. Parameters like voltage, gas and liquid flow rate can be set. Right: Average lipid profile spectrum for all pixels images used for chemical prediction. Reproduced with permission from [Citation45]. (B) iKnife. Left: Schematic illustration of rapid evaporative mass spectrometry coupled to eligible surgical devices. Surgical ion source and ion transfer setups for rapid evaporative mass spectrometry experiments are demonstrated using an endoscope, monopolar electrosurgery or commercially available bipolar electrosurgery. The aerosol is aspirated by an air jet pump through a teflon tube with a maximum of 3 m length. By histological validation and Principal Component Analysis, in a second run the recognition software differentiates cancer and normal tissue by comparing signal intensities in the recorded mass spectra. Most of the signals in the spectra represent lipid ions. Right: Mean spectral intensity for cancer and normal tissues during cutting. Reproduced with permission from [Citation50]. (C) MasSpec pen. Left: A handheld device (MasSpec pen) is positioned on the sample surface and through the inlet channel a water droplet is exposed for 1 s to extract molecules from the tissue surface. Then, the channel is closed and after 2 s, gas inlet is opened to transport the water droplet (volume controlled by a syringe pump) via polytetrafluorethylen (PTFE) tubing driven by vacuum into the mass spectrometer. The system is triggered by a foot pedal connected to an integrated mass spectrometer inlet. Right: Representative negative ion mode mass spectra show distinct molecular profiles from normal (average of n = 3 mass spectra) and tumor (average of n = 3 mass spectra) tissues [Citation53]. (D) Picosecond infrared laser. Left: Current instrument for sampling of tissue with picosecond infrared laser. For cryopreserved samples, the specimen stage is cooled down to -10°C, preventing thawing during laser irradiation. The ablation chamber is sealed to capture the aerosol in its complete volume, achieved by its architecture generating a laminar flow. The aerosol is trapped through PTFE-tubing as a frozen (cooling trap) or dry (glass fiber filter) condensate within seconds. Instead of the free laser beam a fiber can be utilized to adjust and operate flexibly. Right: Negative ion mode mass spectrum from picosecond infrared laser condensate of porcine thalamus (upper) and cerebral cortex (lower) directly infused into the MS without sample preparation.

HV: High voltage; IPA: Isopropyl alcohol; PIRL: Picosecond infrared laser.

Figure 1.  Schematic figure of mass spectrometry based methods for intraoperative cancer diagnosis (left) with corresponding examples of mass spectra (right).(A) Desorption electrospray ionization. Left: Schematic representation of desorption electrospray ionization. Under the influence of high voltage a methanol-water solution is sprayed on the sample surface, dissolving desorbed ions to be transferred in the atmospheric inlet of the mass spectrometer. Parameters like voltage, gas and liquid flow rate can be set. Right: Average lipid profile spectrum for all pixels images used for chemical prediction. Reproduced with permission from [Citation45]. (B) iKnife. Left: Schematic illustration of rapid evaporative mass spectrometry coupled to eligible surgical devices. Surgical ion source and ion transfer setups for rapid evaporative mass spectrometry experiments are demonstrated using an endoscope, monopolar electrosurgery or commercially available bipolar electrosurgery. The aerosol is aspirated by an air jet pump through a teflon tube with a maximum of 3 m length. By histological validation and Principal Component Analysis, in a second run the recognition software differentiates cancer and normal tissue by comparing signal intensities in the recorded mass spectra. Most of the signals in the spectra represent lipid ions. Right: Mean spectral intensity for cancer and normal tissues during cutting. Reproduced with permission from [Citation50]. (C) MasSpec pen. Left: A handheld device (MasSpec pen) is positioned on the sample surface and through the inlet channel a water droplet is exposed for 1 s to extract molecules from the tissue surface. Then, the channel is closed and after 2 s, gas inlet is opened to transport the water droplet (volume controlled by a syringe pump) via polytetrafluorethylen (PTFE) tubing driven by vacuum into the mass spectrometer. The system is triggered by a foot pedal connected to an integrated mass spectrometer inlet. Right: Representative negative ion mode mass spectra show distinct molecular profiles from normal (average of n = 3 mass spectra) and tumor (average of n = 3 mass spectra) tissues [Citation53]. (D) Picosecond infrared laser. Left: Current instrument for sampling of tissue with picosecond infrared laser. For cryopreserved samples, the specimen stage is cooled down to -10°C, preventing thawing during laser irradiation. The ablation chamber is sealed to capture the aerosol in its complete volume, achieved by its architecture generating a laminar flow. The aerosol is trapped through PTFE-tubing as a frozen (cooling trap) or dry (glass fiber filter) condensate within seconds. Instead of the free laser beam a fiber can be utilized to adjust and operate flexibly. Right: Negative ion mode mass spectrum from picosecond infrared laser condensate of porcine thalamus (upper) and cerebral cortex (lower) directly infused into the MS without sample preparation.HV: High voltage; IPA: Isopropyl alcohol; PIRL: Picosecond infrared laser.

Table 2. Overview of mass spectrometry-based methods for intraoperative cancer diagnosis.