353
Views
16
CrossRef citations to date
0
Altmetric
ATOMIC SPECTROSCOPY

Analytical Method Validation and Determination of Iron and Phosphorus in Vegetable Oil by Inductively Coupled Plasma–Mass Spectrometry with Microwave Assisted Digestion

, , , &
Pages 1774-1788 | Received 15 Jun 2017, Accepted 29 Sep 2017, Published online: 26 Mar 2018
 

ABSTRACT

Inductively coupled plasma–mass spectrometric determination of iron and phosphorus in three vegetable oils (soybean, coconut, and sunflower) was validated for the intermediate precision, trueness, linearity, and quantitation limit. The overall precision (n = 5) for the analytes, which were above the method’s practical limit of quantification, were less than 2% relative standard deviation and the same as the laboratory control, NIST-SRM-1849a. Trueness was demonstrated with spike recoveries of the analytes in all vegetable oils at limit of quantification-level spiking. Although good linearity (regression coefficient greater than 0.9990) obtained, the recovery of phosphorus (156–189%) was high, possibly due to oil matrix enhancement, compared to the recovery of iron (91–106%). For soybean oil, sunflower oil, coconut oil, and medium chain triglycerides, the concentrations (mg/kg) of iron were in the range of 0.10–1.47, 0.09–1.51, 0.20–0.35, and 0.09–0.13, respectively. Similarly, phosphorus concentrations (mg/kg) were in the range of 0.77–124.56, 0.49–125.57, 0.52–9.72, and 0.85–11.90, respectively. The study achieved considerably low instrument-based practical limits of quantification for iron (0.005 mg/kg) and phosphorus (0.05 mg/kg), which are fivefold lower than the AOAC Official Method 2015.06. The high instrument sensitivity and selectivity of the method allow the determination of trace levels of iron and phosphorus in vegetable oils with good precision and trueness.

Acknowledgment

Anjaneyulu Pendem, Research Scientist, Syngene Regional Lab, Bangalore, India is greatly acknowledged for reviewing the manuscript before submission to publisher.

Declaration of conflict of interest

We wish to confirm that there are no known conflicts of interest associated with this publication. We confirm that the manuscript has been read and approved by all named authors. We further confirm that the order of authors listed in the manuscript has been approved by all of us.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 61.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 768.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.