ABSTRACT
The effect of variation in open area ratio (β) in a multi-V rib roughened Single-Pass Solar Air Heater (SPSAH) is analyzed in this work. Fixing values of other parameters, such as open area ratio (β) and relative roughness width (W/w), were studied with a certain range of Reynolds number (Re) ranging from 2000 to 18000. The improvement in Nusselt number ratio (Nu/Nus) and thermo-hydraulic performance (THPP) and the decline in duct friction ratio (f/fs) support the application of perforation. The empirical correlations of Nu and f are also generated with ±12% and ±7.5% accuracy.
Graphical Abstract
![](/cms/asset/63896348-8f8c-4967-a548-9ba4246f4991/ueht_a_2064940_uf0001_oc.jpg)
Acknowledgments
The authors acknowledge ME Department, College of Engineering Roorkee (COER), Roorkee, India for supporting this research work and providing facilities to develop setup and conducting experiments on their facility.
Disclosure statement
No potential conflict of interest was reported by the authors.